Aqualisa Midas 100 Скачать руководство пользователя страница 12

Midas exposed valves

2

If required, apply jointing tape to the threads and fit the eccentric elbow connectors
sufficiently to achieve a water tight seal, terminating at 150mm centres to suit the
exposed valve inlets.

12

!

!

In addition to the guide below it is essential that the written instructions overleaf are read and understood and
that you have all the necessary components (shown overleaf) before commencing installation. Failure to install the
product in accordance with these instructions may adversely affect the warranty terms and conditions. Do not
undertake any part of this installation unless you are competent to do so. Prior to starting ensure that you are
familiar with the necessary plumbing regulations required to install the product correctly and safely.

Bar valve fixing accessories are available separately. The MD300EFB is a first fix 
fixing bracket. If using the MD300EFB bracket, ensure sufficient threads are left 
from the finished wall surface, after the cover plates have been fitted, to ensure 
adequate purchase for the exposed valve. 

The BAR001FIX bar valve fixing kit provides a method of surface siting exposed 
bar valves onto a finished wall surface, using 15mm concealed pipe work. 

If required, fit the bar valve fixing accessory following the relevant installation 
instructions provided with the accessory kit and proceed to step 6 below.

The exposed valve and fixing bracket assembly MUST NOT be used as a grab 
rail support method.

   

 

 

 

Eccentric elbows are provided to allow for inlet pipework adjustment between 130mm – 170mm centres. Construct 
suitable connections terminating in ½”BSP female fittings.
When using the eccentric elbows provided we recommend leaving sufficient threads from the  finished wall 
surface, after the cover plates have been fitted, to ensure adequate purchase for the exposed valve.
If using alternative fixings please refer to the installation instructions provided to ensure adequate threads are
left to connect the exposed valve after the cover plates have been fitted to the finished wall surface.

1

!

3

Ensuring adequate provision to allow the water to discharge safely to waste, turn on the supplies to flush the system
through. Attach pressure test equipment and pressure test the system in accordance with Water Supply Regulations.

4

Ensure the ¾” supply connections are temporarily capped to prevent any dirt or dust ingress into the pipe work during the
making good process. Remove the caps prior to connecting the shower valve. 

 

 

Содержание Midas 100

Страница 1: ...Midas Thermostatic exposed shower valve and bath shower mixer systems Installation guide...

Страница 2: ......

Страница 3: ...iler systems p 6 Typical water systems p 7 System components p 9 Valve installation instructions p 12 Midas range exposed valves p 12 Midas range bath shower mixer p 13 Shower head installation p 16 M...

Страница 4: ...ply Regulations The Midas range is designed for domestic use only Product specification Midas 100 shower valve product is suitable for gravity stored gravity boosted balanced high pressure and combina...

Страница 5: ...of 3 bar is recommended It should be noted that daytime pressures approaching 8 bar can rise above the stated maximum overnight A suitable PRV is available from Aqualisa The Midas product range is no...

Страница 6: ...inder manufacturers pressure limiting valve where supplied and the hot supply from the nearest convenient draw off point Account must be taken of pressure drops that may occur when other draw off poin...

Страница 7: ...pical pumped system installation suitable for use with Midas 100 and the Midas 200 300 low pressure shower valve Typical gravity system installation suitable for use with Midas 100 and the Midas 200 3...

Страница 8: ...use with Midas 100 and the Midas high pressure product range Typical thermal storage unit system installation suitable for use with Midas 100 and the Midas high pressure product range Typical UHW sys...

Страница 9: ...Components Midas 100 Exposed shower valve with adjustable height head Bath shower mixer with adjustable height head 9...

Страница 10: ...Components Midas 200 Exposed shower valve with adjustable height head Bath shower mixer with adjustable height head Flow regulators for use with combination boilers 10...

Страница 11: ...Components Midas 300 Exposed shower valve with adjustable height head Bath shower mixer with adjustable height head Flow regulators for use with combination boilers 11...

Страница 12: ...ar valves onto a finished wall surface using 15mm concealed pipe work If required fit the bar valve fixing accessory following the relevant installation instructions provided with the accessory kit an...

Страница 13: ...t you have all the necessary components shown overleaf before commencing installation Failure to install the product in accordance with these instructions may adversely affect the warranty terms and c...

Страница 14: ...e separately from Aqualisa customer services supplied with part no 525301 or complete with the easy fit fixing bracket If required apply a thin bead of mastic to the rear of the cover plates Place the...

Страница 15: ...and offer the assembly into position onto the bath 3 Place the back nuts onto the tap tails and secure the assembly to the underside of the bath Deck mount installation 5 Turn on the supplies to the b...

Страница 16: ...sed 5 Fit the rail into the rail end bodies ensuring the indents in the rail are facing the finished wall surface Midas 100 adjustable height head installation 4 Current water supply regulations state...

Страница 17: ...der 8 If required optional outlet flow regulators can be purchased from the Aqualisa customer helpline on 01959 560010 Fit the relevant flow regulator into the brass housing ensuring the O ring faces...

Страница 18: ...the handset should not be allowed to pass a point 25mm above the spill over level of the bath or shower tray If this cannot be achieved the hose must be passed through the gel hook which has also been...

Страница 19: ...0010 Fit the relevant flow regulator into the brass housing ensuring the O ring faces the incoming flow Connect the flow regulator assembly to the valve outlet ensuring the hose washer is correctly fi...

Страница 20: ...t holder whilst keeping the slider button depressed 4 Current water supply regulations state the handset should not be allowed to pass a point 25mm above the spill over level of the bath or shower tra...

Страница 21: ...aint 11 Ensuring the hose is in the correct position offer the hose onto the handset Push the handset onto the hose to lock the anti kink swivel connector and secure the handset to the hose Once tight...

Страница 22: ...bath spout When the temperature lever knob on the right of the valve when viewed from the front has the maximum temperature override button at the top of the knob the valve is in the mid blend positio...

Страница 23: ...as often as once a week in some hard water areas as scale build up can affect the spray pattern and cause the shower to perform poorly Failure to descale the shower head can affect the internal seals...

Страница 24: ...nge a replacement 2 Turn the temperature control knob to the mid blend position with the button at the top of the knob 3 Carefully remove the end cover cap using a small flat bladed screwdriver if nec...

Страница 25: ...ater pressure exceeds 10 bar install a pressure reducing valve PRV in accordance with the installation guide Airlock in the hot water supply Water temperature swings regularly between hot and cold Flo...

Страница 26: ...26 Notes...

Страница 27: ...enquiries aqualisa co uk Republic of Ireland Sales enquiries 01 864 3363 Service enquiries 01 844 3212 Please note that calls may be recorded for training and quality purposes The company reserves th...

Страница 28: ...Pdf Supplied By http www plumbworld co uk...