![Aqua Lung LEGEND LUX Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/aqua-lung/legend-lux/legend-lux_service-manual_2958545010.webp)
Legend LX LUX second stage service manual
RE-ASSEMBLY PROCEDURE
Service manual Legend LX – LUX second stage
Rev. 12/2011
10
1. If the exhaust valve has been removed, pass the valve
tail through the hole in the casing from the outside and
pull gently until the notch is inside the casing. If it is a
new valve cut off any excess tail leaving about 5mm.
2. Fit a new lubricated o-ring (AP2041) into the shuttle
valve groove and insert a new valve seat (129638) into
the shuttle valve.
NOTE: Make sure the seat is properly
pressed against the shuttle valve. If
necessary, perform a rotation of your thumb
pressing the seat.
3. Insert the spring into the balancing chamber. Carefully
guide the shuttle valve tail into the spring and insert it into
the balancing chamber.
4.
If the lever has been disassembled, replace it taking
care to put it on the same side as the indent on the
insert. The lever must be set like it is shown on the
picture.
5. Fit a new lubricated o-ring (AP1438) on the insert
(129626), left side ( or thread insert side ) on the
shoulder
NOTE: Using your brush, grease the tail of
the shuttle valve with Christolube MCG111