EVP56-100 model has been designed for kerosene and light 
oil transfer.

 

Do not use it for transferring other liquids.

 

Liquid uplift: 1.6m. 

Do not damage the electric power cord. 
Do not manipulate it, bend or pull it excessively, do not pin 
it.  Do  not  put  heavy  objects  on  the  cord.  It  may  result  in 
damaging the cord, in fire and in an electric shock. 

Do not run the device in a dry state.

 

Do not exceed the supply power voltage range.

 

In case of device

s malfunction. 

If  you  experience  device

s  malfunction,  immediately 

disconnect  the  device  from  the  power  source.  Contact  the 
vendor or manufacturer. 

Pump

s permitted temperature range: 5

~60

 

 

Please  remember,  that  the  safety  measures  and  warnings 

pointed  out  in  this  manual  are  not  exhaustive  for  all  possible 
situations. Although we have designed our product to be as safe as 
possible,  persons  operating  and  maintaining  the  device  should 
strictly follow all safety rules in the operation/maintenance area.

 

Содержание EVP56-100

Страница 1: ... H 56 100 Electric Pump for light oil diesel oil INSTRUCTION MANUAL Contents 1 Safety precautions 1 3 Before using the device 4 Parts description 5 Place and way of use 6 Specifications drawings 7 Warranty and service ...

Страница 2: ...essary BEFORE USING THE DEVICE Read and strictly follow instructions on liquid s use Refer to information on liquid you wish to transfer Read it carefully and use the liquid properly In case of direct contact with liquid act immediately In case of liquid ingestion skin contamination etc immediately proceed with liquid s safety procedures and seek medical attention Not following the instructions ma...

Страница 3: ... matters are restricted to authorized experts Safety precaution when changing the liquid When changing the liquid you are going to transfer remember to remove the previous liquid and clean the device Not doing so may result in dangerous chemical reactions Request technical service whenever required When the device stops operating or operates in a strange manner immediately turn off the device and ...

Страница 4: ...dry state Do not exceed the supply power voltage range In case of device s malfunction If you experience device s malfunction immediately disconnect the device from the power source Contact the vendor or manufacturer Pump s permitted temperature range 5 60 Please remember that the safety measures and warnings pointed out in this manual are not exhaustive for all possible situations Although we hav...

Страница 5: ...PARTS DESCRIPTION Switch ON OFF Connection Part Delivery Rc1 Electric Power Cord AC100 1 6m Connection Part Suction Rc1 4 ...

Страница 6: ...e with low humidity and dust concentration If the pump has been switched on and is operational yet no suction occurs pour approx 240cc of transferred liquid into pump s delivery outlet before turning the pump on Avoid running the pump in a dry state as it may be damaging to its inner components 2 Start the device by using a switch on the back of the pump 5 1 Check the installation Hoses piping ...

Страница 7: ... Pressure By pass Filter Connection Weight L min MPa Kg EVP56 100 100V Diesel Oil Kerosene Light Oil FC Vane Self priming 46 0 21 Internal Internal 100 micron Rc1 9 1 Motor Specifications Type Voltage Frequency Power Continuous Operation V Hz KW A Single Phase Current AC100 50 60 0 37 0 45 Possible DIMENSIONS WARRANTY AND SERVICE 6 ...

Страница 8: ...not be free In both cases covering shipment and shipment related costs is customer s responsibility The product s breakdown has been reported within 12 months from the date of purchase but The product has been misused The product has been repaired serviced however not by AQUASYSTEM The product has not been stored or maintained properly There are no documents receipts which would prove the purchase...

Отзывы: