background image

7

USER MANUAL FOR AC-2

6

 POOL FILTER 

during the set operation periods. 

Set automatic operation periods: 

Remark: 

Before setting the automatic operation periods, set the water temperature lower than 

the actual water temperature. Otherwise, the pump 1 will work all the time, and can’t 

controlled by operation periods time. “A/M” key shows red light means the automatic mode; 

“A/M” key has no light means the manual mode.

 

Set the first operation period: 

¾

Step 1: 

Press “A/M” key to switch the pump 1 to the automatic mode (“A/M” key shows green).

¾

Step 2: 

Set the start time: Press “T1” key, then press “A/M” key (The “A/M” key will lit, it means to

set the start time.), the hour/minute digit will be flashing. Press 

“+”“-”

 to adjust the hour/minute.

Press “T1” key again, the minute/hour digit will flashing, press 

“+”“-”

 to adjust the minute/hour. No

action within 5 seconds, the start time will be stored automatically.

¾

Step 3:

 Set the end time: Press “T1” key, then press “A/M” key (The “A/M” key has no light, it

means to set the end time.), the hour/minute digit will be flashing. Press 

“+”“-”

 to adjust the

hour/minute. Press “T1” key again, the minute/hour digit will flashing, press 

“+”“-”

 to adjust the

minute/hour. No action within 5 seconds, the start time will be stored automatically.

     

PLEASE SET T2 AND T3 OPERATING PERIOD AS ABOVE OPERATION INSTRUCTIONS.

 

REMARK:

 If it is no need to set the time in any of the 3 periods, just set the time to “00:00” in 

that period to avoid it.

 

Cautions before first using: 

‹

 

Before running the device for the first time, turn on the ball valve of the pipe and fill water until the 
equipment box pipe are full of water and then turn off the ball valve. 

‹

 

When it is ready to start running, press the

 “ON/OFF”

 key on control panel for several times until 

the circulation pump can work normally because there may be some air inside the pipes and pump for 
first runnin

g.  

1.

Setting device running:

‹

 

Manufacturer recommends

running time=water temperatur/2 (h)

‹

 

For example

  if water temperature is 24

0

C then the running time is 24/2=12hours

Recommending to set time as

8

00-20

00 

The device can do filtering at night time if noise pollution is not considered. 

Содержание AC-26

Страница 1: ...USER MANUAL FOR AC 26 POOL FILTER 1 AC 26 POOL FILTER INSTALLATION OPERATION MANUAL ...

Страница 2: ...t includes 1 circulating pump 25m3 h and the pipe which connects to the Filter Area And the ozonater pipe is also in the area Swimming pool water goes into the 1 skimmer active door of the filter area go through the 2 filter drums into the pumps and then return to pool via the jets The pumps can be controlled manually or automatically by the digital timer Optional RF Remote control The features of...

Страница 3: ...ovation pool Technical specification Power supply 220V 50Hz Underwater light 7 5W 12VDC Power consumption 1 6kw Pump outlet 1 5 Flow rate 25cbm h Pump inlet 2 Ozone Generator 500mg h Dimension 1440 760 1020mm Filtration precision 75μm Net weight 90 kgs INSTALLATION INSTRUCTION 1 Layout to put the plant NOTE before the paving of the pavement of the swimming pool please connect a anti corrosive and ...

Страница 4: ...USER MANUAL FOR AC 26 POOL FILTER 4 Fig 2 Dimensions Fig 3 Plan Layout ...

Страница 5: ...SER MANUAL FOR AC 26 POOL FILTER Ⅱ Electrical installation instruction NOTE Electrical installation must be operated by the qualified technician Fig 4 Wiring of Connection box Fig 5 Wiring of control box 6 ...

Страница 6: ... press T C key for 3 seconds and loosen the hand the panel screen will display system clock time and hour minute digit flashing press to adjust the hour minute Press T C key again the minute hour digit will flashing press to adjust the minute hour It will store and return to the previous working status after flashing 5 seconds A M key Long press A M key to to switch the pump 1 between manual worki...

Страница 7: ... it means to set the end time the hour minute digit will be flashing Press to adjust the hour minute Press T1 key again the minute hour digit will flashing press to adjust the minute hour No action within 5 seconds the start time will be stored automatically PLEASE SET T2 AND T3 OPERATING PERIOD AS ABOVE OPERATION INSTRUCTIONS REMARK If it is no need to set the time in any of the 3 periods just se...

Страница 8: ...blocked Clear out the leaves and garbage of the filter basket Water line is too low Fill up the pool to 3 4 skimmer Incorrect voltage Check the voltage of power supply Pump is working but the water flow is small Outlet is blocked Take out front part of jet to check for debris Water is found on the bottom of the technical house Pump pipe or union part is leaking Tighten the pump union re seal the c...

Страница 9: ...ntenance and repair Please read this manual before maintenance and repair z Please contact the manufacturer or the nearest dealer when there is incorrect operation or damage 2 NOTES FOR INSTALLATION AND ASSEMBLY z Before connecting the cable to device please check if it is installed and connected correct z Very important do not let device and electrical parts get wet when the electricity power is ...

Отзывы: