background image

 

37 

CONNECTIONS 

 PLUMBING 

 
All  plumbing  work  must  be  carried  out  by  a  qualified  person  and  in  compliance  with  the  Standard 
AS/NZS 3500.4 and all local codes and regulatory authority requirements. 
 
All  gas  work  must  be  carried  out  by  a  qualified  person  and  in  compliance  with  the  Standard  AS 5601  or 
AS/NZS 5601.1,  as  applicable  under  local  regulations,  and  all  local  codes  and  regulatory  authority 
requirements. 
 

CONNECTION SIZES 

Model 

CF20 series 

 

 

 

Hot water connection 

R¾/20 

 

 

 

Cold water connection 

R¾/20 

 

 

 

Gas inlet 

R¾/20 

 

 

 

 

WATER INLET AND OUTLET 

All  pipe  work  must  be  cleared  of  foreign  matter  before 
connection  and  purged  before  attempting  to  operate  the 
water heater. All olive compression fittings must use brass 
or  copper  olives.  Use  thread  sealing  tape  or  approved 
thread sealant on all fittings. 
 
A full flow gate valve or ball valve must be installed on the 
cold  water  line  or  solar  preheat  water  line  to  the  water 
heater. 

A  non  return  valve  or  stop  tap  must  not  be 

installed.

  An  acceptable  arrangement  is  shown  in  the 

diagram.  Refer  also  to 

“Hot  Water  Delivery”

  on  page 29 

and t

“Mains Water Supply”

 on page 28. 

 
A disconnection union must always be provided at the cold 
water  inlet  and  hot  water  outlet  on  the  water  heater  to 
allow for disconnection of the water heater. 
 
Insulation  used  on  the  cold  and  hot  water  lines  must 
extend up to the cold water inlet and hot water outlet of the 
water heater. 
 

Notes: 

 

It  is  essential  all  pipe  connections  be  correctly  aligned,  otherwise  component  connections  within  the 
water  heater  may  be  strained  and / or  components  themselves  misaligned.  It  is  recommended  also, 
wherever possible, pipe connections be made at the  water heater first and final pipe runs be made in 
soft copper pipe to allow some adjustment for misalignment. 

 

Use  the  spanner  flats  on  the  water  heater  fittings  and  take  care  to  avoid  twisting  the  water  inlet  and 
outlet pipes inside the jacket. 

 

The maximum supply temperature to the water heater when used as an in-series gas booster to a solar 
water heater is 80°C. 

 

HOT

WATER

POWER

CORD

PRESSURE LIMITING VALVE

(not required if water heater

is installed as an inline gas

booster to a solar water heater)

GATE VALVE

OR

BALL VALVE

GAS

COCK

WATER AND GAS CONNECTION DETAIL

COLD OR SOLAR

PREHEAT WATER

GAS

 

 

Gas Water Heater 

Cold (or Solar Preheat) and Hot Water 

and Gas Connection Details 

Содержание CF20 series

Страница 1: ...is water heater must be installed and serviced by a qualified person Please leave this guide with the householder Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater CF20 seri...

Страница 2: ...d or Rheem Australia Pty Ltd Trademark of Aquamax Australia Pty Limited or Rheem Australia Pty Ltd Note Every care has been taken to ensure accuracy in preparation of this publication No liability can...

Страница 3: ...the installer but may be of interest About Your Water Heater 4 Temperature Control 11 Water Supplies 22 Save A Service Call 23 Installation Water Heater 26 Connections Plumbing 37 Connections Electric...

Страница 4: ...up to 75 C with an Aquamax pumped direct solar system during periods of low solar energy gain will boost the water temperature automatically to its preset outlet temperature setting WATER HEATER OPERA...

Страница 5: ...heater has been installed to an existing water heater installation then all controllers must be disconnected and removed If this water heater is installed as part of a solar water heater system the sy...

Страница 6: ...mbustible materials near the water heater Flammable liquids such as petrol newspapers and similar articles must be kept well away from the water heater and the flue terminal Do not use aerosols stain...

Страница 7: ...ts Spray insecticide around the water heater if necessary to rid the area of insects Do not spray the surface or into the air inlet or flue terminal of the water heater Insects encroaching into or nes...

Страница 8: ...r Heater on page 9 TO TURN ON THE WATER HEATER Screw in the drain plugs at the cold water inlet and hot water outlet of the water heater if the water heater has been drained Open all of the hot taps i...

Страница 9: ...freezing then it is necessary to drain the water heater refer to Draining the Water Heater on page 9 Pipe work to and from the water heater must be adequately insulated to prevent freezing The water h...

Страница 10: ...e connections on both the solar storage tank and the in series gas booster VICTORIAN CUSTOMERS Notice to Victorian Customers from the Victorian Plumbing Industry Commission This water heater must be i...

Страница 11: ...ner of the controller Warning Temperature controllers must not be fitted to this water heater CF20 60 model if it is installed as an in series gas booster with a solar water heater because water at a...

Страница 12: ...ll controllers whether they are on or off when hot water is flowing regardless of which controller has priority display panel The current temperature setting is displayed on all controllers whether ho...

Страница 13: ...n to deactivate the controller on off light is off Press and hold the up button Press the on off button whilst the up button is pressed The sound for the controller is deactivated Repeat this procedur...

Страница 14: ...he water heater defaults to the preset outlet temperature setting This may be up to CF20 60 series 70 C CF20 50 series 48 C Refer to How Hot Should The Water Be on page 5 On a building fitted with a t...

Страница 15: ...roll the temperature setting up to a maximum 43 C if there is hot water flowing or 45 C if there is no hot water flowing From the 45 C setting the up button must be pressed once for each increase in t...

Страница 16: ...ority if a Bathroom controller is on Notes on the Kitchen controller The controller cannot be turned on whilst a hot tap is open The Kitchen controller must be on and have priority in order to adjust...

Страница 17: ...tment on page 15 The selected temperature setting will be displayed on all controllers 4 Open the hot tap The in use light will glow on all controllers 5 Close the hot tap The in use light will go out...

Страница 18: ...installed in the hot pipe to the bathroom or up to 60 C if a temperature limiting device is not installed CF20 50 series 48 C Notes on the Bathroom controllers The controller cannot be turned on whil...

Страница 19: ...Press the on off button The on off operating light and the priority light will both glow The previous Bathroom controller temperature setting will be displayed on the temperature display panel 3 Sele...

Страница 20: ...ill change the water volume setting by 10 litres Pressing the up button or down button continuously will scroll the water volume setting Fifteen seconds after the water volume has been selected the wa...

Страница 21: ...ller on page 13 The factory preset water volume is 180 litres If a hot tap is not opened for one hour after the new water volume has been set then the setting will be automatically cancelled The water...

Страница 22: ...ation should be sought from the supplier or it should be tested to ensure the water supply meets the requirements given in these guidelines for the Aquamax warranty to apply SATURATION INDEX The satur...

Страница 23: ...of the house Try lighting another gas appliance Has the gas line been purged of air after installation Refer to your plumber WATER IS TOO HOT OR NOT HOT ENOUGH Does the controller you are using have...

Страница 24: ...s permanent or clean the collector glass Ensure the glass on your solar collectors is free of dust salt spray or any other matter which may reduce the effectiveness of the solar collectors If the coll...

Страница 25: ...rror code appears Close the hot tap turn off the controller s and switch off the electrical supply to the water heater Check the gas isolation valve at the gas inlet to the water heater is fully open...

Страница 26: ...elating to the function and operation of the solar water heater refer to the Owner s Guide and Installation Instructions supplied with the solar water heater Note The CF20 50 model water heaters are m...

Страница 27: ...least 300 mm between the top of the flue terminal and the eaves At least 300 mm between the flue terminal and the edge of any opening into the building such as an openable door or window measured hor...

Страница 28: ...the water heater must be insulated with suitable thickness insulation if freezing conditions are likely to occur The insulation must be fitted to the underside of the water heater and be weatherproof...

Страница 29: ...et and the cold water inlet of no less than 15 Refer to the specifications of the temperature limiting device Where a temperature limiting device is installed adjacent to the water heater the cold wat...

Страница 30: ...ure limiting device prior to an open circuit direct system Due to the higher water temperatures generated under certain conditions in the solar collectors of an open circuit direct solar water heater...

Страница 31: ...ed water from a temperature limiting device cannot be circulated Where a circulated hot water flow and return system is required in a building a temperature limiting device can only be installed on a...

Страница 32: ...water heater and the pipe work between the solar storage tank if one is installed and the in series gas booster must be insulated in accordance with the requirements of AS NZS 3500 4 The insulation mu...

Страница 33: ...lers Only CF20 50 series CF20 60 series No Controllers CF20 50 series Notes Temperature Limiting Devices refer to Hot Water Delivery on page 29 Factory preset outlet temperature setting is CF20 60 ser...

