background image

Remove power plug or disconnect from the main power source before servicing the
appliance.

Warranty will also be voided if installation is not carried out as detailed in this
instruction manual.

Important Information About Grounding 

To provide additional protection from the risk of shock, this unit MUST be connected
to a residual current device (RCD) outlet at all times. Use of an extension cord will
void any warranties.

This appliance must be grounded. Improper use of the grounding plug can result in a
risk of electric shock, causing serious injury and possibly death.

This appliance is equipped with a power cord having a grounding wire with a
grounding plug and must be connected into a properly-grounded, polarised outlet.

Consult a qualified electrician if the grounding instructions are not completely
understood, or if doubt exists as to whether the appliance is properly grounded

Do not under any circumstances cut or remove the third (ground) prong from the
power cord plug. Do not use an adapter plug with this appliance.

Installation Instructions 

Important information about the unit and operation: 

1. The underbench chiller is not intended for outdoor use.
2. All service work to be carried out by authorised Aqua Cooler service agents only.

Failure to do so will void the warranty on the water cooler.

3. Warranty will also be voided if installation is not carried out as detailed in the Aqua

Cooler installation instructions.

4. Please ensure the chiller is not tilted during transportation. If the chiller is tilted,

please leave the chiller in upright position for at least 30 minutes before turning on
the chiller.

5. If the power cord is unplugged, please wait for at least 3 minutes to re-plug the power

cord to prevent initiating the overload protector of compressor.

6. The compressor motor is equipped with an automatic reset protector which will

disconnect the motor from the line in case of an overload.

Unpacking the water fountain: 

1. Place the machine on a hard, flat surface. Make certain the unit is level. The unit

should not be close to sources of heat otherwise performance may be affected.

2. Please inspect the carton and water cooler for evidence of rough handling and

concealed damage. Damage claims should be filed with the carrier.

Содержание H2O NOW

Страница 1: ...1 H2O NOW CHILLER Usage and Care Manual...

Страница 2: ...2 Product Diagram Metal version and Plastic version...

Страница 3: ...e plugged into the same outlet Be sure that the plug is fully inserted into the outlet Do not run the power cord over carpeting or other heat insulators Do not cover the power cord Keep the power cord...

Страница 4: ...iance Installation Instructions Important information about the unit and operation 1 The underbench chiller is not intended for outdoor use 2 All service work to be carried out by authorised Aqua Cool...

Страница 5: ...outlet 8 Connect the mains water to the underbench chiller via 1 4 pipe ensuring that the supplied mains pressure relief valve is placed inline between the mains water source and the water chillers wa...

Страница 6: ...dditional lubrication 5 The fan motor on this unit seldom needs oiling If required a few drops of SAE 10 oil should be used 6 Aqua Cooler recommends the water fountain is cleaned every month ensuring...

Страница 7: ...g is still available Check there is no isolation valves on the plumbing pipework that has been closed off preventing water being provided to the chiller The faucet is faulty and is not letting water t...

Страница 8: ...panel 1 H2OPC SP13 4 Compressor 1 H2OPC SP4 14 knob 1 H2OPC SP14 5 Cold thermostat 1 H2OPC SP5 15 The ship type switch 1 H2OPC SP15 6 Hang plate 1 H2OPC SP6 16 Rear panel 1 H2OPC SP16 7 Indicator lig...