Aquafilter Clear Choice Скачать руководство пользователя страница 3

1. Safety preconditions

WARNING! The system should not be used with biologically contaminated water or water of unknown origin.
The Product may be installed only by trained service professionals. Only original replacement parts, filter cartridges and accessories 
made by manufacturer may be used.

Compliance with the following instructions ensures:
 - problem-free product operation,
 - manufacturer's warranty.
Failure to comply with the following instructions will result in loss of warranty.

EN

1)  Read carefully this Instruction Manual before begining system installation.
2)  Check if all elements needed for the installation are included with the system. (refer to point 3 “Included in the Box”).
3)  Please note that after installing the system, as well as after each filter cartridge and UF and RO membrane replacements, and in the case of long 

inactivity of the system, system flushing procedure must be conducted before resuming system usage.

4)  Prior pulling out of the tubing make sure to pull out the safety clip which protects the fastening device, next make sure to symmetrically apply the 

pressure upon the flange.

5)  During  disconnecting  and  connecting  of  tubing  be  sure  not  to  break  it  (correctly  installed  tubing  should  be  inserted  1.5  cm  inside  of  quick 

connector).

6)  After connection tubing with quick connector insert safety clip to secure the connection.
7) For sealing plastic components use only Teflon tape!
8)  During the process of installation of cartridges consider the direction of water flow (the correct direction of water flow is indicated by the arrow 

located upon the sticker of each and every line filter cartridges).

9)  In the case of determination of any lack of tightness within the system, immediately disconnect the system from the water source.
10) In all cases of product returns, the system must be returned in its original packaging – otherwise the return will not be accepted.
11) The manufacturer does not encumber any responsibility for any losses and/or damages which stem from the fact of the exploitation of the system 

for the execution of any other goals than for the needs of filtering of drinkable water.

12) The manufacturer does not encumber any responsibilities for any errors/mistakes in print.
13) The manufacturer reserves the right for the implementation of any changes or supplementation of any technical information which were had been 

made available in the past, without the need for the communication of any prior notice.

®

Use only genuine 

Aquafilter  

filter cartridges. In case of using other brands products, the manufacturer is responsible for ineffective

performance of the system.

EXCITO-WAVE and EXCITO-OSSMO system dimensions (height x width x depth).............................................................400 mm x 345 mm x 90 mm 
Tank dimensions (height x diameter)..................................................................................................................................................380 mm x 280 mm
Tank type.....................................................................................................................................................................................................PRO3200P
Tank capacity*...................................................................................................................................................................................................12 liters

O

O

Inlet water temperature........................................................................................................................................................................from 2 C to 45 C
Maximum inlet water pressure...............................................................................................................................................................3,5 bar** - 4 bar
Nominal efficiency (EXCITO-OSSMO).......................................................................................265 l / per day (with regards to membance TFC-70-TW
Nominal efficiency (EXCITO-WAVE)................................................................................................................................................................1.9 l/min
Water connector......................................................................................................................................................................................................1/2”
Inlet tubing...............................................................................................................................................................................................................1/4”

2. Technical Specifications - general information

2

Reverse Osmosis is a separation process that uses pressure to force 
water  through  a  semi-permeable  membrane  while  retaining  other 
substances on the other side – it's a reverse process of what naturally 
takes place in all living cells. 

The membrane stops 96-99% of organic 

and  non-organic  contaminants,  bacteria  and  viruses. 

Semi-

permeable  membrane  consists  of  many  layers  winded  up  on 
perforated core. Contaminated water enters the membrane element 
with pressure, forcing water molecules to pass through the microscopic 
membrane pores, while flushing out contaminants to a drain.

The capillary membrane (UF) is constructed of polypropylene fibres 
(capillaries). Within the walls of capillaries there are carved channels, 
the diameter of which decreases in the direction from the outside in the 
direction of the interior of the fibre. Larger contamination particles are 
stopped upon the external surface of the capillary (filtration surface), 
whereas the smaller particles are transported into the channels until 
they encounter smaller pores (depth type of filtration).

Cross-section of TFC membrane elements

3. Reverse osmosis filtration technology

4. Ultra-filtration technology of water filtration - a capillary membrane (UF)

WATER INLET

PERMEABLE LAYER

SEAL/GASKET

PERFORATED CORE

PURIFIED 
WATER OUTLET

EXTERNAL PROTECTIVE 
LAYER

I STAGE

II STAGE

Surface type of filtration

Depth type of filtration

Particle diameter amounting to 0,02 µm

Internal capillary wall

clean, purified water

Capillary type of water filtration methods

(the sample flow through a single capillary).

* nominal capacity
** refers to the following listed systems EXCITO-WAVE

REJECTION

Содержание Clear Choice

Страница 1: ...Made in EU www aquafilter com Installation Manual Instrukcja monta u...

Страница 2: ...osmotic membrane within the system of EXCITO OSSMO 1 13 2 13 3 13 4 13 5 RO Reverse Osmosis 14 6 14 7 JG John Guest i QC Quick connector 14 8 EXCITO WAVE 15 9 EXCITO OSSMO 15 10 16 11 17 12 EXCITO WA...

Страница 3: ...plementation of any changes or supplementation of any technical information which were had been made available in the past without the need for the communication of any prior notice Use only genuine A...

Страница 4: ...in an even and symmetrical manner fig 2 3 Pull the tubing out fig 3 Connecting the tubing 1 Press the tubing into the quick connector the correctly assembled tubing is cartridgeed 1 5 cm deep into the...

Страница 5: ...0 3 3 bar 50 psi Pressure regulating device PLV 0104 50 PLV 0104 50 3 3 bar 50 psi Connection of installation tubings A Connection to the water supply B Connecting to the faucet 9 The sample connectin...

Страница 6: ...gasket is to be found between the valve and the tubing make sure not to lose it Close the shutt off valve located upon the cold water supply pipe 1 2 Make sure to screw the connecting section onto the...

Страница 7: ...pe 1 2 Upon the thread of the ball valve SEWBV1414 apply a few layers ofTeflon tape Assemble the FT07 connecting section upon the cold water distribution pipe ensuring the position which will facilita...

Страница 8: ...e the upper cover of the system and screw it on 7 13 Installation of drainage EXCITO OSSMO WARNING Remember to take off the quick connector protection safety clip prior the process of taking out of th...

Страница 9: ...the installing of the tubing make sure to protect the quick connector with the application of the safety clip 14 Connecting of the tank EXCITO OSSMO Attach and assemble a ball valve upon the tank Con...

Страница 10: ...FXFCH17 C faucet 16 Washing of systems 1 2 3 4 5 6 7 8 9 10 11 Fig 1 The assembly of the faucet upon the kitchen table top Following the finished phase of installation the washing process is to be exe...

Страница 11: ...media which reduces the concentration of iron ions heavy metals as well as calcium and magnesium ions In line carbon and mineralising cartridge Applied in the process of osmosis filtration Improves w...

Страница 12: ...make sure to apply white cosmetic wax onto the o ring WARNING Make sure that the cartridge has been correctly installed Replace the remaining cartridges as well as the capillary membrane which is fou...

Страница 13: ...t panel WARNING During the process of the replacement of filters apply due care not to damage the tubings WARNING Following each and every replacement of cartridges and the membrane execute the washin...

Страница 14: ...8 9 10 11 12 13 Aqua Market Aquafilter EXCITO WAVE EXCITO OSSMO x x 400 mm x 345 mm x 90 mm 380 mm x 280 mm PRO3200P 12 O O 2 C 45 C 3 5 4 EXCITO OSSMO 265 TFC 70 TW EXCITO WAVE 1 9 1 2 1 4 2 96 99 TF...

Страница 15: ...lids 3 ppm 5 RO Reverse Osmosis 6 EXCITO WAVE EXCITO OSSMO PRO3200P 7 JG John Guest i QC Quick connector 1 1 2 2 3 3 1 1 5 4 2 5 1 2 3 4 5 PLV 0104 50 3 3 50 psi FXFCH17 C KTPE14W TAS0004 1 2 x 1 2 x...

Страница 16: ...8 EXCITO WAVE A B 1 2 SEWBV1414 PLV 0104 50 3 3 50 psi 9 EXCITO OSSMO A C B 1 2 SEWBV1414 PLV 0104 50 3 3 50 psi 15...

Страница 17: ...10 O 2 C 1 2 SEWBV1414 SEWBV1414 TAS0004 3 4 SEWBV1414 FT06 5 SEWBV1414 6 16...

Страница 18: ...11 O 2 C 1 2 SEWBV1414 TAS0004 FT07 SEWBV1414 4 3 5 6 SEWBV1414 FT07 SEWBV1414 FT02 8 7 17...

Страница 19: ...12 EXCITO WAVE EXCITO OSSMO IN OUT SEWBV1414 IN 4 OUT 7 13 EXCITO OSSMO 1 2 5 18...

Страница 20: ...SC500B14 3 SC500B14 4 5 14 EXCITO OSSMO 1 5 1 5 19...

