background image

10

GB

Installation 2300-4900

Before  installation  ensure  the  correct  materials  have 

been prepared and the most suitable pump position has 

been selected. As with all water pumps, the greatest 

flow  efficiency  will  be  created  through  the  shortest 

length  of  pipe/hose  and  with  the  fewest  number  of 

bends. Avoid reducing the size of the plumbing as this 

will greatly reduce flow.

Note: flow is reduced less through 2 x 45° bends than 

through a single 90° bend.

Flexible hose is recommended over rigid pipe as this will 

reduce vibration of the pump. If using rigid plumbing, a 

short piece of flexible hose between the pump and the 

pipes will help to reduce vibration.

If  there  is  a  requirement  to  adjust  the  flow  on  your 

pump, it is essential that in-line taps are used only on 

the  pressure  (outlet)  side  of  the  pump.  Restriction  of 

the suction (inlet) side of the pump can cause the motor 

to overheat causing damage to the pump.

It is recommended that the strainer is used to prevent 

fish  or  large  objects  from  entering  the  motor  unit 

and  damaging  the  impeller.  Ensure  the  pump  is  fully 

submersed to prevent air from entering the pump which 

can  result  in  significant  loss  of  flow  and  potentially 

cause damage to the motor.

If  the  pump  is  being  used  in  a  clean,  animal  free 

environment  the  inlet  elbow  can  be  used. This  gives 

the pump the ability to pick up water from a lower point 

reducing the risk of the pump running dry. NOTE: it is 

always recommended that the pump be fully immersed 

in water to avoid the unit overheating.

If these pumps are being used in salt water, they must 

be checked regularly for buildup of calcium and other 

deposits. 

To maximise the life of your pump, it is recommended 

to clean the pump casing and the impeller every 6-8 

weeks or earlier if flow has decreased significantly.

Prior  to  cleaning,  disconnect  the  pump  from  the 

electrical power supply.

The casing of the pump and the strainer can be cleaned 

with  a  firm  brush.  DO  NOT  USE  DETERGENTS 

AS  THE  USE  OF  THESE  WILL  BE  POTENTIALLY 

LETHAL TO AQUARIUM INHABITANTS. Any objects 

on or around the strainer or inlet should be removed to 

prevent potential blockages in the pump or damage to 

the impeller.

Troubleshooting

LOW WATER FLOW

1.  Check  strainer,  impeller  and  impeller  chamber  for 

calcium buildup or other deposits or blockages.

2. Ensure all taps or flow control valves are fully open.

3. Clean plumbing lines to and from the pump.

NO WATER FLOW

1. Ensure all taps or flow control valves are fully open.

2.  Check  that  maximum  head  height  has  no  been 

exceeded. Consider all bends and horizontal plumbing 

when calculating head height.

3. Check impeller and shaft for damage.

PUMP IS NOISY

1. Ensure suction cups are correctly positioned.

2. Check for blockages on the pump inlet. Restriction of 

inlet can cause vibration.

3. Check for damage to impeller or shaft.

Maintenance

water level

inlet elbow

Содержание Moray Series

Страница 1: ...Moray Aquarium Pumps Inspiring Excellence in Fish Keeping www aquaone com au ...

Страница 2: ...ulseur Spécifications Garantie Belangrijke voorzorgsmaatregelen Vóór eerste gebruik Voorbereiding Over Uw Pomp 360 480 Over Uw Pomp 1300 Over Uw Pomp 2300 3600 4900 Pomp Installeren 360 480 1300 Pomp Installeren 2300 3600 4900 Onderhoud Problemen Oplossen Toegang Tot Het Vleugelrad Specificaties Garantie Important Safeguards Before First Use Preparation Know Your Pump 360 480 Know Your Pump 1300 K...

Страница 3: ... wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully...

Страница 4: ...und and the product has been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Aqua One Spare Parts Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the numb...

Страница 5: ...1 Motor 2 Venturi outlet 3 12mm joiner 4 Duckbill 5 Hang bracket 6 Rubber end cap 7 Impeller 8 Shaft 9 Venturi adjuster and airline 10 Impeller cover lock 11 Internal strainer 12 Uplift adapter 13 Strainer 6 1 2 7 8 3 4 5 9 10 11 12 13 ...

Страница 6: ... Hang bracket 3 Rubber end cap 4 Impeller 5 Ceramic shaft 6 Impeller cover lock 7 Internal strainer 8 Uplift adapter 9 Sponge 10 Strainer 11 Venturi outlet 12 Barbed 19mm hose tail 13 Venturi adjuster and airline 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Страница 7: ...bber end cap 4 Impeller 5 Ceramic shaft 6 Impeller cover 7 Impeller lock 8 Internal strainer 9 Sponge 10 Strainer 11 Barbed 25mm hose tail 3600 4900 12 Threaded reducer 3600 4900 13 Barbed 19mm hose tail 14 Inlet elbow 3600 4900 1 3 4 2 5 6 7 8 9 10 11 12 13 14 ...

Страница 8: ...iner and slide the base plate out towards the impeller 2 Slide the hang mount into the groves at the back of the pump 3 Replace the strainer If being used They are also provided with multiple outlet options 1 Duckbill or multi directional outlet allows the water to be channelled a variety of different directions Good for providing water flow to static areas of the aquarium thus reducing waste buil...

Страница 9: ...ability to pick up water from a lower point reducing the risk of the pump running dry NOTE it is always recommended that the pump be fully immersed in water to avoid the unit overheating If these pumps are being used in salt water they must be checked regularly for buildup of calcium and other deposits To maximise the life of your pump it is recommended to clean the pump casing and the impeller ev...

Страница 10: ... could damage your pump 9 Ensure both rubber end caps are in the correct position If they do not come out when the impeller is removed one should be in the impeller chamber and the other in the impeller cover Failure to position them correctly will result in your pump being damaged 10 Do not force the unit back together as the ceramic shaft may break If it does not reassemble easily check the posi...

Страница 11: ... Moray 4900 Maximum Flow Rate 4800L hr Maximum Head Height 3 6m Power Requirements 220 240V Power Consumption 100W Suitable Cold water Tropical Marine Disposal of used Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This symbol on the product or on its packaging indicates that the product must not be disposed of with no...

Страница 12: ...ermines goods are being used in a manner contrary to the instructions specifications or this Guarantee Aqua One reserves the right to terminate Extended Guarantee for such goods and will provide written notice to the purchaser 3 0 Exclusions and Limitations Where permitted by local law the following exclusions and limitations apply in regard to Guarantee 3 1 Goods claims where fault is due to but ...

Отзывы: