- The module is blocked or used up:

  The membrane has to be changed.
  As spare parts all standard 18“- membranes with the model specific capacity can be used.
Only   TFC- membranes made of Polyamide/Polysulfone should be used. We recommend to
use  the   original 

 

TFC-membranes. If you want to use a membrane with a

different   capacity, you have additionally to change the flushing valve.

- The

 r

ejection rate is too low:

  Check the water flow rates (waste water, pure water).
  If the water flow is ok, flush the unit for approx. 60 min, by removing the flow restrictor. If
the   rejection rate increases, go on flushing until the value is acceptable. If the rate does not
improve,   change the membrane.

7. Important Notes

- Connection: 

Connect the reverse osmosis unit only to the cold water supply. Higher

temperatures   increase the pure water production, but at temperatures above 40°C, the
membrane will be   destroyed.

- Stopping the unit: 

If you stop the unit, always close the tap water supply. Put never a valve

into   pure water.  If you run the unit automatically with a solenoid valve, switch the valve
between   prefilter and module. Take care that waste water and pure water can flow away
freely.

- Disconnection of the unit: 

If you want to disconnect the unit for a period longer than 6

weeks,   you should add AQUA MEDIC desinfection liquid into the module housing. If the
unit is then   started again, flush it for 15 min. We recommend flushing also after shorter
periods of stopping.

- Storage:

 The unit has to be stored at temperatures above 0° C. Freezing would destroy the

  membrane.

- Temperature: 

At low temperatures in winter, the permeate production slows down. For the

   calculation of the production rate, see the following table.

8. Warranty

We guarantee 12 months on material defects. Wearing parts, e.g. prefilters as well as damages
caused by use of force and incorrect storage (freezing) or handling are not covered under
warranty.

 

is not liable for consequential damages (e.g. caused by water).

Warranty only by proof of purchase by the original invoice.

- Technical changes reserved -

Appendix:

Table1: Relation between the pure water capacity of AQUA MEDIC     reverse osmosis

membranes and the water pressure before the membrane and the water
temperature. The values are mean values, the spread is  +/- 15%

  .

Содержание Easy Line 90

Страница 1: ...ested by professionals With this unit you can remove the inorganic and organic substances dissolved in your tap water to a percentage of about 95 98 without the addition of chemicals In the aquarium you prevent overfertilisation of the water from the tap The growth rate of diatoms and other microalgaes is reduced Residues of pesticides and other toxic substances do not get into the aquarium Please...

Страница 2: ...tic membrane Polyamide Polysulfon TFC which has the following capacitie Reverse osmosis unit Liter Day Easy Line 90 75 90 l Flow restrictor At this valve the permeat concentrate ratio is adjusted to 1 4 Tap water connection fitting with pressure tube Figure 1 1 sediment filter 2 water inlet 3 activated carbon filter 4 reverse osmose module 5 pure water outlet 6 waste water outlet with flow restric...

Страница 3: ...re water permeate Waste water concentrate 1 2 3 Mounting of the membrane Remove the screw cap from the module housing fig 1 7 Take the membrane from the plastic bag and put it into the menbrane housing Take care to insert the membrane in the right direction with both sealings 1 directed to the water outlet The membrane has to be pushed forward until the 2 sealings are inthe right position at the t...

Страница 4: ...lids and cacti In laboratories and industry everywhere where up to now destilled or deionised water has been used and a conductivity of 20 50 µS cm is accepted 5 Maintenance Prefilter If the tap water is not extremely polluted a yearly replacement of both prefilters will be sufficient If the water is higher polluted the filters have to be changed more often as required If the prefilter is blocked ...

Страница 5: ...cally with a solenoid valve switch the valve between prefilter and module Take care that waste water and pure water can flow away freely Disconnection of the unit If you want to disconnect the unit for a period longer than 6 weeks you should add AQUA MEDIC desinfection liquid into the module housing If the unit is then started again flush it for 15 min We recommend flushing also after shorter peri...

Страница 6: ...ay Type 150 l day 3 bar 5 24 46 79 10 28 55 94 15 33 64 110 20 38 76 130 25 45 88 151 4 bar 5 31 61 105 10 37 73 125 15 44 86 147 20 51 101 173 25 61 118 201 5 bar 5 39 76 131 10 47 91 156 15 55 107 184 20 65 126 216 25 75 147 252 6 bar 5 47 92 157 10 56 109 221 15 66 129 267 20 56 156 267 25 90 177 302 ...

Отзывы: