NOTE:
The following steps must be performed while the first
stage is still pressurized.
6
Let the first stage stand
pressurized for several
minutes. Check that the MP,
remains stable. If the MP rises
more than 5 psi (0.3 bar), it
indicates a leak. If the MP is
stable, close the valve, purge
the line, and pressurize once
again to perform the final
check and assembly.
FIRST STAGE FINAL ASSEMBLY
1
With the first stage still
pressurized, insert the
hydrostatic transmitter (23) into
the dry chamber and through
the adjustment screw (22).
2
Install a new hydrostatic
diaphragm (25) into the
enviromental end cap (26).
3
Thread the end cap (26) onto the dry chamber until hand tight.
Using the pin spanner (PN AT30), tighten the end cap until snug.
4
With the end cap in place,
recheck the MP to confirm
there has been no change.
5
Close the cylinder valve and depressurize the regulator.
Remove the test gauge and reinstall the port plug.
THIS CONCLUDES ASSEMBLY OF THE
DST FIRST STAGE
TX50 Technical Manual
12
Содержание APEKS TX 50
Страница 1: ...APEKS TX 50 Regulator TECHNICAL MANUAL REV 05 13 ...
Страница 3: ...Change No Date Title or description Change made by CHANGE RECORD 3 ...
Страница 30: ...Maintenance Notes TX50 Technical Manual 30 ...
Страница 31: ...Maintenance Notes 31 ...