background image

AP9200

+

 Water Filter System

Installation and operating instructions

Not even an Aqua-Pure

®

 fi lter can make unsafe water safe

The  water fi lter system should only be used on water that is 
microbiologically safe – that is, water that has been adequately chlorinated 
or disinfected. Additional equipment (such as a chlorine injection system or 
an ultraviolet steriliser) will be required for unsafe water.

It works best when it’s used

If the Aqua-Pure

®

 water fi lter system has not been used for more than one 

day, you will need to fl ush 1 to 2 litres of water through the system before 
using the water. The  requires a minimum water supply pressure 
of 172 kPa (25 psi) and not exceed a maximum water pressure of 862 kPa 
(125 psi). A 650 kPa (94 psi) pressure limiting valve must be installed on 
the inlet side of this system (see below).

What a valve

The   system has been supplied with an Aqua-Pure

®

 650 kPa

98210 Multi-Function Control Valve (MFCV) as standard equipment. 
This valve must be installed as detailed in the installation drawings and 
instructions, to provide:

• Flow restriction 

• 650 kPa pressure limiting

• Dual check backfl ow prevention 

• Anti-hammer protection for the fi lter system

This valve is fi tted with a Particle Removal Screen on the inlet side to protect 
the intricate mechanism from debris that may be in the water supply. This 
screen must remain in place at all times. Failure to comply with these 
requirements will void the warranty.

Have a change of heart every 12 months

The heart of an  fi lter system is the AP9250 stage 1 and 2 fi lter 
cartridges, which has a recommended maximum life of 12 months. The 
life and performance of a cartridge may vary depending on the volume and 
quality of the incoming water supply being fi ltered. Your cartridge may need 
replacing earlier than 12 months if you notice a reduced fl ow from the fi lter 
tap, or the return of an unpleasant taste/odour to the fi ltered water.

Worth doing…worth doing properly

Installation of the   fi lter system must comply with any existing 
state or local plumbing codes, some of which require installation by a 
licensed plumber. 

WARNING:

 For correct operation of this appliance, it is essential that these 

installation and operating instructions be strictly observed.

CAUTION:

 

Do not use with water that is microbiologically unsafe or with 

water of unknown quality without adequate disinfection before or after the 
system. Systems certifi ed for cyst reduction may be used on disinfected 
water that may contain fi lterable cysts.

PREPARATION

1.   Check your  Aqua-Pure  component identifi cation and content checklist:

 REF 

DESCRIPTION 

QTY 

PART NO

  1 

3M DWS Twin Filter System Head 

XA006464243

  2 

AP9250 Stage 1 

1

  

Replacement 

Cartridge 

  3 

AP9250 Stage 2 

1

  

Replacement 

Cartridge 

  4 

98210 MFCV 650 kPa 

AK200094782

  5 

1/2” BSP X 1/4” BSP Brass Nipple 

AK200093396

  6 

Adaptor 1/4” BSP X 1/4” Tube 

AK200093156

  7 

1/4” Tube Food Grade 

AK200072572

  8 

QC 1/4”T Straight Connector 

AK200093842

  9 

NEP Bypass Plug 

70020160308

  10 

Thread Seal Tape Certifi ed 

AK200095102

 11 

13-DF501/801 

Filter 

Tap 

AK200118698

1

7

9

8

11

10

2

4

5

3

6

AK200125875

WATER FILTERS

Содержание AP9200+

Страница 1: ... heart every 12 months The heart of an AP9200 filter system is the AP9250 stage 1 and 2 filter cartridges which has a recommended maximum life of 12 months The life and performance of a cartridge may vary depending on the volume and quality of the incoming water supply being filtered Your cartridge may need replacing earlier than 12 months if you notice a reduced flow from the filter tap or the re...

Страница 2: ...g 8 b Screw MFCV to water supply tap Hand tighten sufficiently to avoid leaking ref fig 9 fig 8 fig 9 fig 7 fig 10 CAUTION Do not overtighten MFCV 5 Reconnect dishwasher hose to end of MFCV 4 ref fig 2 6 If you do not have a dishwasher or a mixer tap screw the black stopper plug removed in above and screw into the end of the MFCV 4 ref fig 10 fig 6 fig 11 fig 12 Where to drill MOUNTING THE SYSTEM ...

Страница 3: ...side of the monitor will light up all 12 bars and you will hear one long buzz followed by three short buzzes NOTE The sequence in which the F1 and F2 buttons are activated is not important and will not affect the performance of the monitoring system The left column of the LCD display indicates a time months based monitor and the right side LCD indicates a capacity gallons litres based monitor When...

Страница 4: ...STS TABLE C1 This appliance meets the domestic water treatment appliance Standards AS NZS 3497 and AS NZS 4348 for the following water treatment process Class Treatment Type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is ticked n a II Microbiological Treatment II a Bacteria Removal Will remove inactive bacteria n a II b V...

Страница 5: ...the LCD filter monitoring system a b c d GUIDE TO REPLACE YOUR CARTRIDGE The Aqua Pure AP9200 series Twin NEP head has auto shut off feature and is designed for your safety NEP head s auto shut off feature safeguards against human error such as accidental removal of cartridge when water supply is not isolated In the event that the cartridge is removed without isolating water supply the auto shut o...

Страница 6: ...ory conditions actual performance may vary System must be installed and operated in accordance with manufacturer s recommended procedures and guidelines Failure to do so may void warranty See warranty card for details CAUTION This filter system or cartridge is designed to be installed on the cold water line Do not install on hot water line WARNING AS3497 1998 requires dual backflow prevention and ce...

Отзывы: