Then, mount the membrane and connect the tubes. To avoid any failures, follow the instructions
carefully:
Tube fittings:
1. Remove the blue lock ring.
2. Insert the hose to a complete stop into the fitting.
3. Refit the lock ring.
4. Pull the hose back as a test that it is located.
Release the plug connection:
1.
Remove the blue lock ring.
2.
Push the white ring at the fitting. Now, you can remove the tube.
3.
Please don’t forget to refit the lock ring.
The connections of the unit are (please refer to Fig. 1):
Note: Before taking the unit into first operation, rinse the pre-filter and then attach it to
the reverse osmosis module!
1. Attach the tap connection to a 3/4" tap. If necessary, use a reduction piece (not included in
shipment).
2. By using a piece of tube, one puts it from the tap connection into the tap water inlet of the unit
into the pre-filter (1).
3. Connection between pre-filter and reverse osmosis module.
4. Waste water outlet (6) at the flush valve.
5. Pure water (permeat) (5).
Mounting the membrane:
Remove the screw cap of the module housing (Fig. 1, No. 4). Take the membrane out of the plastic
bag and put it into the reverse osmosis module. Take care to insert the membrane in the right
direction (Fig. 2, No. 2) with both sealings (Fig. 2, No. 1) directed to water outlet. The membrane
has to be pushed forward until the 2 sealings are in the right position at the top and the pure water
sealing (Fig. 2, No. 3) is fixed. Before the housing can be closed, mount the O-ring (Fig. 1, No. 9)
on the reverse osmosis module.