HOUSING INSTALLATION

Housing Installation

 – see Diagram 1

  

Aqua-Star Housing

 should be tied to the steel reinforcing, 

before concreting the pool. A 

red

 

Concrete Cap

 is supplied 

to fit inside the front of the Housing prior to concreting.

2

  The 

Housing 

has two conduit connection points to 

accept rigid PVC conduit, do not use flexible conduit. 
Choose the appropriate provision for the situation and run 
conduit above water level to form an anti-siphon loop. Top 
provision accepts 20mm conduit or 25mm conduit fitting. 
Rear provision accepts 20mm coupling. If using the 

Rear 

Provision

, be sure to plug the 

Top Provision

 using a 25mm 

conduit cap.

3

  Use tie wire or cable ties through the holes on the outer 

perimeter of the 

Housing

 to securely fasten it to the steel 

reinforcing bars. Position the 

Housing 

so that the front will 

finish level with the concrete. 

4

  It is very important to locate 

Housing

 at a suitable location 

and depth to allow for future servicing of the pool light. 
Excavate sufficiently around the rear of the 

Housing

 to allow 

approximately 100mm of concrete to encase it. If pool is out 
of ground and fully formed, ensure the formwork allows for 
concrete to encase the 

Housing

.

5

  During pouring/spraying, concrete should be undercut 

around the front perimeter of the 

Housing

 to allow for a 

construction adhesive to be applied prior to the application 
of the internal pool surface.

6

  Concrete should be applied to reduce the likelihood of 

a void occurring on the underside of the 

Housing

. Once 

concrete has cured, construction adhesive must be applied 
around the 

Housing

 to seal it to the concrete. 

Diagram 1 – After Concreting

Concrete

Undercut

Alternative 
Conduit 
Provision

100mm  
Concrete
Encasement 

TECHNICAL SPECIFICATIONS AQUA-STAR HALOGEN FLUSH MOUNTED POOL LIGHTS

Nominal Supply Voltage:   12V AC 50/60 Hz 
Voltage Tolerance: 

+2%, -10%

Protection Rating:  

IPX8 (to 2.0m depth)

Temperature Range:  

-10°C ~ +40°C water temperature

Power Consumption: 

50 VA

Lamp Life: 

2,000 hours

Light Output (typical): 

900 Lumens

Aqua-Star Halogen Lights must only be operated underwater as they are water-cooled. 
Install in an accessible location, ensure that sufficient cable is wound up inside the housing to allow the light to be 

floated to the deck level. If being installed facing up, ensure that there is minimum 100mm of water cover and change 

globe to max 30 watts.
Aqua-Star Halogen Pool Lights can be installed on a vertical or horizontal pool surface. Up to 1.6m of cable can be 

wound up inside the Concrete Housing.

Содержание AQUA-STAR

Страница 1: ...PLEASE NOTE THESE INSTALLATION INSTRUCTIONS APPLY TO AQUA STAR HALOGEN LIGHTS FOR CONCRETE POOLS ONLY Housing Red Concrete Cap Adjustable Dress Ring Screw Kit CODE DIMENSIONS mm A 171 B 169 C 120 max D 79 E 63 F 143 G 120 H 135 K Accepts 20mm conduit or 25mm socket L Accepts 20mm socket Aqua Star Flush Mounted Pool Light Concrete Dimensions for the major components are obtained by cross referencin...

Страница 2: ...encase it If pool is out of ground and fully formed ensure the formwork allows for concrete to encase the Housing 5 During pouring spraying concrete should be undercut around the front perimeter of the Housing to allow for a construction adhesive to be applied prior to the application of the internal pool surface 6 Concrete should be applied to reduce the likelihood of a void occurring on the unde...

Страница 3: ...ment If Housing protrudes out from the concrete a maximum of 20mm can be cut off from the front If the housing has been set back too far in the wall then a special extension ring P N ASL 076 is available The eyeball feature on the Adjustable Dress Ring allows adjustment so that the Adjustable Dress Ring face can be aligned flush with the anticipated pool interior finish even if the Housing is out ...

Страница 4: ...UA STAR GLOBE CHANGING INSTRUCTIONS 1 Unscrew the 2 stainless steel screws remove stainless steel trim ring and or coloured lens if fitted 2 Float the light to the surface and place on deck 3 Grip the rear black nut with multi grips or use a screwdriver through the two holes in the black nut and turn anticlockwise whilst holding the white body of the light This will remove the nut from the body ex...

Отзывы: