![Aqua MAX CF26 series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/aqua-max/cf26-series/cf26-series_owners-manual-and-installation-instructions_2958581041.webp)
INSTALLATION
–
CONTROLLERS
41
KITCHEN CONTROLLER
The Kitchen controller (PN AQ3264104) is to be installed in the kitchen or laundry only. It has a minimum
temperature setting of 37°C and a maximum temperature setting of:
CF26-60 series
60°C
CF26-50 series
48°C
Choose a suitable location for the Kitchen controller, away from water, heat and sunlight.
Kitchen Controller Components
Wiring installation:
1.
Penetrate the wall with a 30-35 mm hole at the controller location.
2.
Install the Kitchen controller cable between the location of the controller and the water heater.
3.
Remove the base plate from the controller.
4.
Draw the cable through the central hole in the base plate.
5.
Fix the base plate to the wall using suitable screws and wall anchors.
Ensure the projections in the base plate are pointing upwards.
6.
Connect the cable to the two terminals on the back of the controller (connections are not polarity
sensitive).
Ensure the connecting screws are seated tightly.
7.
Place the controller over the base plate.
Ensure the projections in the base plate fit into the housings in the controller.
8.
Fix the controller to the base plate at the bottom of the controller, using the controller screw provided.
9.
Proceed to
“Connecting the Controller(s) to the Water Heater”
on page 45.
screw x 2
controller screw
Kitchen controller
base plate