Aqualisa Midas 100 Скачать руководство пользователя страница 23

23

User guide - Shower head

NEVER ATTEMPT TO MAKE ANY ADJUSTMENT TO THE SHOWER HEAD BY PULLING ON THE SHOWER HOSE.

1. To select the preferred height for the shower head, 

dependent on the system purchased, depress the 
handset holder button or levers fully to enable the 
slider to be moved up or down the rail. 

Your Midas shower system should be cleaned using only a soft cloth and washing up liquid.

! DO NOT USE ABRASIVE CLEANERS.

To reduce the need for chemical descaling in hard water areas, your shower head incorporates a ‘clear flow’ system, whereby any
scale build up can be broken down by gently rubbing the flexible tips of the jets during use. This procedure should be completed 
regularly, as often as once a week in some hard water areas, as scale build up can affect the spray pattern and cause the shower 
to perform poorly. Failure to descale the shower head can affect the internal seals and may affect the warranty.

Should chemical descaling of the head become necessary, remove the shower head fully and immerse in a mild proprietary 
descalent.

IT IS IMPERATIVE THAT DESCALING IS CARRIED OUT STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS 
INSTRUCTIONS. SUBSTANCES THAT ARE NOT SUITABLE FOR PLASTICS AND ELECTROPLATED SURFACES MUST 
NOT BE USED.

2. Angular adjustment is made by carefully but firmly pulling forwards or 

pushing back the shower head against the knuckle in the holder. 

3. To select the desired spray pattern rotate the shower spray plate clockwise or 

anti-clockwise. 

Cleaning & maintenance

Midas 100

Midas 200

Midas 300

Midas 100/200

Midas 300

Midas 100/200

Midas 300

 

 

Содержание Midas 100

Страница 1: ...Midas Thermostatic exposed shower valve and bath shower mixer systems Installation guide...

Страница 2: ......

Страница 3: ...iler systems p 6 Typical water systems p 7 System components p 9 Valve installation instructions p 12 Midas range exposed valves p 12 Midas range bath shower mixer p 13 Shower head installation p 16 M...

Страница 4: ...ply Regulations The Midas range is designed for domestic use only Product specification Midas 100 shower valve product is suitable for gravity stored gravity boosted balanced high pressure and combina...

Страница 5: ...of 3 bar is recommended It should be noted that daytime pressures approaching 8 bar can rise above the stated maximum overnight A suitable PRV is available from Aqualisa The Midas product range is no...

Страница 6: ...inder manufacturers pressure limiting valve where supplied and the hot supply from the nearest convenient draw off point Account must be taken of pressure drops that may occur when other draw off poin...

Страница 7: ...pical pumped system installation suitable for use with Midas 100 and the Midas 200 300 low pressure shower valve Typical gravity system installation suitable for use with Midas 100 and the Midas 200 3...

Страница 8: ...use with Midas 100 and the Midas high pressure product range Typical thermal storage unit system installation suitable for use with Midas 100 and the Midas high pressure product range Typical UHW sys...

Страница 9: ...Components Midas 100 Exposed shower valve with adjustable height head Bath shower mixer with adjustable height head 9...

Страница 10: ...Components Midas 200 Exposed shower valve with adjustable height head Bath shower mixer with adjustable height head Flow regulators for use with combination boilers 10...

Страница 11: ...Components Midas 300 Exposed shower valve with adjustable height head Bath shower mixer with adjustable height head Flow regulators for use with combination boilers 11...

Страница 12: ...ar valves onto a finished wall surface using 15mm concealed pipe work If required fit the bar valve fixing accessory following the relevant installation instructions provided with the accessory kit an...

Страница 13: ...t you have all the necessary components shown overleaf before commencing installation Failure to install the product in accordance with these instructions may adversely affect the warranty terms and c...

Страница 14: ...e separately from Aqualisa customer services supplied with part no 525301 or complete with the easy fit fixing bracket If required apply a thin bead of mastic to the rear of the cover plates Place the...

Страница 15: ...and offer the assembly into position onto the bath 3 Place the back nuts onto the tap tails and secure the assembly to the underside of the bath Deck mount installation 5 Turn on the supplies to the b...

Страница 16: ...sed 5 Fit the rail into the rail end bodies ensuring the indents in the rail are facing the finished wall surface Midas 100 adjustable height head installation 4 Current water supply regulations state...

Страница 17: ...der 8 If required optional outlet flow regulators can be purchased from the Aqualisa customer helpline on 01959 560010 Fit the relevant flow regulator into the brass housing ensuring the O ring faces...

Страница 18: ...the handset should not be allowed to pass a point 25mm above the spill over level of the bath or shower tray If this cannot be achieved the hose must be passed through the gel hook which has also been...

Страница 19: ...0010 Fit the relevant flow regulator into the brass housing ensuring the O ring faces the incoming flow Connect the flow regulator assembly to the valve outlet ensuring the hose washer is correctly fi...

Страница 20: ...t holder whilst keeping the slider button depressed 4 Current water supply regulations state the handset should not be allowed to pass a point 25mm above the spill over level of the bath or shower tra...

Страница 21: ...aint 11 Ensuring the hose is in the correct position offer the hose onto the handset Push the handset onto the hose to lock the anti kink swivel connector and secure the handset to the hose Once tight...

Страница 22: ...bath spout When the temperature lever knob on the right of the valve when viewed from the front has the maximum temperature override button at the top of the knob the valve is in the mid blend positio...

Страница 23: ...as often as once a week in some hard water areas as scale build up can affect the spray pattern and cause the shower to perform poorly Failure to descale the shower head can affect the internal seals...

Страница 24: ...nge a replacement 2 Turn the temperature control knob to the mid blend position with the button at the top of the knob 3 Carefully remove the end cover cap using a small flat bladed screwdriver if nec...

Страница 25: ...ater pressure exceeds 10 bar install a pressure reducing valve PRV in accordance with the installation guide Airlock in the hot water supply Water temperature swings regularly between hot and cold Flo...

Страница 26: ...26 Notes...

Страница 27: ...enquiries aqualisa co uk Republic of Ireland Sales enquiries 01 864 3363 Service enquiries 01 844 3212 Please note that calls may be recorded for training and quality purposes The company reserves th...

Страница 28: ...Pdf Supplied By http www plumbworld co uk...