29
Timer does not display
time of day
Timer does not display
correct time of day
No softening/filtering
display when water
is flowing
Control valve regenerates at
wrong time of day
5. ERROR followed by code
number
Error Code 1001
- Unable to recognize start
of regeneration
Error Code 1002
- Unexpected stall
Error Code 1003
- Motor ran to long, timed
out trying to reach next
cycle
position
Error Code 1004
- Motor ran to long, timed
out trying to reach home
position
If other Error Codes
display contact the
factory.
a. Transformer unplugged
b. No electric power at outlet
c. Defective transformer
d. Defective PC board
a. Switched outlet
b. Power outage
c. Defective PC board
a. Bypass valve in bypass position
b. Meter connection disconnected
c. Restricted/stalled meter turbine
d. Defective meter
e. Defective PC board
a. Power outages
b. Time of day not set correctly
c. Time of regeneration incorrect
d. Control valve set at “on 0” (immedi-
ate regeneration)
e. Control valve set at on 0
a. Control valve has just been
serviced
b. Foreign matter is lodged in
control valve
c. High drive forces on piston
d. Control valve piston not in
home position
e. Motor not inserted fully to engage
pinion, motor wires broken or
disconnected, motor failure
f. Drive gear label dirty or damaged,
missing or broken gear
g. Drive bracket incorrectly aligned to
back plate
h. PC board is damaged or defective
i. PC board incorrectly aligned to drive
bracket
a. Connect power
b. Repair outlet or use working outlet
c. Replace transformer
d. Replace PC board
a. Use uninterrupted outlet
b. Reset time of day
c. Replace PC board
a. Put bypass valve in service position
b. Connect meter to PC board
c. Remove meter and check for rotation
or foreign material
d. Replace meter
e. Replace PC board
a. Reset control valve to correct time of
day
b. Reset to correct time of day
c. Reset regeneration time
d. Check control valve set-up proce-
dure regeneration time option
e. Check control valve set-up proce-
dure regeneration time option
a. Press NEXT and REGEN for 3 sec-
onds or unplug power source jack
control valve control valve
b. Check piston and spacer stack
assembly for foreign matter
c. Replace piston(s) and spacer stack
assembly
d. Press NEXT and REGEN for 3 sec-
onds or unplug power source jack
(black wire) and plug back in to reset
control valve
e. Check motor and wiring. Replace
motor if necessary
f. Replace or clean drive gear
g. Reseat drive bracket properly
h. Replace PC board
i. Ensure PC board is correctly
snapped on to drive bracket
Trouble Shooting Procedures