Main Components 

Tri-

s

ensor Assembly

Pool Pilot  

Cell

Flow In 

Flow Out 

  

Soft Touch 

Control Box 

Patented Automatic Flow Bypass Manifold Assembly 

CONTROL BOX 

converts incoming  

AC power to a Low Voltage DC current, 
which energizes the Cell(s). Set the 

Control Box

 on a vertical surface away 

from excessive exposure to heat and 
moisture. Use the template to mark and 
drill the (4) mounting holes and insert 
the screws, leaving a ¼” gap. Hang the 
control box on the screws and level.   
Remove the cover by following the steps 
on page 10 to access the mounting 

ELECTROLYTIC 

POOL PILOT 

CELL

 receives Low Voltage DC 

current from the Power Circuit Board, 
which initiates the electrolytic process. 
This process converts ordinary table 
salt (Sodium Chloride) to 100% Pure 
Sodium Hypochlorite (Chlorine Bleach) 
or Bromine (with the addition of 
Sodium  Bromide), which in turn 
purifies your pool or spa.   
See page 8 for salt requirements. 

TRI-SENSOR ASSEMBLY

 

ensures that adequate  

flow

, 15gpm (3.4 m³/hr) minimum; 

salt

25

00 – 

4

500 ppm

(2,5 – 3,5 gm/l) ideal range; and  

water temperatures

, above  

55

F (13 

C) are satisfactory to  

prevent abusive conditions for the  
cell to operate.  See page 10 for  
instructions to remove and inspect  
the 

T

ri-sensor assembly.

holes to tighten the screws.   

RATINGS: 

Input Power: 115 VAC (3.0 AC amps) 

Cl

Output Rating: 

PPC4

230 VAC (1.5 AC amps) 

@ Cell Power 3  

PPC3

50/60 Hz 

(8 amps DC) 

PPC1

2.62 lbs/day (1.19 kg/day)

1.92

 lbs/day (0.

87

 kg/day)

1.56 lbs/day (0.71 kg/day) 
1.28 lbs/day (0.58 kg/day) 

Output Power:  Cell Power 1 (5.0* DC amps) 

Agency Approvals: NSF, ETL

 

us, ETL

 

c, CE  

Cell Power 2 (6.5* DC amps) 
Cell Power 3 (8.0* DC amps) 

*Indicates nominal amperage output.  The dual axis controller will slightly vary the amps to optimize the power to the cell.

The  cell  and 

T

ri-sensor  are  located  in  a  Patented  Automatic  Flow  Bypass  Manifold  Assembly.    12’  (3.6  m)  of 

Cell  and

Tri-

s

ensor cords

 are provided with the unit.  Ensure that the manifold is located within that distance from the control box

with enough slack to allow for removal for service or maintenance.  

CAUTION:

 It is suggested to locate the cell downstream of all other equipment and on the pool return line only to avoid 

over-saturation conditions of your spa.  For applications other than as recommended, contact the factory. 

Maximum Operating Pressure: 50 psi 
Maximum Flow Rate: 100 gpm 

PPC

5

Содержание ST-220

Страница 1: ...d Spa Purification System Pool Pilot Soft Touch by AquaCal AutoPilot Inc Owners Manual Installation and Operation For Indoor or Outdoor use IMPORTANT Read This Manual Before Installing Operating 18500...

Страница 2: ...el Number ST 220 Serial Number ____________________________ Cell Pool Pilot Cell Model Number _ Serial Number ____________________________ Factory Direct Customer Assistance 1 727 823 5642 FAX 1 877 4...

Страница 3: ...Maintain water chemistry in accordance with manufacturer s instructions 6 WARNING PERSONAL SAFETY HAZARD To reduce the risk of injury do not permit children to use this product unless they are closel...

Страница 4: ...Tri sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt...

Страница 5: ...tures above 55 F 13 C are satisfactory to prevent abusive conditions for the cell to operate See page 10 for instructions to remove and inspect the Tri sensor assembly holes to tighten the screws RATI...

Страница 6: ...ach to the 2 Banana Jacks on the bottom of the Control Box Polarity does not matter The other end of the cell cord has a three position plug that connects to the cell in any direction For the PPC1 and...

Страница 7: ...r other plumbing configurations please contact the factory for assistance Verification of Flow Switch Protection It is important to annually inspect and verify the safe and proper operation of the Tri...

Страница 8: ...self cleaning cycle can control change the setting to SHORT For optimum water chemistry balance according to the Saturation Index see page 9 you can change the REVERSING cycle to LONG Pressing the set...

Страница 9: ...salt you use contain a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips...

Страница 10: ...vels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name and allows the chlorine residual to last longer by protecting it from the UV degra...

Страница 11: ...activate the flow switch As the water flow closes the paddle a magnet activates a micro switch to verify proper flow The Salt sensor protects against low salt levels and the temperature sensor protec...

Страница 12: ...ed with a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades Remove the Cell cord and immerse the Cell so that the blades...

Страница 13: ...ION COMPLETE 19070 Union O Ring 19070 0 Union O Ring 19070 0 Cell s PPC1 PPC3 PPC4 PPC5 1 5 Half union 312 C 2 Slip Union 312 B 2 Slip Union 312 B 1 5 Half Union 312 C 38 mm 51 mm 51 mm 38 mm Nut only...

Страница 14: ...the Cell B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when exces...

Страница 15: ...se of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pause Read 2 800 PPM 2 The second...

Отзывы: