Aqua Medic Heat controller duo Скачать руководство пользователя страница 5

 

5

The setting "COOL" can be used when a fan is to be used for cooling at high temperatures instead of a heater. 
But then the cable may not be too strong (max. 10 W per 100 liters), so only a slight flow of the under gravel is 
ensured without significant heating of the water.  

 

Then, you press the "SET" button shortly, 

the 

setpoint appears flashing and can be changed with the arrow keys. 

By  briefly  pressing  the  "SET"  button,  there  will  be  access  to  adjust  the  temperature  difference  between  the 
setpoint and emergency shutdown of the heating cable at an excessively high water temperature. If the setpoint 
plus this set value is reached, the heating cable is switched off until the temperature in the aquarium has dropped 
again below the setpoint.

 

 

By pressing the "SET" button again, you can set the alarm. When reaching the setpoint plus the adjusted value, 
you will hear a beep. 

As soon as the temperature falls below the adjusted value, the unit activates the power 

socket No. 1 and switches the consumer (heating) on. The heating cable is controlled by the timer and power 
socket No. 2.  

 

If you keep pressing the "SET" button for a quite a while, you will reach the timer menu. Here, you can set the 
time also by pressing the "SET" button and the arrow keys. Then, the time how long the heating cable should be 
turned on and switched off has to be adjusted. A mode of 15 minutes each have been proved suitable. Again, the 
value to be changed is selected and then adjusted using the arrow keys by pressing the "SET" button. 
 
By pressing the OK button you can leave the setting menu.

 

 

The heat controller duo has got a rechargeable battery so the programmed data will not be  lost in 
case of power failure. After starting the unit up, it takes about 24 hours until the battery is charged 
and the data remain stored.  
 

For safety reasons, you should control the nominal values, especially after a power failure.

  

 

5.

 

Technical Data

 

 

Display: 

 

 

 

0.1 °C 

Measurement range: 

 

0.0 up to +50.0 °C   

 

 

                            

Resolution:   

 

 

0.1 °C  

Loading capacity of contact: 

1,200 watts at 220 V AC                                                             

Air Humidity: 

 

 

below 80% 

Adjustment range:   

 

16 – 40 °C 

Adjustment accuracy: 

 

+/- 1 °C  

Power requirements: 

 

220 V / 50 Hz   

 

 

 

 

Humidity:                                  

< 85% 

 
6. Warranty conditions  

 
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material 
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by 
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or 
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period, we 
will  repair  the  product  for  free  by  installing  new  or  renewed  parts.  This  warranty  only  covers  material  and 
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper 
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. 

In case of a 

fault with the unit during or after the warranty period, please contact your dealer. All further steps 
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to 
us  via  specialist  dealers  cannot  be  processed.

  AB  Aqua  Medic  is  not  liable  for  consequential  damages 

resulting from the use of any of our products.  
 

AB Aqua Medic GmbH

 

-

 

Gewerbepark 24 - 49143 Bissendorf/Germany 

- Technical changes reserved – 03/2019 

 
 
 
 

 
 
 

Содержание Heat controller duo

Страница 1: ...ire soigneusement les instructions d avant utilisation P 6 7 NL Gebruiksaanwijzing Lees de handleiding voor gebruik zorgvuldig door P 8 9 ES Manual de instrucciones Por favor lea el manual cuidadosame...

Страница 2: ...abeln oder matten vorgesehen Die maximale Schaltleistung liegt bei 1 200 W 3 Inbetriebnahme 220 V Anschluss herstellen Messf hler im Aquarium fest anbringen Sauger oder Elektrodenhalter Nach einigen M...

Страница 3: ...roller duo hat eine aufladbare Batterie damit die programmierten Daten bei Stromausfall nicht verloren gehen Nach Inbetriebnahme dauert es etwa 24 Std bis die Batterie geladen ist und die Daten gespei...

Страница 4: ...trolling heating cables or mats by a timer The maximum output is approx 1 200 watts 3 Installation Connect to 220 V power source Place the temperature sensor into the aquarium and fix it with an Aqua...

Страница 5: ...as got a rechargeable battery so the programmed data will not be lost in case of power failure After starting the unit up it takes about 24 hours until the battery is charged and the data remain store...

Страница 6: ...m est affich e Photo 1 heat controller duo 1 Prise 1 Chauffage 2 Prise 2 Cable chauffant 3 Symbole du mode chauffage 4 Fl ches destin es au changement de param tre 5 Affichage cable chauffant ON OFF M...

Страница 7: ...e les donn es restent stock es Pour plus de s curit vous devriez contr le les valeurs de r f rence en particulier apr s une panne de courant 5 Donn es techniques Affichage 0 1 C Zone de mesure 0 0 50...

Страница 8: ...van een timer De maximale output is ca 1 200 Watt 3 Installatie Verbind het apparaat met een 220 V voedingsbron Plaats de temperatuur sensor in het aquarium en zet het vast met een Aqua Medic electro...

Страница 9: ...een keer uitvalt Na het opstarten van de unit zal het ca 24 uur duren voordat de batterij is opgeladen en alle data behouden blijven Om veiligheidsredenen is het verstandig de eerder ingestelde waarde...

Страница 10: ...ima es de aproximadamente 1 200 Watts 3 Instalaci n Enchufar el aparato a una fuente de corriente de 220 V Introducir la sonda de temperatura en el acuario y fijarla en el soporte de electrodos de Aqu...

Страница 11: ...as 24 horas hasta que la bater a est cargada y la informaci n quede guardada Por razones de seguridad usted deber revisar los valores programados especialmente despu s de un fallo en la energ a 5 Info...

Страница 12: ...12 RUS 1 Aqua Medic heat controller duo 2 2 1 1 200 3 220 1 heat controller duo 1 1 2 2 3 4 5 ON OFF 4 LOC SET 10 LOC SET HEAT 1 3 SET...

Страница 13: ...2 SET SET 15 SET heat controller duo 24 5 0 1 C 0 0 50 0 C 0 1 C 1 200 220 AC 80 16 40 C 1 C 220 50 85 6 AB Aqua Medic GmbH 24 AB Aqua Medic AB Aqua Medic GmbH AB Aqua Medic GmbH Gewerbepark 24 49143...

Отзывы: