ADSP7000634
rev. 1.3
23/09/2020
18/36
3.3.6
R
ESETTING
D
EFAULT
P
ARAMETERS
From the
r.P.d
entry you will be able to reset the equipment default parameters (refer to the
Default Parameters
Table
in Attachment F). If you choose to reset the initial values, you will go back to the initial display. See Fig. 17.
Once you confirm with
YES
, you cannot go back.
Fig. 17- Default parameters reset
3.3.7
S
ETTINGS
M
ENU
From the
InP
entry of the Programming Menu, via the
Enter
key, you can access the
Settings Menu.
From the Settings Menu you can carry out the following operations (refer to
Figure 18
):
Set the password to access the Programming section,
PAS
: with
Enter
you can go to the
“000” selection
page,
with the
▲
and
▼ keys you can increase/decrease the value displayed and with
Enter
you can scroll
through the figure you intend to set. After choosing the new password, press
Enter
for 3 seconds to go back
to the
PAS
entry;
Enable the pump stop in the case of a
St.P
level alarm: to access and exit the submenu, use
Enter,
to scroll
through “
YES/no
” use the
▲
and
▼ keys;
Choose whether to disable the over-dosage alarm OFA
OF.r
only from the switch by placing it in the OFF
position, or to disable it from the switch as well as when turning off the equipment,
Aut
: to enter and exit the
sub-menu, use the
Enter
key, to scroll “
OFF/Aut
” use
▲
and
▼;
Select the time frame to control the OFA alarm,
OFA
, within a range of 1-999 seconds or disable it (
OFF
): to
enter and exit the submenu use
Enter,
to scroll through the values use the
▲
and
▼ keys;
Set the time of the pump maintenance alarm,
O.F.d
, from 0 (disabled) to 999 hours, based on the following
format:
-
h.mm
up to 9 h and 59 m
-
hh.m
up to 99 h and 59 m (minutes expressed in tens)
-
hhh
up to 999 h
To enter and exit the submenu use
Enter
and increase/decrease the value with the
▲
and
▼ keys;
Choose if you want to make the Set-point,
OnL
, a value that can be changed on-line or from the User Menu:
to enter and exit the sub-menu use
Enter,
to scroll through “
YES/no
” use the
▲
and
▼ keys;
Enable the
A.bu
buzzer when an alarm is activated: to enter and exit the sub-menu use
Enter,
to scroll
through “
YES/no
” use the
▲
and
▼ keys;
Set the temperature coefficient value
C.d.t (see Operation, Section 3.1)
from 0.0 to 5.0 (percentage value
from 0.0% to 5.0%): to enter and exit the sub-menu use the
Enter
key, the value is increased/decreased by
using the
▲
and
▼ keys;
Set the opening time of the solenoid valve
t.on,
in the case of dosage without the peristaltic pump (solid
detergent), in the range of 0-30 seconds: to enter and exit the sub-menu, use the
Enter
key, the value is
increased/decreased by using the
▲
and
▼ keys;
Set the closing time of the solenoid valve
t.oF,
always in the case of dosage without the peristaltic pump
(solid detergent), in the range of 0-30 seconds: to enter and exit the sub-menu, use the
Enter
key, the value
is increased/decreased by using the
▲
and
▼ keys;
Содержание DGTEC CD
Страница 25: ...ADSP7000634 rev 1 3 23 09 2020 25 36 ANNEX A Overall dimensions ...
Страница 27: ...ADSP7000634 rev 1 3 23 09 2020 27 36 ANNEX C Exploded views ...
Страница 33: ...ADSP7000634 rev 1 3 23 09 2020 33 36 ANNEX G Menu Layouts Initial Menu User Menu ...
Страница 34: ...ADSP7000634 rev 1 3 23 09 2020 34 36 Programming Menu Statistics Menu Settings Menu ...
Страница 36: ...ADSP7000634 rev 1 3 23 09 2020 36 36 DGTEC CD ...