Quartz Digital exposed with adjustable head

installation instructions

Page 7

Installation instructions

This product must be installed by a competent person in accordance with the

relevant Water Supply Regulations.

In addition to the guide below, it is essential that the written instructions

overleaf are read and understood and that you have all the necessary

components (shown overleaf) before commencing installation.

The Quartz Digital shower system is supplied with universal fixings intended

to secure it to a suitable wall.

!

!

90mm

445m

m

270m

m

350mm

265m

m

70mm

To ensure safe operation and installation of this product, the processor MUST be

installed in one of the orientations shown.

1

Isolation valves are supplied with the Digital

processor and must be fitted on both inlets and

the blended water outlet. All pipe work should

be run in 15mm pipe. All pipe work should be

supported. For externally pumped gravity fed

installations, 22mm pipe work should be run

as close to the processor as possible before

reducing down to 15mm.

2

The inlet supply centres are 48mm. The inlet supply centres deviate from

EN1111 and EN1287, but are deemed to be a special case. Please note arrow

on isolation valve to indicate direction of flow.

Compression fittings should not be used on the inlet and outlet spigots and

may affect the warranty if fitted.

!

!

Содержание iSys

Страница 1: ...Quartz Digital Exposed with adjustable height head Installation guide TM Quartz Digital exposed with adjustable head installation instructions Page 1 ...

Страница 2: ...Quartz Digital exposed with adjustable head installation instructions Page 2 Quartz Digital exposed Quartz Digital exposed with adjustable head ...

Страница 3: ...Quartz Digital exposed with adjustable head installation instructions Page 3 Components HP Combi Literature not shown Components Gravity pumped Literature not shown ...

Страница 4: ...ay with the product Cleaning and user maintenance shall not be made by children without supervision This system should be installed so that other taps or appliances operated elsewhere within the premises do not significantly affect the flow The shower must not be used with a hot water supply temperature over 65 C The processor is supplied factory pre set at a maximum temperature of 45 C The maximu...

Страница 5: ...llons The capacity of the hot water cylinder must be capable of meeting anticipated demand Installation of Digital HP Combi processor for balanced high pressure and unvented systems combination boiler systems and separately pumped gravity systems Pressures The Quartz Digital HP Combi shower system is designed to operate up to a maximum static pressure of 700kPa 7 bar 100psi Where pressures are lik...

Страница 6: ...the tube insert must not increase the tube diameter or extend the cut off length by more than 2mm THESE FITTINGS ARE NOT SUITABLE FOR STAINLESS STEEL TUBE COMPRESSION FITTINGS MUST NOT BE USED Pipe sizing Long pipe runs on both inlet and outlet will reduce the flow rate at the shower head 22mm pipe work should be used on inlets and reduce down to 15mm as close to the valve as possible to reduce pr...

Страница 7: ...nsure safe operation and installation of this product the processor MUST be installed in one of the orientations shown 1 Isolation valves are supplied with the Digital processor and must be fitted on both inlets and the blended water outlet All pipe work should be run in 15mm pipe All pipe work should be supported For externally pumped gravity fed installations 22mm pipe work should be run as clos...

Страница 8: ... in the airing cupboard or behind a screwed bath panel if more convenient If siting in the roof space ensure that freezing cannot occur and that no insulation material is placed under or over the processor Please refer to the system layout diagrams 3 THE PROCESSOR MUST BE SITED IN A POSITION THAT IS SAFELY ACCESSIBLE FOR SERVICING AND COMMISSIONING PURPOSES WHEN FITTED IN THE LOFT SPACE THE ROUTE ...

Страница 9: ...ol is at the desired height the rail is vertical and that there is adequate working clearance above the top of the rail in the roof space 9 Temporarily slide the gel hook up the rail ensuring it is positioned higher than the lower fixing bracket assembly 10 Locate a suitable entry point into the ceiling for the riser rail avoiding joists and services 7 The centre of the riser rail stands 45mm from...

Страница 10: ...and the handset holder are below the rail wall bracket 15 Ensuring the rail assembly has been passed through the hole in the ceiling and is at the desired height mark the screw holes and remove the fixing bracket 13 Prepare suitable fixings and slide the fixing bracket back over the rail onto the support pillar Secure to the wall using the screws provided 14 Slide the fixing bracket over the rail ...

Страница 11: ...he ceiling to cover the entry hole 18 The ceiling plate cannot be sited against an uneven surface If there is coving or an alternative obstruction please ensure the entry hole is neat and unobtrusive otherwise the inner tube could be visible within the showering area If the ceiling height is over 2 4m 8ft a Digital riser rail extension kit will be required Contact our Customer Service Department t...

Страница 12: ... THE MINIMUM AMOUNT OF ELBOWS TO MAXIMISE FLOW RATES WE RECOMMEND USING COPPER PIPE WITH THE MINIMUM AMOUNT OF ELBOWS BEFORE ANY ELECTRICAL ADJUSTMENT IS ATTEMPTED THE ELECTRICITY SUPPLY MUST BE TURNED OFF AT THE MAINS SWITCH ELECTRICAL INSTALLATION MAY ONLY BE CARRIED OUT BY A QUALIFIED PERSON Connect the processor power lead to a double pole 3amp switched fused spur incorporated in the wiring ci...

Страница 13: ...r Digital diverter This can be accessed by carefully snapping and removing the entry pillar and connecting the cable as described above Unscrew the single fixing on top of the processor box and then carefully tilt the lid up and off the location lugs and pull the lid clear 21 Connect the power to the processor and press the Start stop button on the controller to turn the shower on Ensuring the hos...

Страница 14: ...I PROCESSORS ON BALANCED HP SYSTEMS HP Combi Digital processors fitted to balanced high pressure systems may be set to NORMAL HP or for water economy ECO modes HP COMBI PROCESSORS ON COMBINATION BOILER SYSTEMS For HP Combi Digital processors installed on combi boiler systems for optimum performance we recommend setting the flow rate to the COMBI mode 26 N B The ECO flow rate mode should not be sel...

Страница 15: ...control as indicated When the temperature has been set to the desired position carefully replace the Digital processor lid and secure the fixing hand tight only 28 Site conditions can affect temperature settings installer to adjust as required ALL COPPER PIPE WORK MUST BE CROSS BONDED AND CONNECTED TO A RELIABLE EARTHING POINT Re instate the electricity supply to the Digital processor Press the St...

Страница 16: ...l enquiries aqualisa co uk Republic of Ireland Sales enquiries 01 864 3363 Service enquiries 01 844 3212 Part No 700994 Issue 01 Jan 14 Please note that calls may be recorded for training and quality purposes The company reserves the right to alter change or modify the product specifications without prior warning Registered Trademark Aqualisa Products Limited ...

Страница 17: ...r Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps Grundfos Shower Pumps ...

Отзывы: