background image

EVP56-100

 

Technical Specifications

 

 

Model   

Permitted 

Liquid 

Pump Specifications   

Main   

Body 

Material 

Type   

Max 

Delivery 

Rate   

Max   

Delivery 

Pressure   

By-pass  Filter    Connection   

Weight 

L/min   

MPa   

Kg   

EVP56-100 

100V

   

Diesel Oil, 

Kerosene

Light 

Oil 

FC   

Vane/ 

Self-priming   

46 

0.21    Internal   

Internal, 

100 

micron   

Rc1"   

9.1   

 

Motor Specifications 

 

Type

 

Voltage 

 

Frequency

 

Power

 

Continuous Operation

 

 

 

Hz 

 

KW(A) 

 

Single Phase Current 

 

AC100 

 

50/60 

 

0.37/0.45 

 

Possible

 

 

 

DIMENSIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY AND SERVICE 

Содержание EVP56-100

Страница 1: ... H 56 100 Electric Pump for light oil diesel oil INSTRUCTION MANUAL Contents 1 Safety precautions 1 3 Before using the device 4 Parts description 5 Place and way of use 6 Specifications drawings 7 Warranty and service ...

Страница 2: ...essary BEFORE USING THE DEVICE Read and strictly follow instructions on liquid s use Refer to information on liquid you wish to transfer Read it carefully and use the liquid properly In case of direct contact with liquid act immediately In case of liquid ingestion skin contamination etc immediately proceed with liquid s safety procedures and seek medical attention Not following the instructions ma...

Страница 3: ... matters are restricted to authorized experts Safety precaution when changing the liquid When changing the liquid you are going to transfer remember to remove the previous liquid and clean the device Not doing so may result in dangerous chemical reactions Request technical service whenever required When the device stops operating or operates in a strange manner immediately turn off the device and ...

Страница 4: ...dry state Do not exceed the supply power voltage range In case of device s malfunction If you experience device s malfunction immediately disconnect the device from the power source Contact the vendor or manufacturer Pump s permitted temperature range 5 60 Please remember that the safety measures and warnings pointed out in this manual are not exhaustive for all possible situations Although we hav...

Страница 5: ...PARTS DESCRIPTION Switch ON OFF Connection Part Delivery Rc1 Electric Power Cord AC100 1 6m Connection Part Suction Rc1 4 ...

Страница 6: ...e with low humidity and dust concentration If the pump has been switched on and is operational yet no suction occurs pour approx 240cc of transferred liquid into pump s delivery outlet before turning the pump on Avoid running the pump in a dry state as it may be damaging to its inner components 2 Start the device by using a switch on the back of the pump 5 1 Check the installation Hoses piping ...

Страница 7: ... Pressure By pass Filter Connection Weight L min MPa Kg EVP56 100 100V Diesel Oil Kerosene Light Oil FC Vane Self priming 46 0 21 Internal Internal 100 micron Rc1 9 1 Motor Specifications Type Voltage Frequency Power Continuous Operation V Hz KW A Single Phase Current AC100 50 60 0 37 0 45 Possible DIMENSIONS WARRANTY AND SERVICE 6 ...

Страница 8: ...not be free In both cases covering shipment and shipment related costs is customer s responsibility The product s breakdown has been reported within 12 months from the date of purchase but The product has been misused The product has been repaired serviced however not by AQUASYSTEM The product has not been stored or maintained properly There are no documents receipts which would prove the purchase...

Отзывы: