background image

- 4 - 

be2adn.DOC, Seite 4 von 4, Aug. 11 

1. Safety Instructions 

1.1. General 

information 

This manual contains basic information that are 
important for assembly, operation, and mainte-
nance. This should be read before mounting by 
the assembly operator and the responsible opera-
tor and/or qualified personnel. This instruction 
must be disposable the at unit at any time.  

Pay attention to this safety instruction as well as 
to the special instructions within the other chap-
ters. In addition local laws and safety instruction 
must be minded. 

1.2.  Indication of information 

 

If safety information are important for 
life or health for persons they are marked 
with the relevant hazard symbol accord-
ing DIN 4844-W9. 

 

Safety information marked with this sym-
bol can cause danger for the machine and 
its function if not respected. 

 

This hints can ease the work with the ma-
chine and its maintenance.  

At the machine directly marked information as 
rotation arrow, fluid connections and setting 
points should be noticed. These marks should be 
readable at any time.  

1.3.  Qualification of the person-

nel  

The staff for operation, maintaining, inspection 
and assembly must be qualified for these work. 
Responsibility and controlling of the personnel 
should be directed by the operator.  

1.4.  Dangers if safety informa-

tion are not minded  

If safety information are not minded persons, en-
vironment, and the machine can be endangered. 
Failure of observe lead to loss of the warranty.  

Failure of observe can coarse: 

-  Failure of important functions of the ma-

chine. 

-  Failure of stipulated methods for mainte-

nance.  

-  Endanger of persons with electric, chemi-

cal or mechanical impacts.  

1.5. Safe 

working 

Working with the machine is only allowed if all 
safety information of this manual, national laws 
and rules for preventing accidents and internal 
working, operating and safety rules of the opera-
tor must be minded.  

1.6.  Safety information for the 

operator  

Contact protection for rotating or moving parts 
should not be removed while operation.  

Risks of electrical energy must be averted. Please 
pay attention to the local laws and information, 
too.  

1.7.  Safety information for main-

taining and assembling per-
sonnel 

The operator must take care that all works for as-
sembling, inspecting and maintaining are made 
by authorized and qualified personnel. These per-
sons must be informed about the machine and the 
works by reading the manual or otherwise.  

Working at the machine is only permitted if unit 
is out of operation. The described procedure of 
putting out of operation must be redeemed. Im-
mediately after the work safety and protection fa-
cilities must be mounted and put into function.  

Before starting again all issues treated in the 
chapter “putting into operation” must be minded.  

1.8. Arbitrary 

reconstruction 

and spare parts production  

Reconstruction or modifying the unit are only 
proper if the manufacture agrees. Original spare 
parts and authorized accessories by the manufac-
ture are made for the safety. The use of other 
parts can destroy the warranty demands. 

Содержание ADN1000-a

Страница 1: ...water desalination and purification Syst mes pour aquacultur aquariums eau de mer labaratoires et tra tements d eau AquaCare GmbH Co KG Am Wiesenbusch 11 D 45966 Gladbeck Tel 49 2043 375758 0 Fax 49 2...

Страница 2: ...ectors 7 6 3 Electrical connection 7 6 4 Filling up with sulphur granules 8 7 Start up the unit 8 7 1 Filling up with water 8 7 2 Adjusting the water flows 9 7 3 Adjusting the times for flushing and i...

Страница 3: ...3 be2adn DOC Seite 3 von 3 Aug 11 15 Appendix motor 17...

Страница 4: ...observe lead to loss of the warranty Failure of observe can coarse Failure of important functions of the ma chine Failure of stipulated methods for mainte nance Endanger of persons with electric chemi...

Страница 5: ...10 out of the horizontal position Before transporting the unit it must be totally empty this does not apply to the filter bed gran ules 3 Designated use AquaCare de nitrifying filter are only made for...

Страница 6: ...ball valve 3 flow meter for filtering mode 4 ball valve for filtering mode 5 ball valve for flushing mode 6 automatic ball valve only model a 7 ball valve for feed water 8 check valve for feed water 9...

Страница 7: ...eration location is over 1000 me ter over the sea level the motor must be larger dimensioned to protect it against overheating 6 2 Water connectors To operate the unit you must install water and elect...

Страница 8: ...wise the pump soaks granules into the inlet and get damaged Tighten the plastic bolds with maximum 3 Nm Higher forces destroy screws and the threads 7 Start up the unit Before start up the unit check...

Страница 9: ...me and the timer 10c of the interval Take care that the time for interval is never below 1 minute Otherwise the automatically driven ball valve can collapse Adjust the times in the start up phase to 1...

Страница 10: ...he aquarium If the nitrate concentration in the aquarium is be low 5 mg l the efficiency of the ADN filter should be lowered A nitrate concentration about 0 mg l is not good for the animals and the AD...

Страница 11: ...d or too less flushing is realized the filter bed can block A Flush the system intensively by opening the flushing valve 5 resp by pushing the pushbutton 10f The produced particles and too much bacte...

Страница 12: ...Ventilate the room and leave it at once Hydrogen sulfide is formed if any nitrate is in the circulation water of the ADN Increase the water inlet to the ADN to make sure that the outlet wa ter contain...

Страница 13: ...e 4 40 C Umgebungstemperatur ambient temperature 4 45 C Hauptpumpe main pump Hersteller manufacturer Typ type Nr No minimale F rdermenge minimum flow Magnetisch gekoppelte Kreiselpumpe magnetic couple...

Страница 14: ...2 L3 dito L1 N dito L2 N dito L3 N Strom current L1 Strom current L2 Strom current L3 Strom N Testbedingungen test conditions 390 V 390 V 391 V 221 V 228 V 225 V 24 0 A 24 3 A 23 5 A 0 52 A Normleistu...

Страница 15: ...15 be2adn DOC Seite 15 von 15 Aug 11 13 Appendix switch board...

Страница 16: ...16 be2adn DOC Seite 16 von 16 Aug 11 14 Appendix pump...

Страница 17: ...17 be2adn DOC Seite 17 von 17 Aug 11 15 Appendix motor...

Отзывы: