background image

5

System Parts

Introduction

Thank you for your purchase of the TurboTAC salt-

free limescale prevention and water filtration system.

This water treatment system has been designed and 

tested to provide you with high quality drinking water 

and limescale prevention for years to come.

System Parts

Installation Instructions

Housing

Outlet Connector

Head Assembly

1  MPT Threaded Inlet / 

Outlet Adapters (x2)

Pressure Relief Valve

Inlet / Outlet red Adapter 

Locking Pins (x2)

Sediment / Carbon Filter 

Cartridge (20 microns)

Scale Reduction 

(TAC) Cartridge

Multifunction Tool

Mounting Bracket

2

Introduction

Thank you for your purchase of Watts salt-free scale 

prevention and water filtration system.

 This Watts water treatment 

system has been designed and tested to provide you with high qual-

ity drinking water fand scale prevention for years to come. 

Installation Instructions

New systems come with the cartridges and outlet connector pre-installed.  Installer 

should verify this during installation.
1.  Please confirm that all items required are included in the kit ready for assembly 

and remove from carton. 

 

2.  Find a suitable location for the system keeping in mind access to the 

water supply and delivery to the home, restaurant or foodservice equipment.
3. The system can stand upright in the desired location without the need to affix 

to a wall with a mounting bracket. However, a mounting bracket is available as a 

separate part (Item 10)
4.  Take the two 1”MPT Threaded Adapters (Item 5) and insert them into the inlet and 

outlet of the Housing (Item 1) as shown in Diagram A.
5. Secure these adapters with the two red adapter Locking Pins (Item 6) as shown in 

Diagram A.
6.  Take the Sediment/Carbon Filter cartridge (Item 7) and place it within the One-

Flow+ Housing (Item 1) as shown in Diagram B.
7. Take the Scale reduction cartridge (Item 8) and secure it within the 

centre of the Sediment/Carbon Filter cartridge (Item 7) as shown in Diagram C.
8.  Take the Outlet Connector (Item 4) and install it as shown in Diagram D.
9.  Take the Head Assembly (Item 2) and screw this onto the  

Housing (Item 1) as shown in Diagram E.

NOTICE

10.  To tighten take the Multifunction Tool (Item 9] and tighten the Head Assembly as 

shown in Diagram E by tightening  in a clockwise direction – DO NOT OVER TI GHTEN
11.  Using plumbing tape connect water supply to the inlet of the system 

and connect to the outlet of the System as required.
12.  Turn on water supply and check for leaks.

Diagram  A

Diagram  B

Diagram  C

Diagram  D

CLOSE

Diagram  E

Diagram  F

OPEN

Diagram  G

Diagram  H

System Parts

NOTICE

IOM-WQ-.indd   2

10/15/2015   11:22:12 PM

Housing

Head Assembly

Pressure Relief Value

Outlet Connector

Threaded Inlet / Outlet 

Adapters (x2)

Inlet / Outlet Red Adapter

Looking Pins (x2)

Sediment / Carbon Filter

Cartridge (20 micorns)

Scale Reduction 

(TAC) Cartridge

Multifunction Tool

Mounting Bracket

New systems come with the cartridges and outlet connector pre-installed. Installer 

should verify this during installation. When changing cartridges reverse installation 

procedure and note items 6 & 7.

1. Please confirm that all items required are included in the kit ready for assembly and 

remove from carton.
2. Find a suitable location for the installation keeping in mind access to the incoming 

water supply and the treated supply to the home, restaurant or foodservice 

equipment.
3. The system must stand upright in the desired location and secured using the wall 

mounting bracket provided where possible.
4. Take the two threaded Adapters (Item 5) and insert them into the inlet and outlet of 

the TurboTAC Housing (Item 1) as shown in Diagram A.
5. Secure these adapters with the two red adapter Locking Pins (Item 6) as shown in 

Diagram A.
6. Take the Sediment/Carbon Filter cartridge (Item 7) and place it within the TurboTAC 

Housing (Item 1) as shown in Diagram B.
7. Take the Next TAC Scale reduction cartridge (Item 8) and secure it within the centre 

of the Sediment/Carbon Filter cartridge (Item 7) as shown in Diagram C.
8. Take the Outlet Connector (Item 4) and install it as shown in Diagram D.
9. Take the Head Assembly (Item 2) and screw this onto the Housing (Item 1) as 

shown in Diagram E.
10. To tighten take the Multifunction Tool (Item 9] and tighten the Head Assembly as 

shown in Diagram E by tightening in a clockwise direction – DO NOT OVER TIGHTEN
11. Using PTFE tape connect incoming water supply to the inlet of the TurboTAC 

system and connect to the outlet as required to service the property.
12. Turn on water supply and check for leaks. Open first cold water tap on the system 

to release any air, and run the system for 5 minutes before putting into service.

Housing

Outlet Connector

Head Assembly

1  MPT Threaded Inlet / 

Outlet Adapters (x2)

Pressure Relief Valve

Inlet / Outlet red Adapter 

Locking Pins (x2)

Sediment / Carbon Filter 

Cartridge (20 microns)

Scale Reduction 

(TAC) Cartridge

Multifunction Tool

Mounting Bracket

2

Introduction

Thank you for your purchase of Watts salt-free scale 

prevention and water filtration system.

 This Watts water treatment 

system has been designed and tested to provide you with high qual-

ity drinking water fand scale prevention for years to come. 

Installation Instructions

New systems come with the cartridges and outlet connector pre-installed.  Installer 

should verify this during installation.
1.  Please confirm that all items required are included in the kit ready for assembly 

and remove from carton. 

 

2.  Find a suitable location for the system keeping in mind access to the 

water supply and delivery to the home, restaurant or foodservice equipment.
3. The system can stand upright in the desired location without the need to affix 

to a wall with a mounting bracket. However, a mounting bracket is available as a 

separate part (Item 10)
4.  Take the two 1”MPT Threaded Adapters (Item 5) and insert them into the inlet and 

outlet of the Housing (Item 1) as shown in Diagram A.
5. Secure these adapters with the two red adapter Locking Pins (Item 6) as shown in 

Diagram A.
6.  Take the Sediment/Carbon Filter cartridge (Item 7) and place it within the One-

Flow+ Housing (Item 1) as shown in Diagram B.
7. Take the Scale reduction cartridge (Item 8) and secure it within the 

centre of the Sediment/Carbon Filter cartridge (Item 7) as shown in Diagram C.
8.  Take the Outlet Connector (Item 4) and install it as shown in Diagram D.
9.  Take the Head Assembly (Item 2) and screw this onto the  

Housing (Item 1) as shown in Diagram E.

NOTICE

10.  To tighten take the Multifunction Tool (Item 9] and tighten the Head Assembly as 

shown in Diagram E by tightening  in a clockwise direction – DO NOT OVER TI GHTEN
11.  Using plumbing tape connect water supply to the inlet of the system 

and connect to the outlet of the System as required.
12.  Turn on water supply and check for leaks.

Diagram  A

Diagram  B

Diagram  C

Diagram  D

CLOSE

Diagram  E

Diagram  F

OPEN

Diagram  G

Diagram  H

System Parts

NOTICE

IOM-WQ-.indd   2

10/15/2015   11:22:12 PM

Turbo

TAC

Compact

Housing

Head Assembly

Pressure Relief Valve

Outlet Connector

Threaded Inlet / Outlet 

Adapters (x2)

Inlet / Outlet Red Adapter

Looking Pins (x2)

Sediment / Carbon Filter

Cartridge (20 microns)

Scale Elimination 

Cartridge

Multifunction Tool

Mounting Bracket

Innovative purification solutions

www.aquablu.com

Содержание Soft Shield Elite

Страница 1: ...Manual Soft Shield Elite ...

