(A) INTRODUCTION

(B) SAFETY GUIDELINES

Aqua Flo AQUV UV systems make water safe to drink by instantly destroying pathogenic 
bacteria (such as coliforms, E. coli, viruses etc.). These systems utilize the proven 
disinfection properties of ultraviolet light (UV) emitted at 254 nm wavelength. UV 
systems are used by many municipalities in North America and around the world as a 
primary disinfectant as it is a natural, non-chemical, environmentally safe technique 
that does not form any harmful disinfection by-products.
 

HOW THE AQUA FLO AQUV UV WATER DISINFECTION SYSTEM WORKS

Your Aqua Flo AQUV UV system consists of a low-pressure UV lamp enclosed in a 
transparent quartz dome, housed in a stainless steel disinfection chamber. As untreated 
water enters the chamber from one end, pathogenic microorganisms in the water are 
exposed to and instantly destroyed by ultraviolet light emitted by a specially engineered 
UV lamp. Treated water flows out of the chamber and is ready for consumption.  
See 

Fig. 1.

Fig. 1.

—

  Lamp contains mercury (Hg).

—

  Dispose or recycle in accordance with applicable laws.

—

  For information on safe handling procedures and safe disposal and recycling, consult :

Contains mercury

Hg

Diverting Mercury 

Management of  

Lamps Containing  

Mercury:

Indicates a hazardous situation which, if not avoided, will result in death or serious injury  

and/or property loss or damage.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury and/

or property loss or damage.

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury 

and/or property loss or damage.

Indicates important information, that if not followed, may result in damage to the equipment.

This is the safety alert symbol. When you see this symbol, look for one of the following signal words:

         

DANGER

         

WARNING

         

CAUTION

NOTICE

Содержание AQUV-12

Страница 1: ...n only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local plumbing codes 3 Test the water periodically to verify that the syste...

Страница 2: ......

Страница 3: ...rganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy Tested and Certified by IAPMO R T to NSF ANSI 61 for material and...

Страница 4: ...roorganisms in the water are exposed to and instantly destroyed by ultraviolet light emitted by a specially engineered UV lamp Treated water flows out of the chamber and is ready for consumption See F...

Страница 5: ...the power outlet by holding the plug Never pull the cord To comply with the National Electrical Code and to provide additional protection from the risk of electric shock this system should only be co...

Страница 6: ...supply of 110V AC It is strongly recommended to have a dedicated electrical circuit for the UV system A CSA or equivalent certified surge protector must be installed to protect the ballast from elect...

Страница 7: ...t between well pump and pressure tank If you have other water filters conditioner installed such as softener iron filter etc the UV system should always be installed as the last step of treatment befo...

Страница 8: ...ppropriate socket wrench 4 Mount the ballast on the wall slightly above the chamber with ballast mounting screws see Fig 3 5 Install new plumbing using Fig 3 as reference of how the final installation...

Страница 9: ...ve and valves before and after UV system Check for leaks Do not proceed to next step until leaks are fixed 12 From the top of the gland nut drop the lamp spring into the quartz dome 13 Holding the top...

Страница 10: ...he faucet off Repeat the procedure for all hot and cold outlets in the house Add more bleach as required Run hot faucets longer to allow the chlorine to come through the hot water tank 4 Leave the ble...

Страница 11: ...rformance that ensures the safety of your drinking water Using non Aqua Flo AQUV UV lamps can not only compromise the system performance but also voids your product warranty electrical and CSA certifi...

Страница 12: ...gland nut 8 A dome O ring thicker and gland nut O ring thinner are included with the replacement lamp Slide gland nut O ring into the internal groove of the gland nut 9 Follow instructions 7 to 15 in...

Страница 13: ...36 104 F ShippingWeight 9lb 4kg 10lb 4 5kg 13lb 5 9kg Replacement Parts System AQUV 8 AQUV 12 AQUV 20 Item 40030101 40030102 40030103 Lamp 89112 89113 89114 QuartzDome 36003037 36003038 36003039 Contr...

Страница 14: ......

Страница 15: ......

Страница 16: ...merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not permitted by law those expres...

Отзывы: