9
1)
The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation
must be solid and fastened; the bracket must be strong enough and antirust treated;
2)
Please don’t stack substances that will block air flow near inlet or outlet area, and there is no barrier
within 50cm behind the machine, or it will affect the efficiency of the heat pump and even stop the
machine;
3)
The machine needs an appended pump (Supplied by the user). The recommended pump specification-
flux: refer to Technical Parameter, Max lift ≥10m;
4)
When the machine is running, there will be condensation water discharged from the bottom, please pay
attention to it. Please hold the drainage nozzle (accessory) into the hole and clip it well, and then
connect a pipe to drain the condensation water out.
b. Water pipe connection
The inlet and outlet water unions can’t stand the weight of soft pipes. The heat pump must be connected
by hard pipes!
2.
Warning
a.
Connect to appropriate power supply, the voltage should comply with the rated voltage of the products.
b.
Earth the machine well.
c.
Wiring must be handled by a professional technician according to the circuit diagram.
d.
Set leakage protector according to the local code for wiring (leakage operating current ≤ 30mA).
e.
The layout of power cable and signal cable should be orderly and not affecting each other; the cross-sectional
area of the cables can be appropriately enlarged according to the environmental conditions (such as ambient
temperature, direct sunlight, rainfall, network voltage, cable length)
Содержание MR. PERFECT SC964
Страница 1: ...MR PERFECT INVERTER ZWEMBAD WARMTEPOMP Handleiding...
Страница 31: ...MR PERFECT INVERTER SCHWIMMBADW RMEPUMPE BENUTZERHANDBUCH...
Страница 63: ...Pompe chaleur pour piscine InverPad MR PERFECT Pompe chaleur Inverter pour piscine...
Страница 86: ...22 Power Supply 230V 50Hz Earthing Contactor...
Страница 87: ...23...
Страница 95: ...1 MR PERFECT INVERPAD TURBO POOL HEAT PUMP USER MANUAL...
Страница 108: ...12 d Power on Heating mode Cooling mode Auto mode Running speed percentage Wi Fi connection Inlet Outlet...
Страница 121: ...25 Please set family name and choose location of device Create Family b Register through third party application...
Страница 126: ......
Страница 127: ......
Страница 128: ...AQ20CX R32 BC3F V22...