11. Turn the adjustment handwheel anti-clockwise to the
end. Hold the lever down against the insert and push
the insert assembly out of the casing.
12. Remove the spacer (129652) and the o-ring (124706).
13. Remove the red Venturi baffle (129644).
14. Screw the handwheel half turn then the key must fall
on the table.
If the key remains, remove it , using the o-ring
extractor.