15
to start forced defrosting.
(Remarks: the interval between manual defrosting should be more than 35 minutes.)
Operation and end way of Automatic and Manual defrosting is same.
i.
Advanced applications (Professional operation)
1)
Running Status Checking
Press “
” for 5 seconds to enter running status checking. During this time, the display will show the
status symbol “C0” and its corresponding value. Change status through “
” and “
” to check
corresponding value. Press “
” to quit “Running Status Checking”.
Running status checking table:
Symbol
Content
Unit
C0
Inlet water temp
℃
C1
Outlet water temp
℃
C2
Ambient temp
℃
C3
Exhaust gas temp
℃
C4
Evaporator coil pipe temp
℃
C5
Return gas temp
℃
C6
Cooling coil pipe temp
℃
C9
Cooling plate temp
℃
C10
EEV opening angle
P
C11
DC motor fan speed
r/min