![Aquafilter Clear Choice Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/aquafilter/clear-choice/clear-choice_installation-manual_2959802003.webp)
1. Safety preconditions
WARNING! The system should not be used with biologically contaminated water or water of unknown origin.
The Product may be installed only by trained service professionals. Only original replacement parts, filter cartridges and accessories
made by manufacturer may be used.
Compliance with the following instructions ensures:
- problem-free product operation,
- manufacturer's warranty.
Failure to comply with the following instructions will result in loss of warranty.
EN
1) Read carefully this Instruction Manual before begining system installation.
2) Check if all elements needed for the installation are included with the system. (refer to point 3 “Included in the Box”).
3) Please note that after installing the system, as well as after each filter cartridge and UF and RO membrane replacements, and in the case of long
inactivity of the system, system flushing procedure must be conducted before resuming system usage.
4) Prior pulling out of the tubing make sure to pull out the safety clip which protects the fastening device, next make sure to symmetrically apply the
pressure upon the flange.
5) During disconnecting and connecting of tubing be sure not to break it (correctly installed tubing should be inserted 1.5 cm inside of quick
connector).
6) After connection tubing with quick connector insert safety clip to secure the connection.
7) For sealing plastic components use only Teflon tape!
8) During the process of installation of cartridges consider the direction of water flow (the correct direction of water flow is indicated by the arrow
located upon the sticker of each and every line filter cartridges).
9) In the case of determination of any lack of tightness within the system, immediately disconnect the system from the water source.
10) In all cases of product returns, the system must be returned in its original packaging – otherwise the return will not be accepted.
11) The manufacturer does not encumber any responsibility for any losses and/or damages which stem from the fact of the exploitation of the system
for the execution of any other goals than for the needs of filtering of drinkable water.
12) The manufacturer does not encumber any responsibilities for any errors/mistakes in print.
13) The manufacturer reserves the right for the implementation of any changes or supplementation of any technical information which were had been
made available in the past, without the need for the communication of any prior notice.
®
Use only genuine
Aquafilter
filter cartridges. In case of using other brands products, the manufacturer is responsible for ineffective
performance of the system.
EXCITO-WAVE and EXCITO-OSSMO system dimensions (height x width x depth).............................................................400 mm x 345 mm x 90 mm
Tank dimensions (height x diameter)..................................................................................................................................................380 mm x 280 mm
Tank type.....................................................................................................................................................................................................PRO3200P
Tank capacity*...................................................................................................................................................................................................12 liters
O
O
Inlet water temperature........................................................................................................................................................................from 2 C to 45 C
Maximum inlet water pressure...............................................................................................................................................................3,5 bar** - 4 bar
Nominal efficiency (EXCITO-OSSMO).......................................................................................265 l / per day (with regards to membance TFC-70-TW
Nominal efficiency (EXCITO-WAVE)................................................................................................................................................................1.9 l/min
Water connector......................................................................................................................................................................................................1/2”
Inlet tubing...............................................................................................................................................................................................................1/4”
2. Technical Specifications - general information
2
Reverse Osmosis is a separation process that uses pressure to force
water through a semi-permeable membrane while retaining other
substances on the other side – it's a reverse process of what naturally
takes place in all living cells.
The membrane stops 96-99% of organic
and non-organic contaminants, bacteria and viruses.
Semi-
permeable membrane consists of many layers winded up on
perforated core. Contaminated water enters the membrane element
with pressure, forcing water molecules to pass through the microscopic
membrane pores, while flushing out contaminants to a drain.
The capillary membrane (UF) is constructed of polypropylene fibres
(capillaries). Within the walls of capillaries there are carved channels,
the diameter of which decreases in the direction from the outside in the
direction of the interior of the fibre. Larger contamination particles are
stopped upon the external surface of the capillary (filtration surface),
whereas the smaller particles are transported into the channels until
they encounter smaller pores (depth type of filtration).
Cross-section of TFC membrane elements
3. Reverse osmosis filtration technology
4. Ultra-filtration technology of water filtration - a capillary membrane (UF)
WATER INLET
PERMEABLE LAYER
SEAL/GASKET
PERFORATED CORE
PURIFIED
WATER OUTLET
EXTERNAL PROTECTIVE
LAYER
I STAGE
II STAGE
Surface type of filtration
Depth type of filtration
Particle diameter amounting to 0,02 µm
Internal capillary wall
clean, purified water
Capillary type of water filtration methods
(the sample flow through a single capillary).
* nominal capacity
** refers to the following listed systems EXCITO-WAVE
REJECTION
Содержание Clear Choice
Страница 1: ...Made in EU www aquafilter com Installation Manual Instrukcja monta u...
Страница 17: ...10 O 2 C 1 2 SEWBV1414 SEWBV1414 TAS0004 3 4 SEWBV1414 FT06 5 SEWBV1414 6 16...
Страница 18: ...11 O 2 C 1 2 SEWBV1414 TAS0004 FT07 SEWBV1414 4 3 5 6 SEWBV1414 FT07 SEWBV1414 FT02 8 7 17...
Страница 19: ...12 EXCITO WAVE EXCITO OSSMO IN OUT SEWBV1414 IN 4 OUT 7 13 EXCITO OSSMO 1 2 5 18...
Страница 20: ...SC500B14 3 SC500B14 4 5 14 EXCITO OSSMO 1 5 1 5 19...
Страница 23: ...90 1 2 1 2 90 EXCITO WAVE 19 EXCITO WAVE EXCITO OSSMO 20 EXCITO OSSMO 16 22...
Страница 24: ...1 2 90 90 16 1 1 5 2 23...