Страница 34: ...ural 70 C Recovery 25 C rise litres min 20 CF20 LP 50 propane 48 C Mass Empty kg 18 CF20 LP 60 propane 70 C Gas Details Hourly Gas Consumption MJ Min Gas Pressure kPa Test Point Gas Pressure kPa Max G...

Страница 35: ...INSTALLATION WATER HEATER 35 DIMENSIONS CONTROLLERS Kitchen Controller Bathroom Controller...

Страница 36: ...INSTALLATION WATER HEATER 36 TYPICAL INSTALLATION OUTDOOR LOCATION TYPICAL INSTALLATION ELECTRONIC INSTANTANEOUS GAS WATER HEATER...

Страница 37: ...29 and to Mains Water Supply on page 28 A disconnection union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater In...

Страница 38: ...d up to the connections on both the solar storage tank and the in series gas booster A full flow isolation valve must be installed on the water line to the in series gas booster GAS INLET The gas conn...

Страница 39: ...ing water heater installation then all controllers must be disconnected and removed The water heater is supplied with a 1 8 metre lead and plug and requires a weatherproof 240 V 50 Hz general purpose...

Страница 40: ...m1 controller is installed An additional Kitchen controller cable or Bathroom controller cable can be used if an extension of the cable length is required It will be necessary to cut an opposite end o...

Страница 41: ...er 3 Remove the base plate from the controller 4 Draw the cable through the central hole in the base plate 5 Fix the base plate to the wall using suitable screws and wall anchors Ensure the projection...

Страница 42: ...g in the thin section in the underside of the controller to accommodate the cable as shown in the diagram prior to Step 6 Kitchen Controller Installation Exposed Cable controller cable screws terminal...

Страница 43: ...e setting of CF20 60 series 50 C CF20 50 series 48 C The method of installation for the Bathroom1 and Bathroom2 controllers is identical Choose a suitable location for each Bathroom controller away fr...

Страница 44: ...al hole in the base plate 7 Fix the base plate to the wall using suitable screws and wall anchors Ensure the projections in the base plate are pointing upwards 8 Plug the controller wire into the Bath...

Страница 45: ...e connections are non polarised Up to three cable lugs one from each type of controller can be connected to each remote controller terminal Warning Do not confuse the remote controller terminals with...

Страница 46: ...s not adjustable To complete the installation it is necessary to check the gas supply pressure at the inlet to the water heater refer to Gas Inlet Pressure on page 46 the minimum test point pressure a...

Страница 47: ...off button 7 Open a hot tap fully and ensure the burners are fully ignited It may be necessary to open a second tap 8 Turn on all other gas burning appliances in the house which are on the same gas s...

Страница 48: ...um test point gas pressure Refer to the rating label on the water heater for the minimum test point gas pressure 1 Close any hot taps and ensure the burners are not operating 2 Turn off the controller...

Страница 49: ...and observe the reading on the manometer Note While the MIN button is pressed the gas pressure will at first increase then decrease cycling between an upper gas pressure limit 39 on the controller di...

Страница 50: ...ressing the on off button Switch off the electrical supply at the power outlet to the water heater Disconnect the controller cable from the remote terminal screws Reconnect the cables from the control...

Страница 51: ...d as an in series booster for a solar water heater it can satisfy this AS 3498 requirement provided it is energised the booster preset outlet temperature setting is 70 C and that a remote temperature...

Страница 52: ...he jacket 3 Gently disengage the front panel and pull forward to remove from the water heater 4 Switch on the electrical supply at the power outlet to the water heater 5 Switch DIP SWITCHES 3 and 4 to...

Страница 53: ...et to the water heater Close the cold water isolation valve at the inlet to the water heater Drain the water heater if there is a risk of freezing conditions occurring Refer to Draining The Water Heat...

Страница 54: ...y the shower outlet Unscrew the two drain plugs one each at the cold water inlet and hot water outlet on the underside of the water heater Water will drain from the water heater When water stops flowi...

Страница 55: ...r ready access the cost of that access including the cost of additional materials handling and or safety equipment shall be the owner s responsibility In other words the cost of dismantling or removin...

Страница 56: ...or rating labels b Is not installed in Australia 5 HOW TO MAKE A CLAIM UNDER THIS WARRANTY 5 1 If you wish to make a claim under this warranty you need to a Contact Aquamax on 1800 676 000 and provid...