Changing the Lamp
2. Place the Statuary Unit on a sturdy work area with the mouth facing down.
1.
Unplug the Statuary Unit from power source and drain the water out.
3. Unscrew the Davis Connector located just above the Transformer Cap. This
will allow the Transformer Cap to turn without kinking the electrical cord.
CAUTION:
Always turn off the pump and disconnect the electricity from the unit prior to any
maintenance.
WARNING: Use only genuine AQUA ULTRAVIOLET replacement parts when changing your
lamp. This is a specialized lamp, while others may look similar they are not the same. Other
lamps will not produce the same result and can damage your Statuary UV.
13
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
4. Twist off the Transformer Cap.
Содержание STATUARY 15 Watt 1/L