Aqua Cooler WM4F Скачать руководство пользователя страница 3

3

IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should be followed to reduce the risk of fire, electric 

shock and injury to persons or property. Read all instructions before using any appliance.

1. 

Keep combustible material such as furniture, 
bedding, pillows, clothes and/or papers away 
from the back of the unit.

2. 

Do not operate this, or any other appliance, with 
a damaged power cord. 

3. 

No other appliance should be plugged into 
the same outlet. Be sure that the plug is fully 
inserted into the outlet.

4. 

Do not run the power cord over carpeting or 
other heat insulators. 

5. 

Do not cover the power cord. 

6. 

Keep the power cord away from high traffic 

areas.

7. 

Do not submerge the power cord in water.

8. 

We do not recommend the use of extension 
cords as they may overheat and increase the 

risk of fire.

9. 

Exercise caution and use reasonable supervision 
when the appliance is used by or near children.

10.  Make sure that there is at least 75 mm of space 

between the back of unit and wall. Keep a 
minimum of 75 mm on each side of unit free.

11.  Do not use this product to dispense anything 

other than water.

12.  This appliance must be placed on an even and 

flat surface.

13.  If the supply cord is damaged, the manufacturer, 

one of its service agents or a similarly qualified 

person must replace it in order to avoid hazard.

14.  This water fountain must be positioned so the 

plug is accessible.

15.  Disconnect the plug from the outlet when not 

in use.

16.  Remove power plug or disconnect from main 

power source before servicing the appliance.

17.  Warranty will be voided if installation is not 

carried out as detailed in this instruction manual.

18.  The compressor motor is equipped with an 

automatic reset protector which will disconnect 
the motor from the line in case of an overload.

IMPORTANT INFORMATION ABOUT GROUNDING

• 

To provide additional protection from the risk of shock, this unit MUST be connected to a  
residual-current device (RCD) outlet at all times. Use of an extension cord will void any warranties.

• 

This appliance must be grounded. Improper use of the grounding plug can result in a risk of 
electric shock, causing serious injury and possibly death.

• 

This appliance is equipped with a power cord having a grounding wire with a grounding plug and 
must be connected into a properly-grounded, polarised outlet.

• 

Consult a qualified electrician if the grounding instructions are not completely understood, or if 

doubt exists as to whether the appliance is properly grounded. If the wall outlet is a standard, 
2-prong outlet, it is your personal responsibility and obligation to have it replaced with a properly-
grounded, 3-prong wall outlet.

• 

Do not under any circumstances cut or remove the third (ground) prong from the power cord plug. 
Do not use an adapter plug with this appliance.

Содержание WM4F

Страница 1: ...Your Partner in Cool Usage and Care Manual Models WM4F WM4SS WM5 WM5SS WM SERIES ...

Страница 2: ...ympathetic The refrigerant flow is controlled by a capillary tube which has no moving parts WM4 WM5 R134a 125g Water Flow Controls The bubbler is rated to supply 1 7 L m at mains water pressure of between 140 and 700 kPa Water Connections Water Inlet 1 2 Male B S P Water Outlet 40mm Female P V C Socket Thermostat Control The thermostat is factory set Electrical 220 240 V 50 60 Hz Weight Packed WM4...

Страница 3: ...erson must replace it in order to avoid hazard 14 This water fountain must be positioned so the plug is accessible 15 Disconnect the plug from the outlet when not in use 16 Remove power plug or disconnect from main power source before servicing the appliance 17 Warranty will be voided if installation is not carried out as detailed in this instruction manual 18 The compressor motor is equipped with...

Страница 4: ...nd AS NZS 3500 2 Pipe jointing is a trade skill and Aqua Cooler recommends this process is performed by qualified personnel only 1 Ensure proper ventilation by allowing 75 mm clearance on each side of the fountain 2 Minimum water pressure is 100 kPa and maximum is 700 kPa 3 Install a 40 mm waste trap onto the waste outlet on the rear of the fountain not supplied 4 Water in connection is secured vi...

Страница 5: ...t cement is applied in full even coats to all applicable surfaces 5 Follow the direction line in figure 1 to connect the PVC pipe to the full depth of the socket and hold the bond joint in position for at least 30 seconds 6 Do not disturb for 5 minutes and allow 24 hours curing before testing See Figure 2 Aqua Cooler suggests using PVC priming fluid to prime PVC pipe prior to application of PCB pi...

Страница 6: ...l should be used Aqua Cooler recommends the water fountain is cleaned every month ensuring there is no blockage in the condenser or in the back of the unit Please remove all potentially harmful factors to prevent any scratch or damage to the unit If customers require the unit s spare parts information please contact the Aqua Cooler Service Department for further assistance The direct line is locat...

Страница 7: ...7 MARKS Spec No WMTS 105 2016 SAI GLOBAL WMK26317 Lic No The appliance is comply with applicable ACMA regulatory arrangements Regulatory Compliance Mark and WaterMark WMTS 105 2016 ...

Страница 8: ...8 Your Partner in Cool EXPLODED DIAGRAM ...

Страница 9: ...8 Cold tank assembly SPM8 9 Evaporator SPM9 10 Cold thermostat SPM10 11 Condenser SPM11 12 Power cord SPM12 13 Rubber feet SPM13 14 Compressor SPM14 Description Code 15 Pressure reduce SPM15 16 Motor SPM16 17 Condenser cover SPM17 18 Fan blade SPM18 19 Condenser bracket SPM19 20 Condenser SPM20 21 Rear panel SPWM21 22 Frame SPWM22 23 Front panel SPWM23 24 Mat SPWM24 25 Plug SPWM25 26 Dryer SPWM26 ...

Страница 10: ...ssure is higher than 700 kPa and a pressure limiting valve is not installed 4 Where the unit is not installed as per installation instructions found within the supplied user manual 5 The warranty does not cover defects occasioned by misuse alterations accident or where the water cooler has been stored on its side FOR ANY CLAIM UNDER THIS WARRANTY PLEASE CONTACT AQUA COOLER PTY LTD PHONE 61 02 9721...

Страница 11: ...Your Partner in Cool ...

Страница 12: ...Your Partner in Cool Phone Numbers Sales 1300 278 226 Service 1800 278 226 Address U14 2 12 Knobel Court Shailer Park QLD 4128 Internet www aquacooler com au info aquacooler com au ...

Отзывы: