20
Commissioning – Colt concealed
The Colt concealed valve is pre-set to a safe maximum shower temperature. During use, the action of the stop
button may be overridden by depressing it as the temperature control is rotated. Should it be necessary to reset
the maximum temperature position please observe the following procedures.
1. Ensure that the hot water system is at normal maximum temperature.
2. Turn the temperature control lever to the full cold position (9 o’clock).
3. Carefully remove the on/off knob.
4. Remove the temperature control lever screws and pull the lever clear.
5. Carefully remove the red pre-set override ring and re-set in the appropriate direction to increase (clockwise) or
decrease (anti-clockwise) the temperature where the override button needs to be pressed.
6. Depress the stop button and replace the temperature lever in the full cold position. Push the on/off knob into
position fully home, but do not secure with the small screw at this stage.
7. Test the shower by turning it on and slowly increasing the temperature, at the selected point, the button
should pop up and prevent further movement.
8. Repeat the above process if the maximum temperature stop button needs further adjustment.
9. Follow steps 19 to 21 on page 13 to re-fit the temperature lever and on/off knob.
Should the on/off knob need to be removed at any time, turn the knob fully clockwise to the off position.
Carefully depress the left hand side of the badge using a suitable tool taking care not to damage the badge
or the surrounding plated surfaces of the on off knob. The right hand side of the badge will lift clear of the
recess enabling you to remove the badge, giving you access to the small screw fixing the knob in place.
Remove the screw and pull the knob clear.
Should unacceptable damage to the badge occur when removing it from the recess, please contact Aqualisa
customer services who will send a free of charge replacement.
Commissioning – Colt exposed
The Colt exposed valve is pre-set to a safe maximum shower temperature. During use, the action of the stop
button may be overridden by depressing it as the temperature control is rotated. Should it be necessary to reset
the maximum temperature position, please observe the following procedures.
1. Ensure that the hot water system is at normal maximum temperature.
2. Turn the temperature control lever to the full cold position (lever fully downwards).
3. Remove the temperature control fixing screw and pull the knob clear.
4. Remove the temperature control lever screws and pull the lever clear.
5. With the cam tooth engaged in the shaft sleeve keyway, turn the sleeve in the appropriate direction to
increase or decrease the maximum temperature. (Each increment equates to approximately 1ºC).
Colt installation guide:Dolphin install Guide 14/1/11 11:18 Page 20