Страница 21: ...4 5 6 7 EXCITO WAVE EXCITO OSSMO 6 OUT 11 10 9 8 15 FXFCH17 C 16 1 2 3 4 5 6 7 8 9 10 11 1 1 2 5 EXCITO WAVE 1 2 60 3 EXCITO OSSMO 1 2 35 40 45 50 10 15 20 25 30 5 55 60 min 35 40 45 50 10 15 20 25 3...

Страница 22: ...EXCITO WAVE EXCITO OSSMO EXCITO WAVE EXCITO WAVE EXCITO OSSMO EXCITO WAVE EXCITO OSSMO EXCITO OSSMO AISTRO 2 TW TLCHF TW TFC 70F TW FCCBL S TW FCCM TW 3 6 3 6 3 6 3 6 6 12 36 16 5 50 50 UF 0 02 0 0001...

Страница 23: ...90 1 2 1 2 90 EXCITO WAVE 19 EXCITO WAVE EXCITO OSSMO 20 EXCITO OSSMO 16 22...

Страница 24: ...1 2 90 90 16 1 1 5 2 23...

Страница 25: ...ch bez dokonania wcze niejszej zapowiedzi Nale y u ywa tylko i wy cznie oryginalnych wk ad w i membran filtracyjnych marki Aqua Market lub Aquafilter W przypadku stosowania element w innej marki produ...

Страница 26: ...ia w yk w do szybkoz czek typu JG John Guest i QC Quick connector Od czenie w yka 1 Zdj klips zabezpieczaj cy z szybkoz czki rys 1 2 Docisn symetrycznie ko nierz szybkoz czki rys 2 3 Wyci gn w yk rys...

Страница 27: ...k w instalacyjnych A Pod czenie do zasilania wody B Pod czenie do wylewki 9 Przyk adowy schemat po czenia EXCITO OSSMO A C B przy cze 1 2 zaw r odcinaj cy SEWBV1414 Zimna woda Regulator ci nienia PLV...

Страница 28: ...od zaworu przy cza elastyczny w UWAGA Pomi dzy zaworem a w ykiem znajduje si gumowa uszczelka nie zgub jej Zamkn zaw r odcinaj cy na rurze doprowadzaj cej zimn wod 1 2 Nakr ci przy cze na zaw r w poz...

Страница 29: ...ci zaw r doprowadzaj cy wod 1 2 Na gwint zaworu kulowego SEWBV1414 nawin kilka warstw ta my teflonowej Nakr ci przy cze FT07 na rur doprowadzaj c zimn wod w pozycji kt ra pozwoli na atwe wkr cenie zaw...

Страница 30: ...ezpieczy klipsem Za o y g rn obudow systemu i skr ci 7 13 Instalacja odp ywu system EXCITO OSSMO Uwaga Pami taj o tym aby przed wypi ciem w yka lub elementu za lepiaj cego najpierw nale y zdj klips za...

Страница 31: ...bezpieczy po czenie klipsem 14 Pod czenie zbiornika system EXCITO OSSMO Do zbiornika dokr ci zaw r kulowy Do zaworu pod czy w yk Prawid owo zamontowany w yk zag bi si 1 5 cm w szybkoz czce UWAGA Po za...

Страница 32: ...wylewki FXFCH17 C 16 P ukanie system w 1 2 3 4 5 6 7 8 9 10 11 Rys 1 Mocowanie wylewki na blacie kuchennym Po zako czonym etapie instalacji nale y przeprowadzi proces p ukania W tym celu nale y 1 Odkr...

Страница 33: ...awiera specjalne z o e kt re redukuje st enie jon w elaza metali ci ki a tak e jon w wapnia i magnezu Liniowy wk ad w glowo mineralizuj cy Stosowany po procesie filtracji osmotycznej Poprawia smak i z...

Страница 34: ...wskaz wek zegara UWAGA Przed instalacj wk adu nale y najpierw posmarowa oring wazelin kosmetyczn bia UWAGA Upewnij si e wk ad jest poprawnie zainstalowany W analogiczny spos b nalezy wymie pozosta e w...

Страница 35: ...a nast pnie delikatnie poci gn w d Za o y przedni panel UWAGA Podczas wymiany wk ad w nale y zachowa szczeg ln ostro no aby nie za ama w yk w UWAGA Po ka dej wymianie wk ad w oraz membrany nale y prze...

Страница 36: ...bereitgestellten Informationen und Daten vorzunehmen bernimmt keinerlei The producer does not hold any responsibility for printing errors We reserve the right to introduce change or amendments of the...

Отзывы: