Aqua J-8010 Скачать руководство пользователя страница 3

 

Important Precautions 

 

1.  In order to prevent severe damage to the unit, never power on the unit when it is outside of the 

swimming pool.   

 

2.  The power cord must be connected to an appropriate earthed socket.   

 

3.  Do not operate the unit when people are in the pool.   

 

4.  Ensure the drainage pipe for technical compartment leakage is pre-buried. 

 

5.  For optimal performance, before power on make sure that there is no air left inside the unit 

(full of the water through priming jet which is inside of the unit).   

 

6.  Do not try to lower the unit down to the level of the ground. Install them always above the 

ground according to the installation guidance. 

 

7.  Before power on, make sure the unit is connected well with the control panel, which could 

affect the unit

’s performance or cause damage.   

 

8.  The filter bags should be cleaned every time you use the unit. This will prevent that the dirty 

filter bags affect the normal operation of the unit.   

 

9.  The unit should be stored in a cool and ventilated place or protected with cover, away from 

direct sunlight, when not in use.   

 

10. The control panel should be placed indoor area. In order to avoid raining and the potential 

damage of components, never cover the control panel with wet items. 

 

11. Only authorized after sales service personnel should open the technical compartment and the 

control panel, otherwise the warranty will be invalidated.   

 

12. In order to avoid any accident, it is strongly recommended to connect the handrail with the unit 

(included in the box) for the safety of going up and down the pool. 

 

13. Do not use the unit beyond the working environment/conditions stated in this manual.   

 

 

 

Please  read  the  instruction  manual  carefully  before  use  and  keep  it  for  future 
reference. 

Содержание J-8010

Страница 1: ......

Страница 2: ...chnical Compartment Pit 6 7 Prepare Indoor Control Panel Pit 8 Connect The Control Panel To The Unit 8 Operation Guiding For Parts Of The Unit 9 Guiding For By Pass Pipes 9 Instruction Of The Control Panel 10 12 Clean The Pool Manually With Filtration System 13 14 Daily Maintenance 14 Frequent Asked Questions 14 Guarantee of services 15 ...

Страница 3: ...mance or cause damage 8 The filter bags should be cleaned every time you use the unit This will prevent that the dirty filter bags affect the normal operation of the unit 9 The unit should be stored in a cool and ventilated place or protected with cover away from direct sunlight when not in use 10 The control panel should be placed indoor area In order to avoid raining and the potential damage of ...

Страница 4: ...micals to pool switch off the valve 5 Vacuum functions This system has two vacuum functions All dirt debris can be sucked into the skimmer basket or sucked through the vacuum pipe then out 6 Massage functions Our machine has turbo boost massage jet something like Jacuzzi And air switch can be used to control the air bubble And auxiliary jet can assist the massage jet to strengthen the power of the...

Страница 5: ...ering 15m3 h Underwater Light 6W 12V LED Filter Capability 5um Filter Medium Bag Filter N W 80Kgs G W 95Kgs Available Colors White Yellow Blue Red Packing Size Main Host 1060 670 880mm Handrail 1140 810 100mm Prepare Technical Compartment Pit Beside The Pool 1 Please make sure The Gap Pool wall for supporting the filtration unit between technical compartment and filtration compartment is 25cm Fig ...

Страница 6: ...or inside of the unit please open a suitable hole yourself But please make sure the location is well connected with the drainage pipe Fig 2 4 Please take care of the wire in the electrical conduit pipe to connect the technical compartment is 4 2 5m2 If possible please make the wire inside of a protective sheath 5 Please leave the handrail 2 round holes for installation accordingly Fig 3 Handrail H...

Страница 7: ...nit and decorate the gap between compartment and the pool wall Prepare Indoor Control Panel Pit 1 The size for indoor control panel pit should be 280 180 100mm Fig 4 2 Control panel is not water proof is a must to install it indoor and never cover or wet it Fig 4 Connect The Control Panel To The Unit 1 Connect the cable to the junction box inside of the unit Fig 5 2 Connect the cable to the contro...

Страница 8: ...chlorine for 1 m3 pool water 3 Strengthen power with pneumatic switch to change the pump speed to high or low 4 Close the side water nozzle to strengthen the front nozzle power 5 Boost the water bubble by air switch 6 Change the directions of the discharge nozzle for massage or filtration Guiding For By Pass Pipes 1 Vacuum Ports There are two vacuum ports in our filtration unit Vacuum inlet locate...

Страница 9: ...g 6 Instruction Of The Control Panel Basic Operation Guiding POWER This switch cannot shut down the general power please shut down the general power if long time no uses our unit Press POWER button the unit will work and the indicator above the button will be on in red When the pump working mode is manual screen will display content same as below Fig 7 Fig 7 If no setting pump will keep manual wor...

Страница 10: ...rking mode is manual press PUMP button to Switch ON OFF pump Indicator above the button will be on off accordingly LAMP Button Press LAMP button to Switch ON OFF the lamp Indicator above the button will be on off accordingly OZONE Button Press OZONE button to Switch ON OFF the ozonator Indicator above the button will be on off accordingly UP Button Adjust the menu upward DOWN Button Adjust the men...

Страница 11: ...ode to manual or automatic MAN Manual AUT Automatic Fig 11 Time Setting for Automatic working mode When Pump is under automatic working mode Press MENU Button to get the time setting for automatic working press UP and DOWN buttons to set the time press ENTER button for confirmation The picture showing below is the working time from Saturday to Sunday 7 days Fig 12 Fig 12 Remark When pump is under ...

Страница 12: ...l Manually With Filtration System 1 Connect the hose to the vacuum cleaner head 2 Position the vacuum cleaner head at the bottom of the pool 3 Fill the hose with water by using the discharge nozzle of our filtration system 4 Position the dual plate We offer two plates for vacuum Please put white plate first if the power is not big please put the transparent plate again if the power is still not bi...

Страница 13: ...se the recipient and shake it 21 Check the levels on a white background 22 Enjoy Degaulle Pool Life REMARK IF YOU STILL CANNOT UNDERSTAND HOW TO OPERATE PLEASE ASK CALL OR EMAIL US BACK WE WILL SEND YOU PICTURE INSTRUCTION FOR DETAILS Daily Maintenance 1 Keep the filtration house tidy and clean all the time Clean the stubborn blot with rubbing alcohol or detergent Polish the scratch with silver sa...

Страница 14: ...ump or plumbing system is not vacuumed water inlet does not work or filter bag is too dirty 3 Q Why the underwater light is off A No power supply or the bulb is broken 4 Q Why the motor does not work A No power supply or connector loosen 5 Q Why the Circuit breaker trip automatically A The circuit is leaking or wrong connecting Guarantee of services ...

Страница 15: ...16 ...

Отзывы: