Glacia Second Stage Service & Repair Manual
© 2000 Aqua Lung America, Inc.
16. Separate the spring (9) from the poppet. Using the brass o-ring tool or a safety pin, pierce the center of
low-pressure seat (7) and remove it from the poppet.
17. With the front of the second-stage housing facing you and the mouthpiece opening flat against the
work surface, use a small screwdriver to rotate the vane c-clip so the open end is facing you. While
holding the box bottom secure, place the tines of the Micra Pre-adjustment Tool (P/N 100168) squarely
against the ends of the circlip (26) as shown in Fig. 8. Gently press the circlip straight off the vane
adjustment switch (27), and set it aside.
Fig. 8 – V.A.S. Circlip Removal
18. Pull the vane adjustment switch straight up and out of the outlet boss of the box bottom. Remove and
discard the o-ring (28), and set the switch aside.
This concludes the disassembly of the Glacia second stage. Refer directly to Procedure A and
Table A, titled
"Cleaning & Lubrication", before proceeding to the Reassembly Procedures.