background image

4

*Sold separately

For extended life and ease of assembly 

For extended life and ease of assembly 

and disassembly during maintenance, it is 

and disassembly during maintenance, it is 

recommended that o-rings are lubricated with an 

recommended that o-rings are lubricated with an 

aquarium safe o-ring lubricant such as AquaLube*. Lubricating the 

aquarium safe o-ring lubricant such as AquaLube*. Lubricating the 

o-rings will also minimise the chance of parts seizing leading to accidental 

o-rings will also minimise the chance of parts seizing leading to accidental 

breakages during maintenance.

breakages during maintenance.

To remove the o-ring, 

To remove the o-ring, 

use a plastic card, such 

use a plastic card, such 

as a credit card to gently 

as a credit card to gently 

lever the o-ring up and 

lever the o-ring up and 

over the lip of its seat. 

over the lip of its seat. 

Then roll it off the part.

Then roll it off the part.

Cleaning and Lubricating of O-Rings

Cleaning and Lubricating of O-Rings

Rinse in fresh water to 

Rinse in fresh water to 

remove any particles 

remove any particles 

attached. Dry the o-ring.

attached. Dry the o-ring.

Put a small amount of 

Put a small amount of 

lubricant* and smear it 

lubricant* and smear it 

over the o-ring so that it 

over the o-ring so that it 

is covered by a thin film.

is covered by a thin film.

CORRECT DISPOSAL OF THIS PRODUCT

CORRECT DISPOSAL OF THIS PRODUCT

Disposal of used Electrical & Electronic Equipment (Applicable in the European Union 

and other European countries with separate collection systems)

This symbol on the product or on its packaging indicates that the product must not be disposed of 

with normal household waste. Instead, it is your responsibility to dispose of your waste equipment by arranging 

to return it to a designated collection point for the recycling of waste electrical and electronic equipment. By 

separating and recycling your waste equipment at the time of disposal you will help to conserve natural resources 

and ensure that the equipment is recycled in a manner that protects human health and the environment. 

For more information about recycling this product, please contact your local city office, your household waste 

disposal service or the shop where you have purchased the product.

Содержание PHX 100

Страница 1: ...s very important to remove dirt moisturiser and other impurities All species of fish have specific requirements for their care Please seek advice from your Aqua One retailer for correct care requirements and species compatibility Instruction version 17 12 2019 Australia www aquaone com au New Zealand www aquaone co nz United Kingdom www aquaone co uk All other countries www aquaone com au CUSTOMER...

Страница 2: ...nsure input voltage is the same voltage as your local power supply Never yank the cable to pull it from the socket Pull the plug carefully to disconnect A G F C I Ground fault circuit interrupter surge protector is recommended for all electrical appliances Water and electricity can be dangerous Do not attempt repairs yourself Return the appliance to an authorised service facility for repair All pr...

Страница 3: ...way or product malfunction in any way or if the unit is damaged and requires if the unit is damaged and requires replacement contact the retailer replacement contact the retailer where the product was purchased for where the product was purchased for inspection inspection PHX 100 0 7m 8 5l x 4d x 6h cm 350 l hr 3 5w PHX 150 1 2m 10 5l x 7 5d x 7 5h cm 600 l hr 7 2w PHX 200 1 5m 12 5l x 8 5d x 9h c...

Страница 4: ...sh water to remove any particles remove any particles attached Dry the o ring attached Dry the o ring Put a small amount of Put a small amount of lubricant and smear it lubricant and smear it over the o ring so that it over the o ring so that it is covered by a thin film is covered by a thin film CORRECT DISPOSAL OF THIS PRODUCT CORRECT DISPOSAL OF THIS PRODUCT Disposal of used Electrical Electron...

Страница 5: ...onents Powerhead Components 5 Pump 6 Impeller 7 Impeller cover 8 Intake strainer 9 Suction cups x4 What s In The Box PHX 100 Major Components Major Components 1 Powerhead 2 9mm push fit outlet 3 12mm push fit outlet 4 Inlet hose adapter 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 ...

Страница 6: ... 9 Intake strainer 10 Flow controler 10 10 6 6 7 7 8 8 9 9 Know Your Powerhead What s In The Box PHX 150 200 300 Major Components Major Components 1 Powerhead 2 Suction cups x4 3 12mm threaded outlet 4 15mm threaded outlet 5 Undergravel adapter 1 1 2 2 3 3 4 4 5 5 except PHX 300 ...

Страница 7: ...low Control PHX 150 200 300 Flow Control The attachements that come with the filter will assist in directing the water where you need Speak to your Aqua One retailer for any hose fittings or additional adapters you may need Attachements Attachements The powerhead must not be operated out of the water The powerhead must not be operated out of the water this can cause the motor to overheat this can ...

Страница 8: ...e become stiff with use soak cups may have become stiff with use soak suction cups in warm tap water not boiling to suction cups in warm tap water not boiling to soften them for 10 minutes If they still will not soften them for 10 minutes If they still will not hold then they should be replaced hold then they should be replaced Suction Cups Suction Cups If you are having trouble disconnecting If y...

Страница 9: ... impeller cover and impeller A small pair of pliers can help to grip the impeller making it easier to remove Use a pipe brush to clean the impeller well and internal channels of the powerhead Wipe the outside with a cloth to remove any buildup Do not use abrasive materials or chemicals not intended for aquarium use Reassemble the powerhead and place it back into the original position Make sure you...

Страница 10: ...Flow Filter Intake Ensure that the powerhead is mounted securely to the aquarium wall and the intake strainer is firmly attached and clear of debris The external flexible cables of this unit cannot be replaced The external flexible cables of this unit cannot be replaced if the cable is damaged the part should be replaced if the cable is damaged the part should be replaced No Water Flow No Water Fl...

Страница 11: ...ing Pump Problems If you are If you are having having problems problems with the with the pump follow these pump follow these steps to help diagnose steps to help diagnose the problem Most the problem Most common pump common pump problems can be found problems can be found with these steps with these steps The PHX 100 does not The PHX 100 does not have a removable shaft have a removable shaft ther...

Страница 12: ...electrical cord or plug k vermin insects or foreign objects l liquid spillage or submersion of goods not designed to sustain such use or duress 2 Where inspections reveal the products are in normal working order including where noise or vibration is consistent with normal product operation 3 Attempted repairs or modifications by unauthorised persons including but not limited to the drilling of hol...

Отзывы: