Delivery Address:

PO Box 6767
Blacktown DC NSW 2148

Aqua-Pure

®

 Water Filters

Reply Paid 6767 
Blacktown NSW 2148

AP9250 Stage 1 Cartridge

3.  Remove used stage 1 cartridge by turning it to the left. (Approximately 1/4 turn) 

4.   Hold cartridge fi rmly and pull downwards. (Be aware there will be  
 

approximately 15ml / 1 tablespoon of water spill (ref fi g a).

5.   Drain and dispose of the used cartridge.

6.  Remove red plastic cover on new AP9250 stage 1 cartridge and 
 

insert cartridge into the head cavity (ref fi g b).

7.   Turn cartridge to the right, until it stops. (Approximately 1/4 turn)

AP9250 Stage 2 Cartridge

8.  Remove used stage 2 cartridge by turning it to the left. (Approximately 1/4 
 turn)

9.   Hold cartridge fi rmly and pull downwards. Be aware there will 
 

be  approximately 15ml / 1 tablespoon of water spill (ref fi g c).

10. Drain and dispose of the used cartridge.

11. Remove red plastic cover on new AP9250 stage 2 cartridge and 
 

insert cartridge into the head cavity (ref fi g d).

12. Turn cartridge to the right, until it stops. (Approximately 1/4 turn)

13. Slowly turn water supply on. Leave fi lter tap at ON position and allow water to 
 

run for a minute to fl ush the new cartridge. 

14. Reset the LCD fi lter monitoring system.

a.

b.

c.

d.

GUIDE TO REPLACE YOUR CARTRIDGE

The Aqua-Pure

®

 AP9200

+

 series Twin NEP head has auto shut off feature and is designed for your safety. NEP head’s auto shut off feature safeguards against human error 

such as accidental removal of cartridge when water supply is not isolated.

In the event that the cartridge is removed without isolating water supply, the auto shut off head mechanism will terminate the incoming water supply and vent off residual 
water pressure through the drain tube. Approximately 50ml / 3 tablespoons of water will drain from the tube.

While this feature is built into every single NEP head, Aqua-Pure

®

 recommends water supply to be isolated and pressure relieved prior to cartridge change before proceeding 

with cartridge replacement as per steps below.

1.  Turn water supply off. If there is no isolation tap, turn off mains water supply.

2.  Turn fi lter tap on to check water supply is off and to release any residual water.  Leave fi lter tap in ON position.

NOTE: 

Aqua-Pure

®

 fi lter systems are designed for ease of installation. However, post-installation inspections are highly recommended. Check for leaks immediately after installation and once 

again after 24 hours. If leaks are detected, turn off water supply, drain water and inspect the leaks. If problem persists, contact the installer/ plumber for rectifi cation.

Содержание AP9200+

Страница 1: ... heart every 12 months The heart of an AP9200 filter system is the AP9250 stage 1 and 2 filter cartridges which has a recommended maximum life of 12 months The life and performance of a cartridge may vary depending on the volume and quality of the incoming water supply being filtered Your cartridge may need replacing earlier than 12 months if you notice a reduced flow from the filter tap or the re...

Страница 2: ...g 8 b Screw MFCV to water supply tap Hand tighten sufficiently to avoid leaking ref fig 9 fig 8 fig 9 fig 7 fig 10 CAUTION Do not overtighten MFCV 5 Reconnect dishwasher hose to end of MFCV 4 ref fig 2 6 If you do not have a dishwasher or a mixer tap screw the black stopper plug removed in above and screw into the end of the MFCV 4 ref fig 10 fig 6 fig 11 fig 12 Where to drill MOUNTING THE SYSTEM ...

Страница 3: ...side of the monitor will light up all 12 bars and you will hear one long buzz followed by three short buzzes NOTE The sequence in which the F1 and F2 buttons are activated is not important and will not affect the performance of the monitoring system The left column of the LCD display indicates a time months based monitor and the right side LCD indicates a capacity gallons litres based monitor When...

Страница 4: ...STS TABLE C1 This appliance meets the domestic water treatment appliance Standards AS NZS 3497 and AS NZS 4348 for the following water treatment process Class Treatment Type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is ticked n a II Microbiological Treatment II a Bacteria Removal Will remove inactive bacteria n a II b V...

Страница 5: ...the LCD filter monitoring system a b c d GUIDE TO REPLACE YOUR CARTRIDGE The Aqua Pure AP9200 series Twin NEP head has auto shut off feature and is designed for your safety NEP head s auto shut off feature safeguards against human error such as accidental removal of cartridge when water supply is not isolated In the event that the cartridge is removed without isolating water supply the auto shut o...

Страница 6: ...ory conditions actual performance may vary System must be installed and operated in accordance with manufacturer s recommended procedures and guidelines Failure to do so may void warranty See warranty card for details CAUTION This filter system or cartridge is designed to be installed on the cold water line Do not install on hot water line WARNING AS3497 1998 requires dual backflow prevention and ce...

Отзывы: