3
Remove the conical filter (36) and o-ring (10) from the yoke
clamp connector (32). Use a 6mm hex key to remove the filter
guard (31) from the clamp connector. Discard filter, guard and o-ring.
1
Secure the vise mounting tool and first stage into a bench
vise. Use a 6mm hex key to loosen the handwheel connector
(34). Lift off the handwheel connector, handwheel (35) and
distance piece (6).
2
Push the conical filter
(36) and o-ring (10) out
of the handwheel connector
(34) using the end of the seat
installation/extraction tool (PN
109437) and discard.
3
Remove the face o-ring (29) from the handwheel connector
(34) and discard.
This Concludes the Disassembly of the
DST First Stage.
DIN Disassembly
Before starting reassembly, perform parts
cleaning and lubrication in accordance with
Procedure A: Cleaning and Lubricating on
page (27).
DST First Stage Assembly
1
Install the valve lifter (4) into the body (5). Seat the diaphragm
(3) evenly into the body on top of the valve lifter.
2
Place the spring carrier (2) on top of the diaphragm (3),
followed by the spring (1).
3
Install the spring adjuster (22) into the diaphragm clamp
(21) far enough for a couple of threads to catch. Install the
vise mounting tool into the HP port and secure in a bench vise.
Thread the diaphragm clamp to the body (5) and tighten down
using the Apeks spanner wrench (AT30) until you get metal to
metal contact.
REASSEMBLY PROCEDURES
TX50 Technical Manual
8
Содержание APEKS TX 50
Страница 1: ...APEKS TX 50 Regulator TECHNICAL MANUAL REV 05 13 ...
Страница 3: ...Change No Date Title or description Change made by CHANGE RECORD 3 ...
Страница 30: ...Maintenance Notes TX50 Technical Manual 30 ...
Страница 31: ...Maintenance Notes 31 ...