Trim Kit for TURBO thermostatic valve T-12123
8
last revision: 15/10/2020
aquabrass.com
To service the cartridges
Entretien des cartouches
Maintenance
Shut off the main water supply, then remove all
the
components from (6) to (19). (See Fig.6). After-
wards, shut off the 2 check valves (1) by turning
them clockwise with a screwdriver. Unscrew the
screw (3), the large nut (4) and remove the car-
tridges (2 & 5).
To clean the cartridges (thermostat only), you
may need to soak it in a vinegar and water so-
lution to remove lime build-up. If replacement is
necessary, insert the new cartridges and screw
the large nut (4), the screw (3) back on.
DO NOT
OVERTIGHTEN.
To reinstall the components, reverse the above
steps.
1
2
4
6
7
8
13
14
15
5
9
10
11
12
17
19
18
16
3
Fig.6
Fermer l’alimentation d’eau principale et dé-
monter
toutes les composants de (6) à (19) (Voir Fig.6).
Ensuite, fermer les deux valves d’arrêt (1) en les
vissant dans le sens des aiguilles d’une montre.
Dévisser la vis (3), le manchon de valve (4) et en-
lever les cartouches (2 & 5).
Pour nettoyer les cartouches (thermostat seule-
ment), plongez les dans une solution d’eau et de
vinaigre. Si nécessaire, insérer les nouvelles car-
touches revisser les manchons des valves (2 &
5) et la vis (3).
NE PAS TROP SERRER !
Pour remonter tous les composants, inverser les
étapes ci-haut.