3.5.6 mA mode
This mode allows the user to connect the pump to an external mA signal. The current supplied to the
pump (via the input signal) determines the dosage proportional to the minimum (4mA) and maximum
values set. This mode is used when an external signal is available and there is a need to accurately
dose the chemical product according to an input current signal. The adjustable values cannot be
lower than 4 mA or higher than 20 mA.
Here are the steps to set up this feature: