OPERATION AND MAINTENANCE MANUAL
]
[
V-1.16
]
AQUA spa
13
NOTE:
For correct operation, if you wish to pilot the filtration pump using an external relay/remote
switch, eliminate condenser
C4.
This operation must be carried out by qualified staff, at an assistance centre.
Level-control solenoid valve connection
Connect the solenoid valve power supply cable to the
OUT 3 clamp (N
and
F)
.
Output protected with a safety fuse. If the fuse blows, a red led will light up in the level-control
solenoid valve indicator light on the front synoptic panel.
ATTENTION: the output voltage of the OUT3 clamp is 220Vac. To connect the solenoid valve at
24vac use the designated solenoid valve transformer kit TR324 code 100100835
Level probes connection
Use level probes, available separately, code: 108100816
Use the black cable and the blue cable of the level probe. The brown cable is not required.
Connect pump protection level probe (A) to clamps
11
and
12.
Connect level-control probe (B) to clamps
13
and
14.
Connect overflow level probe (C) to clamps
15
and
16.
If it is necessary to run the device temporarily without level probes, jumper clamps 15 and 16
Description of protection fuses
CODE
FUNCTION
FUSE VALUE
F5
Lighting fuse
250 V - T 3.15 A
F6
Filtration pump fuse
250 V - T 16 A
F8
Level-control solenoid valve fuse
250 V - T 3.15 A
F9
Internal electronic fuse
250 V - T 1 A
CAUTION!! Wiring and connection operations must be carried out by qualified staff. Only use
pumps with internal over-heating protection systems.