Aqua Flo AQUV-12 Скачать руководство пользователя страница 12

12

How to replace the UV Lamp and clean Quartz Dome:

1.

   Unplug UV unit from electrical outlet and turn off supply valve before the unit. Open a faucet to depressurize the UV system and turn off the   

 

valve at the UV outlet to isolate UV unit. CAUTION: The lamp end can be very hot. Wait several minutes for the lamp to cool down.

2.

   Unscrew the ground nut and remove the ground wire (green wire with yellow stripes).

3.

   Loosen the screw on the lamp connector cover and remove cover from the gland nut.

4.

   Carefully slide UV lamp slightly out of chamber and hold the lamp end with one hand. Gently pull off the connector with your other hand to   

 

disconnect the lamp completely. Slowly remove lamp from the disinfection chamber completely.

5.

   Remove the quartz dome by loosening the gland nut and carefully extracting from the unit. Remove dome absolutely vertically from its   

 

position until the other end comes out. CAUTION: If you bend the dome mid-way, it can break easily and pieces of quartz can fall into the UV   

 

chamber.  Do not lose the spring.

6.

   Remove & discard used dome O-ring. Clean dome gently with a vinegar solution or a household scale-removal product. 

Do not use abrasive   

 pads

. A soft cloth or paper towel is recommended.

7.

   Using a small pointed tool carefully take the gland-nut O-ring out of the    

 

gland nut. Take care not to scratch the gland nut.

8.

   A dome O-ring (thicker) and gland nut O-ring (thinner) are included

 

with the replacement lamp. Slide gland nut O-ring into the internal groove  

 

of the gland nut.

9.

   Follow instructions 7 to 15 in previous section “Installing the UV Unit”.  

 

Do not plug in ballast yet.

10.

 

Depress timer button while reconnecting ballast

 to electrical outlet   

 

and keep the button depressed until the ballast emits a solid three-second  

 

beep. This will re-set the lamp-change-timer to zero and the 3-second beep  

 

will confirm that the re-set was successful.

Winterizing Your System:

To winterize the system, unplug the unit first. Drain the pre-filter by removing 

the sump and dump the water, then drain the UV chamber of all water.

PROBLEM

PROBABLE CAUSE

SOLUTION

Leak at gland nut

Gland nut is loose or O-ring defective

Hand-tighten gland nut & replace O-ring(s)

Condensation outside the UV chamber

High humidity in the environment

This is normal if humid conditions exist. 

Install dehumidifier to protect ballast. Protect 

flooring below UV

Hot water coming out of taps/faucets

Water inside UV unit becomes hot after long 

periods of non-use. You may have oversized 

the unit for the home

To prevent scalding, before using water after 

periods of non-use such as overnight, flush 

water for about 2 minutes. Install a temper-

ature controlled purge valve on the UV outlet

UV lamp ends seem burnt after  

some time

This is normal

As long as the UV lamp lights, a little burn 

mark at the ends is normal and there is no 

need to replace the UV lamp

(H) TROUBLESHOOTING

Содержание AQUV-12

Страница 1: ...n only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local plumbing codes 3 Test the water periodically to verify that the syste...

Страница 2: ......

Страница 3: ...rganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy Tested and Certified by IAPMO R T to NSF ANSI 61 for material and...

Страница 4: ...roorganisms in the water are exposed to and instantly destroyed by ultraviolet light emitted by a specially engineered UV lamp Treated water flows out of the chamber and is ready for consumption See F...

Страница 5: ...the power outlet by holding the plug Never pull the cord To comply with the National Electrical Code and to provide additional protection from the risk of electric shock this system should only be co...

Страница 6: ...supply of 110V AC It is strongly recommended to have a dedicated electrical circuit for the UV system A CSA or equivalent certified surge protector must be installed to protect the ballast from elect...

Страница 7: ...t between well pump and pressure tank If you have other water filters conditioner installed such as softener iron filter etc the UV system should always be installed as the last step of treatment befo...

Страница 8: ...ppropriate socket wrench 4 Mount the ballast on the wall slightly above the chamber with ballast mounting screws see Fig 3 5 Install new plumbing using Fig 3 as reference of how the final installation...

Страница 9: ...ve and valves before and after UV system Check for leaks Do not proceed to next step until leaks are fixed 12 From the top of the gland nut drop the lamp spring into the quartz dome 13 Holding the top...

Страница 10: ...he faucet off Repeat the procedure for all hot and cold outlets in the house Add more bleach as required Run hot faucets longer to allow the chlorine to come through the hot water tank 4 Leave the ble...

Страница 11: ...rformance that ensures the safety of your drinking water Using non Aqua Flo AQUV UV lamps can not only compromise the system performance but also voids your product warranty electrical and CSA certifi...