1. Delivery

The 

reverse osmosis units are compact and highly efficient units. They

consist of the following parts:

- Sediment prefilter, 

10“

 

5 µm pore size,

- Activated carbon prefilter, 10“
- Reverse osmosis module

, with  a first class synthetic membrane (Polyamide/

  Polysulfon, TFC) which has the following capacitie:

Reverse osmosis unit...

Liter/Day

Easy Line 90

  75 – 90 l

Flow restrictor .

 At this valve, the permeat/concentrate ratio is adjusted to 1 : 4.

Tap water connection fitting 

with

 

 pressure tube.

                                                                                                        

 Figure 1

1 sediment filter
2  water inlet
3  activated carbon filter
4  reverse osmose module
5  pure water outlet
6  waste water outlet
    with flow restrictor
7. Cap of module housing

7

Содержание Easy Line 90

Страница 1: ...ested by professionals With this unit you can remove the inorganic and organic substances dissolved in your tap water to a percentage of about 95 98 without the addition of chemicals In the aquarium you prevent overfertilisation of the water from the tap The growth rate of diatoms and other microalgaes is reduced Residues of pesticides and other toxic substances do not get into the aquarium Please...

Страница 2: ...tic membrane Polyamide Polysulfon TFC which has the following capacitie Reverse osmosis unit Liter Day Easy Line 90 75 90 l Flow restrictor At this valve the permeat concentrate ratio is adjusted to 1 4 Tap water connection fitting with pressure tube Figure 1 1 sediment filter 2 water inlet 3 activated carbon filter 4 reverse osmose module 5 pure water outlet 6 waste water outlet with flow restric...

Страница 3: ...re water permeate Waste water concentrate 1 2 3 Mounting of the membrane Remove the screw cap from the module housing fig 1 7 Take the membrane from the plastic bag and put it into the menbrane housing Take care to insert the membrane in the right direction with both sealings 1 directed to the water outlet The membrane has to be pushed forward until the 2 sealings are inthe right position at the t...

Страница 4: ...lids and cacti In laboratories and industry everywhere where up to now destilled or deionised water has been used and a conductivity of 20 50 µS cm is accepted 5 Maintenance Prefilter If the tap water is not extremely polluted a yearly replacement of both prefilters will be sufficient If the water is higher polluted the filters have to be changed more often as required If the prefilter is blocked ...

Страница 5: ...cally with a solenoid valve switch the valve between prefilter and module Take care that waste water and pure water can flow away freely Disconnection of the unit If you want to disconnect the unit for a period longer than 6 weeks you should add AQUA MEDIC desinfection liquid into the module housing If the unit is then started again flush it for 15 min We recommend flushing also after shorter peri...

Страница 6: ...ay Type 150 l day 3 bar 5 24 46 79 10 28 55 94 15 33 64 110 20 38 76 130 25 45 88 151 4 bar 5 31 61 105 10 37 73 125 15 44 86 147 20 51 101 173 25 61 118 201 5 bar 5 39 76 131 10 47 91 156 15 55 107 184 20 65 126 216 25 75 147 252 6 bar 5 47 92 157 10 56 109 221 15 66 129 267 20 56 156 267 25 90 177 302 ...