Control Start-Up Procedures
3
The following outline includes a brief description of the functions of the buttons found on your control valve. A more
detailed outline is included within this service manual.
The
“SET CLOCK”
button allows you to set the time of day, cancel out of the pro-
gramming mode and saves changes when you are in the programming mode.
The
“NEXT”
button allows you to toggle between capacity & time and moves you
to the next display in the programming mode.
The
“ARROW”
buttons change the variable being displayed in the
programming mode.
The
“REGEN”
button, when pressed once, will initiate a regeneration at the regen-
eration time input into the valve (usually at 2:00 am). When the
“REGEN”
button
is held for more than three seconds, an immediate regeneration will be initiated.
The
“REGEN”
button also backs you up one step in the programming mode.
The
“SET TIME”
programming mode is entered by sim-
ply pressing the
“SET CLOCK”
button.
Adjust the hours by pressing the
or
keys. Use care
when verifying AM or PM. AM and PM will toggle after
12 AM. Once the hour is correctly set press the
“NEXT”
button to program the minutes.
Adjust the minutes by pressing the
or
keys. Once
the minutes are correctly set, press the
“NEXT”
button
to return to normal operation.