8
The connections of the unit are (please refer to Fig. 4):
1.
Tap water inlet – into the prefilter (1)
2.
Waste water outlet (14) at the flush valve (3)
3. Pure water (permeate) (2)
4. Tap connection
Attach the tap connection to a 3/4" tap (cold water). If necessary, use a reduction piece (not
included in shipment).
3. Start up
Tighten all 10" housings using the supplied wrench. Open membrane housing and insert
membrane.
Fig. 2: Mounting the O-ring of the membrane’s housing
Don’t insert the O-ring of the membrane’s housing into the screw cap but push it onto
the housing.
Tighten the membrane’s housing’s lid with the wrench.
When all connections are tight, you can open the tap water and insert the power plug (220 –
240 V / 50/60 Hz). Check all connections for leaks.
The fittings are sealed with Teflon tape. If they
are leaking, they can be sealed using some Teflon tape. The system flushes automatically both at
the start and during operation. The "Flush" indicator lights up.
Fig. 3: Control unit platinum line plus