Страница 2: ...ou and your family Failure to adhere to the information provided in this manual may lead to significant risks for the health and safety of people or damage to goods STORAGE USE AND TRANSFER OF THIS MANUAL This manual and other relevant documentation such as proof of purchase inspection and maintenance records must be kept in a suitable and safe location for future reference If a change of ownershi...

Страница 3: ... or well water that is of an unknown quality without adequate pre filtration and or disinfection before or after the system 4 Product performance is dependent upon incoming water supply quality 5 The system must be installed and maintained in accordance with the manufacturer s instructions including replacement of the filter cartridges 6 Please ensure all o rings are well lubricated and clean from...

Страница 4: ...r intervals for damaged or defective parts The system should not be used when it shows any visible damage or has damage to components or any other conditions that may affect its safe operation Have any damaged or defective parts repaired or replaced by an authorized Aquablu dealer Improper repairs can cause considerable danger Never attempt to remove or replace any parts other than those specified...

Страница 5: ... 3 The system must stand upright in the de mounting bracket provided where possible 4 Take the two threaded Adapters Item 5 the TurboTAC Housing Item 1 as shown i 5 Secure these adapters with the two red Diagram A 6 Take the Sediment Carbon Filter cartridg Housing Item 1 as shown in Diagram B 7 Take the Next TAC Scale reduction cartr of the Sediment Carbon Filter cartridge Ite 8 Take the Outlet Co...

Страница 6: ...ter Locking Pins Item 6 as shown in Diagram A 6 Take the Sediment Carbon Filter cartridge Item 7 and place it within the Softshield Housing Item 1 as shown in Diagram B 7 Take the Aquablu Scale Elimination cartridge Item 8 and secure it within the centre of the Sediment Carbon Filter cartridge Item 7 as shown in Diagram C 8 Take the Outlet Connector Item 4 and install it as shown in Diagram D 9 Ta...

Страница 7: ...m F OPEN Diagram G Diagram H er to release any air and run the system for 5 minutes before putting into service dapter x2 ol 2 12 Turn on water supply and check for leaks Diagram A Diagram B Diagram C Diagram D CLOSE Diagram E Diagram F OPEN Diagram G Diagram H Innovative purification solutions www aquablu com ...

Страница 8: ...e Scale Elimination Cartridge Item 8 from the Sediment Carbon Cartridge item 7 as shown in Diagram H 6 Remove the Sediment Carbon item 7 from the Housing by hand 7 Remove new Sediment Carbon cartridge from packaging and place carefully inside the Soft Shield Elite Housing as shown in Diagram B 8 Insert Aquablu Scale Elimination Cartridge back into the centre of the Sediment Carbon cartridge making...

Страница 9: ...m F OPEN Diagram G Diagram H er to release any air and run the system for 5 minutes before putting into service dapter x2 ol 2 12 Turn on water supply and check for leaks Diagram A Diagram B Diagram C Diagram D CLOSE Diagram E Diagram F OPEN Diagram G Diagram H Innovative purification solutions www aquablu com ...

Страница 10: ...e pH Level 6 5 to 8 5 Max Hardness 1300ppm CaCO3 Chlorine 3 ppm Iron Ferrous 0 3 mg L Manganese 0 5 mg L Copper 1 3 mg L Oil Phosphates zero Hydrogen Sulfide H2S zero Contamination treatment Sediment Particulates 20 microns with a dirt holding capacity up to 1 kg 2 2 lbs Chlorine Reduction 189 000 litres 11 34 lpm according to lab test of carbon block manufacturer Scale Prevention Up to 3 years Ce...

Страница 11: ...his User Manual has been created with great care however Aquablu Innovative purification solutions cannot be held responsible for errors in this publication or for the impact of any of these possible errors This User Manual has been written and published by Aquablu Innovative purification solutions in Voorhout To all our deliveries the general delivery conditions of the Federation of Metal and Ele...

Страница 12: ...www aquablu com member of the Stokvis Group ...

Отзывы: