4
Section 2a –
INSTALLATION
Main Components
Tri-
s
ensor Assembly
Pool Pilot
Cell
Flow In
Flow Out
Soft Touch
Control Box
Patented Automatic Flow Bypass Manifold Assembly
CONTROL BOX
converts incoming
AC power to a Low Voltage DC current,
which energizes the Cell(s). Set the
Control Box
on a vertical surface away
from excessive exposure to heat and
moisture. Use the template to mark and
drill the (4) mounting holes and insert
the screws, leaving a ¼” gap. Hang the
control box on the screws and level.
Remove the cover by following the steps
on page 10 to access the mounting
ELECTROLYTIC
POOL PILOT
CELL
receives Low Voltage DC
current from the Power Circuit Board,
which initiates the electrolytic process.
This process converts ordinary table
salt (Sodium Chloride) to 100% Pure
Sodium Hypochlorite (Chlorine Bleach)
or Bromine (with the addition of
Sodium Bromide), which in turn
purifies your pool or spa.
See page 8 for salt requirements.
TRI-SENSOR ASSEMBLY
ensures that adequate
flow
, 15gpm (3.4 m³/hr) minimum;
salt
,
25
00 –
4
500 ppm
(2,5 – 3,5 gm/l) ideal range; and
water temperatures
, above
55
F (13
C) are satisfactory to
prevent abusive conditions for the
cell to operate. See page 10 for
instructions to remove and inspect
the
T
ri-sensor assembly.
holes to tighten the screws.
RATINGS:
Input Power: 115 VAC (3.0 AC amps)
Cl
2
Output Rating:
PPC4
230 VAC (1.5 AC amps)
@ Cell Power 3
PPC3
50/60 Hz
(8 amps DC)
PPC1
2.62 lbs/day (1.19 kg/day)
1.92
lbs/day (0.
87
kg/day)
1.56 lbs/day (0.71 kg/day)
1.28 lbs/day (0.58 kg/day)
Output Power: Cell Power 1 (5.0* DC amps)
Agency Approvals: NSF, ETL
us, ETL
c, CE
Cell Power 2 (6.5* DC amps)
Cell Power 3 (8.0* DC amps)
*Indicates nominal amperage output. The dual axis controller will slightly vary the amps to optimize the power to the cell.
The cell and
T
ri-sensor are located in a Patented Automatic Flow Bypass Manifold Assembly. 12’ (3.6 m) of
Cell and
Tri-
s
ensor cords
are provided with the unit. Ensure that the manifold is located within that distance from the control box
with enough slack to allow for removal for service or maintenance.
CAUTION:
It is suggested to locate the cell downstream of all other equipment and on the pool return line only to avoid
over-saturation conditions of your spa. For applications other than as recommended, contact the factory.
Maximum Operating Pressure: 50 psi
Maximum Flow Rate: 100 gpm
PPC
5