background image

Copyright© 2016 Aqua Logic, Inc.   Effective date of 1/2016  

 

 

 

 

 

 

Specifications 

Aqua Logic Delta Star Chiller features: 
 

 

Titanium heat exchanger for use in fresh and saltwater applications. 

 

Included Protective cover 

 

Made in the USA 

 

Limited 1-year warranty 

 

 

 

Model 

HP 

BTU 

Volts  AMP  Refrigerant  Evaporator 

Flow 

(gpm) 

Condenser 

*Flow 

(gpm) 

Evaporator      

I/O 

FIPT 

*

 Condenser      

I/O 

FIPT 

Dimensions 

(LxWxH 

inches) 

Weight 

(lbs) 

DS-4-WCMD 

1/3  4050 

115 

7.2 

R-134A 

10-20 

3-5 

¾” 

¾” 

23 x 14 x 14 

75 

DS-5-WCMD 

1/2  6000 

115 

9.5 

R-134A 

12-25 

3-5 

1½” 

1½” / ¾” 

24 x 16 x 16 

125 

DS-6-WCMD 

1/2  6000 

230 

4.8 

R-134A 

12-25 

3-5 

1½” 

1½” / ¾” 

24 x 16 x 16 

125 

DS-7-WCMD 

3/4  9500 

115  13.0 

R-134A 

15-30 

5-10 

1½” 

1½” / ¾” 

25 x 21 x 15 

155 

DS-8-WCMD 

3/4  9500 

230 

7.0 

R-134A 

15-30 

5-10 

1½” 

1½” / ¾” 

25 x 21 x 15 

155 

DS-9-WCMD 

1  12000  230 

7.2 

R-134A 

20-35 

5-10 

1½” 

1½” / ¾” 

27 x 24 x 15 

165 

DS-10-WCMD 

1.5  21000  230  10.5 

R-417A 

25-40 

10-15 

1½” 

1½” / ¾” 

31 x 26 x 19 

225 

 

The condenser seawater flow rate is based on 55-60 °F entering water temperature. The condenser 

head pressure is maintained by metering the water flow via gate valve. 

 
 
 
 
 
 

 

 

 

Содержание DS-10-WCMD

Страница 1: ...__________ Installation and Maintenance Manual For Delta Star Water cooled Marine Duty In Line Water Chillers Models DS 4 WCMD thru DS 10 WCMD DS 9 WCMD shown Use Quick Install page for easy setup Aqu...

Страница 2: ...components to assemble equipment that will operate faithfully for years You can call us or visit us on the web for technical assistance before and after the sale We are committed to making sure that y...

Страница 3: ...repair if necessary Be sure that the water flow through your Aqua Logic Chiller goes into the water inlet bottom and out the top to prevent potential damage see illustration If you use flexible hose t...

Страница 4: ...er fittings for leaks Apply electrical power to the chiller Adjust the controller to the desired water temperature See Operation and Programming Important Regulate condenser water until pressure on th...

Страница 5: ...ss the differential The LCD will display the current differential and the DIF enunciator will be blinking on and off to indicate that the control is in the differential mode Then press either up key t...

Страница 6: ...a temperature controller on the lights to shut them off and to sound off an alarm if water temperature rises more than 5 F above the Chiller set point Keep a spare pump on hand in case your primary p...

Страница 7: ...anics slime Remove power from the Chiller Wear protective eyewear clothing and gloves Mix a solution of 1 part unscented chlorine bleach to 4 parts water For a Delta Star Chiller use a small pump pail...

Страница 8: ...4050 115 7 2 R 134A 10 20 3 5 23 x 14 x 14 75 DS 5 WCMD 1 2 6000 115 9 5 R 134A 12 25 3 5 1 1 24 x 16 x 16 125 DS 6 WCMD 1 2 6000 230 4 8 R 134A 12 25 3 5 1 1 24 x 16 x 16 125 DS 7 WCMD 3 4 9500 115 1...

Страница 9: ...or maintenance by user or their agent Damage caused due to misapplication of product Damage caused by corrosion abuse accident alteration or improper use Damage caused by flood fire earthquake tornado...