UNPACKING THE WATER FOUNTAIN

1. 

After unpacking the water fountain, wipe with a soft cloth. Check the unit for evidence of rough handling.

2. 

Place the machine on a hard, flat surface. Make certain the unit is level. The unit should not be close to 

sources of heat, otherwise performance may be affected.

3. 

It is best to place the water fountain in an area with good air circulation. Make sure there is at least 75 mm 
of space between the back of the fountain and the wall.

INSTALLATION

Mounting unit:

1. 

Ensure the wall is clean, even and flat. Install the wall mounted the panel on 

the wall using a screw or other reliable wall-mounting components.

2. 

Ensure the wall mounted panel is safely and firmly mounted on the wall.

3. 

Connect the back of the unit to the wall mounted panel. Please ensure 
the weight of the WM water cooler is applied evenly on the wall mounted 
component panel.

4. 

Ensure the installation is strong and stable. Ensure the connection between 
the wall, wall-mounted component and water cooler can be used for long 
term. Aqua Cooler recommends maintenance inspection should be made 
at 3-month intervals.

Connecting to mains water supply:

The installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2. Pipe jointing is a trade skill and 

Aqua Cooler recommends this process is performed by qualified personnel only.

1. 

Ensure proper ventilation by allowing 75 mm clearance on each side of the fountain.

2. 

Minimum water pressure is 100 kPa and maximum is 700 kPa.

3. 

Install a 40 mm waste trap onto the waste outlet on the rear of the fountain - not supplied.

4. 

Water in connection is secured via a 

1/2

” kinko nut and olive into the stainless-steel connection on the 

rear of the unit. It is recommended that a 

1/2

” shut off valve is installed at this point for ease of future 

maintenance.

5. 

Turn on water supply and hold down bubbler to purge the system of air until a steady stream of water 
comes from the tap.

6. 

For models equipped with a glass filler, please assemble the glass filler by placing the neck onto the white 

tubing pre-installed on the top of the lid.

7. 

The bubbler needs to be adjusted for the correct water flow in relation to the local water pressure. On the 
side of the bubbler is an inner and an outer screw. Once you have established water flow, adjust the inner 

screw until the stream is in the center of the stainless-steel top.

8. 

Check all connections for water leaks.

9. 

Flush fresh mains water through the unit for five minutes to ensure any residual water from testing is 

cleared.

10.  Plug the fountain into the building electrical supply. The unit will start automatically.

Figure Step 1

Figure Step 3

Содержание WM4F

Страница 1: ...Your Partner in Cool Usage and Care Manual Models WM4F WM4SS WM5 WM5SS WM SERIES ...

Страница 2: ...ympathetic The refrigerant flow is controlled by a capillary tube which has no moving parts WM4 WM5 R134a 125g Water Flow Controls The bubbler is rated to supply 1 7 L m at mains water pressure of between 140 and 700 kPa Water Connections Water Inlet 1 2 Male B S P Water Outlet 40mm Female P V C Socket Thermostat Control The thermostat is factory set Electrical 220 240 V 50 60 Hz Weight Packed WM4...

Страница 3: ...erson must replace it in order to avoid hazard 14 This water fountain must be positioned so the plug is accessible 15 Disconnect the plug from the outlet when not in use 16 Remove power plug or disconnect from main power source before servicing the appliance 17 Warranty will be voided if installation is not carried out as detailed in this instruction manual 18 The compressor motor is equipped with...

Страница 4: ...nd AS NZS 3500 2 Pipe jointing is a trade skill and Aqua Cooler recommends this process is performed by qualified personnel only 1 Ensure proper ventilation by allowing 75 mm clearance on each side of the fountain 2 Minimum water pressure is 100 kPa and maximum is 700 kPa 3 Install a 40 mm waste trap onto the waste outlet on the rear of the fountain not supplied 4 Water in connection is secured vi...

Страница 5: ...t cement is applied in full even coats to all applicable surfaces 5 Follow the direction line in figure 1 to connect the PVC pipe to the full depth of the socket and hold the bond joint in position for at least 30 seconds 6 Do not disturb for 5 minutes and allow 24 hours curing before testing See Figure 2 Aqua Cooler suggests using PVC priming fluid to prime PVC pipe prior to application of PCB pi...

Страница 6: ...l should be used Aqua Cooler recommends the water fountain is cleaned every month ensuring there is no blockage in the condenser or in the back of the unit Please remove all potentially harmful factors to prevent any scratch or damage to the unit If customers require the unit s spare parts information please contact the Aqua Cooler Service Department for further assistance The direct line is locat...

Страница 7: ...7 MARKS Spec No WMTS 105 2016 SAI GLOBAL WMK26317 Lic No The appliance is comply with applicable ACMA regulatory arrangements Regulatory Compliance Mark and WaterMark WMTS 105 2016 ...

Страница 8: ...8 Your Partner in Cool EXPLODED DIAGRAM ...

Страница 9: ...8 Cold tank assembly SPM8 9 Evaporator SPM9 10 Cold thermostat SPM10 11 Condenser SPM11 12 Power cord SPM12 13 Rubber feet SPM13 14 Compressor SPM14 Description Code 15 Pressure reduce SPM15 16 Motor SPM16 17 Condenser cover SPM17 18 Fan blade SPM18 19 Condenser bracket SPM19 20 Condenser SPM20 21 Rear panel SPWM21 22 Frame SPWM22 23 Front panel SPWM23 24 Mat SPWM24 25 Plug SPWM25 26 Dryer SPWM26 ...

Страница 10: ...ssure is higher than 700 kPa and a pressure limiting valve is not installed 4 Where the unit is not installed as per installation instructions found within the supplied user manual 5 The warranty does not cover defects occasioned by misuse alterations accident or where the water cooler has been stored on its side FOR ANY CLAIM UNDER THIS WARRANTY PLEASE CONTACT AQUA COOLER PTY LTD PHONE 61 02 9721...

Страница 11: ...Your Partner in Cool ...

Страница 12: ...Your Partner in Cool Phone Numbers Sales 1300 278 226 Service 1800 278 226 Address U14 2 12 Knobel Court Shailer Park QLD 4128 Internet www aquacooler com au info aquacooler com au ...

Отзывы: