background image

  ►  Un-crate carefully and position HRSM on  

  level ground.
  ►  Save crate and packing materials until  

  evaluation and testing are complete.
  ►  Read manual carefully and understand all  

 instructions.
  ►  Do not connect power until after thorough  

  inspection and filling the sump with liquid.
  ►  After filling the unit with some liquid, inspect  

  for leaks.
  ►  Never operate without liquid in tank.
  ►  Be sure guards are securely in place and  

  warnings are clearly visible.
  ►  Check power supply for correct voltage.

4

G

ettinG

 s

tarteD

U

npacking

 c

hecklist

 

DO NOT OPERATE UNIT IF 

DAMAGED DURING SHIPPING, 

HANDLING OR USE. DAMAGE MAY RESULT IN BREAKAGE 

AND CAUSE INJURY OR PROPERTY DAMAGE.

WARNING

EXTENSION CORD SPECIFICATIONS*

FOR SINGLE FAN USE ONLY • (AWG - American Wire Gauge)

 

Voltage 

25 to 50 ft. 

50 to 100 ft.

      115/230 

16 AWG 

14 AWG

Fig. 12

e

lectrical

 

GROUND FAULT RECEPTACLES 

ARE RECOMMENDED AND MAY 

BE REQUIRED BY LOCAL AND/OR NATIONAL CODE.  

WARNING

USE OF AN EXTENSION CORD IS 

NOT RECOMMENDED.

IF NECESSARY, REFER TO FIG. 12.

NOTICE

*Grounded and suitable for outdoor use.

U

nit

 p

reparation

 

EN

SURE THE BLADE ASSEMBLY 

IS FREE & CLEAR FOR 

START-UP (HIGH-SPEED ROTATION). 

WARNING

Adjustment Pin

The ORSM is equipped with a four position pivoting 

fogging head with 15º intervals up to 45º (see 

Fig. 1

)

Propelling the fog upward allows more time for the 

particles to evaporate, keeping floor areas drier.

When making an adjustment, support the weight of 

the fogging head off of the pin for easy removal.

Locate a level, stable 

area to place the 

ORSM. If there's a 

slight grade, blocking 

the wheels may be 

necessary to keep unit 

secure.

Visually check to 

make sure the fan 

blades can rotate 

freely. There should 

be approximately 1/4" 

space between the 

venturi pins and the 

blades.

  Fig. 1

Содержание XE ORSM

Страница 1: ...derstand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL NOTICE Rear Feed UL and CSA Electrical Components XE ORSM MODEL 115V 60Hz 1Ph 240V 50...

Страница 2: ...afety guidelines DANGER DANGER INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT...

Страница 3: ...h use inspect blade assembly andelectricalcomponentsforsignsofdamage deterioration weakness or leakage Repair or replace defective items before using 10 Check all fasteners at frequent intervals for p...

Страница 4: ...0 ft 115 230 16 AWG 14 AWG Fig 12 Electrical GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIONAL CODE WARNING USE OF AN EXTENSION CORD IS NOT RECOMMENDED IF NECESSARY...

Страница 5: ...puts for short periods of time At the base of the plumbing is an in line strainer with a removable cap Occasionally check inside and flush any sediment from the screen The Hose Connection is used to s...

Страница 6: ...he internal valve to make adjustments and repeat process as needed see below Math example 1 minute captures 4 2 ozs x 60 128 2 GPH The valve KEY is needed to make changes You will need the KEY located...

Страница 7: ...d poor inconsistent fogging output D Consistency of fogging output greatly depends on the consistency of the cleaning procedures See Page 10 Check strainer plumbing and inside of tank for dried sedime...

Страница 8: ...betweenthemotorshaftandthestainlesssteelfaceplate Centeredintheslotareaand aimed slightly downward free from any rotational contact B Liquid not traveling through the fan blades This can be diagnosed...

Страница 9: ...ST 8 58 5 16 flat washer SST 12 114 Drain fitting nut 1 115 Drain gasket 1 116 5 16 18 finish nut SST 4 117 1 4 20 x 5 8 HH bolt SST 4 308 XE blade tip setscrew SST 3 349 5 16 brass rod 1 391 Top pivo...

Страница 10: ...Side of top pivot plate Rear of Housing To feed pump 14 16 52 600 L 117 54 20 49 58 56 32 58 57 56 57 116 349 403 391 392 56 394 395 32 479 20 600 R Motor s Junction Box 576 7 523 522 35 From Switch B...

Страница 11: ...61 84 45 71 72 65 65 295 295 W 14 65 65 84 45 198 67 65 Tank s Wall Inside Tank ORSM Tank Exploded View 232 207 86 423 423 75 171 173 143 3 8 tube fitting provided for optional connection to metering...

Страница 12: ...2 86 6 32 x 1 2 oval slotted screw 6 93 Hose connector gasket 1 94 Hose connector 1 96 Gasket 2 97 Float valve 1 98 Stem 1 99 Float 1 111 Axle SST 1 126 1 4 lockwasher SST 2 143 1 4 NPT M X 3 8 tube...

Страница 13: ...t once a year or whenever a film of calcium or mineral deposits is visible While cleaning inspect for irregularities or hairline cracks and replace as necessary 5 Storage Protect your mobile Aquafog f...

Страница 14: ...ck of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURI...

Отзывы: