 7.  After adjusting the fi lter tap to face the desired direction, tighten the hex nut with 
 

a padded adjustable wrench or spanner.

AP9200

+

 FILTER SYSTEM HEAD

AP9250 Stage 1 
Filter Cartridge

AP9250 Stage 2 
Filter Cartridge

AP9250 Stage 1 
Filter Head

Water Inlet

Water Outlet

Pressure Relief Outlet

LCD Display

Battery Cover

Shroud

LCD Display
Activation Button

Mounting Bracket

AP9250 Stage 2
Filter Head

CONNECTING THE LCD FILTER MONITORING 
SYSTEM

 1.  Connect the black connector (light indicator wire) to the black connector on the 
 shroud.

2.  Connect the white connector (capacity / time indicator wire) on the bracket to the 
 

white connector on the shroud.

3.  Slide the shroud onto the bracket as shown in the 
 

direction of the arrow (ref fi g 22 and 23).

fi g. 22

fi g. 23

ACTIVATION AND RE-SETTING OF LCD 
FILTER MONITORING SYSTEM ON SHROUD

The monitoring system is operated by two 
buttons (F1 and F2) for system start-up after 
initial installation and subsequent re-setting after 
each fi lter cartridge change-out (ref fi g 24).

fi g. 24

1.  Remove battery cover.

2.  F1 button - After installation of your new AP9200

+

 system or after replacing any 

 

of the two fi lter cartridges, press F1 button and hold for at least 4 seconds. The 

 

LCD display on the left side of the monitor will light up all 12 bars and you will hear 

 

one long buzz followed by three short buzzes.

3.  F2 button - After installation of your new AP9200

+

 or after replacing any of the 

 

two fi lter cartridges, press F2 button and hold for atleast 4 seconds. The LCD 

 

display on the right side of the monitor will light up all 12 bars and you will hear 

 

one long buzz followed by three short buzzes.

NOTE

: The sequence in which the F1 and F2 buttons are activated is not important and will not 

affect the performance of the monitoring system.

The left column of the LCD display indicates a time (months) based monitor and the right side 
LCD indicates a capacity (gallons/litres) based monitor.

When either of the displays is left with one lighted bar, the drinking water fi lter tap light indicator 
will turn from blue to red, indicating that the fi lter cartridge should be changed. When this last 
lighted bar is depleted, the audio alarm will be activated 2 seconds after the drinking fi lter tap 
is turned on each time. The alarm will remain activated for a period of 10 seconds until the fi lter 
cartridges are changed and the monitoring system re-set.

4.  To click the status of the fi lter  system, press the “push” button on the LCD 
 

display control panel (ref fi g 25).

5.  From underneath sink, slide the white wire holder through the 1/4” blue tubing 
 

and threaded brass stem. The light indicator wire should be threaded through the 

 

side hole of the white wire holder.

6.  Slide in the star washer and hex nut onto the threaded brass stem and tighten by 
 

hand (ref fi g 18).

 

NOTE: 

For correct installation, please refer to fi g 18.

Filter Tap

LED Indicator Ring

Rubber Gasket

Bench Top / Sink

Wire Holder

Star Washer

Hex Nut

Light Indicator Wire 
(To shroud cover)

Filter Tap Tube

1/4” Tube Connector

fi g. 18

BATTERY INSTALLATION

 1.  Slide the battery cover out (ref fi g 19).

fi g. 19

2.  Lift the battery cover (ref fi g 20).

fi g. 20

3.  Install three AA size alkaline batteries (use only alkaline battery)

4.  Place the cover back (ref fi g 21).

fi g. 21

fi g. 25

Содержание AP9200+

Страница 1: ... heart every 12 months The heart of an AP9200 filter system is the AP9250 stage 1 and 2 filter cartridges which has a recommended maximum life of 12 months The life and performance of a cartridge may vary depending on the volume and quality of the incoming water supply being filtered Your cartridge may need replacing earlier than 12 months if you notice a reduced flow from the filter tap or the re...

Страница 2: ...g 8 b Screw MFCV to water supply tap Hand tighten sufficiently to avoid leaking ref fig 9 fig 8 fig 9 fig 7 fig 10 CAUTION Do not overtighten MFCV 5 Reconnect dishwasher hose to end of MFCV 4 ref fig 2 6 If you do not have a dishwasher or a mixer tap screw the black stopper plug removed in above and screw into the end of the MFCV 4 ref fig 10 fig 6 fig 11 fig 12 Where to drill MOUNTING THE SYSTEM ...

Страница 3: ...side of the monitor will light up all 12 bars and you will hear one long buzz followed by three short buzzes NOTE The sequence in which the F1 and F2 buttons are activated is not important and will not affect the performance of the monitoring system The left column of the LCD display indicates a time months based monitor and the right side LCD indicates a capacity gallons litres based monitor When...

Страница 4: ...STS TABLE C1 This appliance meets the domestic water treatment appliance Standards AS NZS 3497 and AS NZS 4348 for the following water treatment process Class Treatment Type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is ticked n a II Microbiological Treatment II a Bacteria Removal Will remove inactive bacteria n a II b V...

Страница 5: ...the LCD filter monitoring system a b c d GUIDE TO REPLACE YOUR CARTRIDGE The Aqua Pure AP9200 series Twin NEP head has auto shut off feature and is designed for your safety NEP head s auto shut off feature safeguards against human error such as accidental removal of cartridge when water supply is not isolated In the event that the cartridge is removed without isolating water supply the auto shut o...

Страница 6: ...ory conditions actual performance may vary System must be installed and operated in accordance with manufacturer s recommended procedures and guidelines Failure to do so may void warranty See warranty card for details CAUTION This filter system or cartridge is designed to be installed on the cold water line Do not install on hot water line WARNING AS3497 1998 requires dual backflow prevention and ce...

Отзывы: