Aqua Computer high flow NEXT Скачать руководство пользователя страница 8

high flow NEXT

6.

6.

6.

6. Overview pages (aquasuite)

Overview pages (aquasuite)

Overview pages (aquasuite)

Overview pages (aquasuite)

Current   sensor  readings   and  diagrams   from   all  supported   devices   can   be   dis-
played in overview pages. For each device a pre-configured overview page is au-
tomatically generated the first time the device is connected to the PC. These pages
can be individually modified and new pages can be created. Within one overview
page, data from all connected devices can be accessed.

6.1.

6.1.

6.1.

6.1. Desktop mode

Desktop mode

Desktop mode

Desktop mode

Each overview page can be displayed directly on your desktop. You can enable
desktop mode for an overview page by clicking the monitor symbol in the list of
overview pages. Desktop mode can only be enabled for one overview page at a
time. With desktop mode enabled, elements of the overview page may cover pro-
gram  symbols  on  your  desktop,   but mouse  clicks  are  transmitted  to  underlying
desktop symbols. 
If a overview page is unlocked for editing while desktop mode is active, the page
will be displayed in the aquasuite window for editing and the current desktop will
be displayed as background for your convenience. 

6.2.

6.2.

6.2.

6.2. Creating new overview pages and activating edit mode

Creating new overview pages and activating edit mode

Creating new overview pages and activating edit mode

Creating new overview pages and activating edit mode

In  order   to create  a new  overview page,  click   the  plus  symbol  in  the  headline
“Overview pages”. 
Existing overview pages can be unlocked for editing by clicking lock symbol in the
page listing. 

6.3.

6.3.

6.3.

6.3. Adding new elements

Adding new elements

Adding new elements

Adding new elements

If the currently selected overview page is unlocked for editing, a plus symbol is dis-

played in the top right corner of the screen. Click the symbol to add a
new element to the page and select the desired element from the follow-
ing list. All available data is displayed in a tree diagram, click the arrow

symbols to access individual items. 
Confirm your selection by clicking the check symbol in the bottom  right corner.
The new element will be displayed in the upper left corner and the configuration
window is displayed. Configure the element as described in the next chapters.

- 8 -

Aqua Computer GmbH & Co. KG

© 2020

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Содержание high flow NEXT

Страница 1: ...r and installation manual high flow NEXT aquasuite version X 27 Current as of October 2020 All information contained in this manual is subject to change without prior notice All rights reserved 2020 A...

Страница 2: ...ding new elements 8 6 4 Editing existing elements 9 6 5 Values and names 9 6 6 Detailed data elements 9 6 7 Log data chart 9 6 8 User defined Images text drawing elements 9 6 9 Export and import of ov...

Страница 3: ...19 13 1 Device information 19 13 2 Factory defaults 19 13 3 Basic RGBpx settings 19 13 4 USB power supply 19 13 5 aquabus configuration 19 13 6 Standby behavior 20 13 7 Firmware update and language se...

Страница 4: ...malfunction of this product can reasonably be expected to re sult in personal injury Aqua Computer GmbH Co KG customers using or selling this product for use in such application do so at their own ri...

Страница 5: ...vices aquaero 6 XT 53146 53206 53250 53251 53262 53263 aquaero 6 PRO 53145 53253 aquaero 6 LT 53234 aquaero 5 XT 53089 53125 53249 aquaero 5 PRO 53090 53252 aquaero 5 LT 53095 4 3 4 3 4 3 4 3 Connecto...

Страница 6: ...e for devices with miniature connector 53295 Utilization as alarm output The header can be connected to the power switch header of the motherboard us ing an additional specialized cable 53216 not incl...

Страница 7: ...the right side shows the details of the current ly selected list element The list can be hidden or restored by clicking the arrow symbol in the upper left corner List elements may be minimized or max...

Страница 8: ...suite window for editing and the current desktop will be displayed as background for your convenience 6 2 6 2 6 2 6 2 Creating new overview pages and activating edit mode Creating new overview pages a...

Страница 9: ...available Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chr...

Страница 10: ...To export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import pag...

Страница 11: ...can be configured To add data to the chart first select the Data sources tab in the chart configura tion and select a data set to be displayed If no data sources are available you will have to config...

Страница 12: ...anual data export Manual data export Saved data can be exported from the data log into a XML file To do so select Analyze data below the Data log headline in the listing Select the Data sources tab in...

Страница 13: ...rate can be displayed either in liters or gallons per hour please see chapter 9 1 for details If necessary the flow rate can be calibrated manually 8 3 8 3 8 3 8 3 Water temperature Water temperature...

Страница 14: ...sors Software sensors Software sensors The last eight sensors in the list are software sensors and can be used to transmit sensor data that is not physically available to the high flow NEXT from the c...

Страница 15: ...display settings Display brightness and automatic change of the displayed screen can be config ured As with all OLED displays the brightness of active pixels will reduce over time For a homogeneous we...

Страница 16: ...fects can be configured to modify effect parameters depending on current sensor data In total up to eight LED controllers two for integrated lighting six for external components can be configured 10 2...

Страница 17: ...te configuration can also be used to modify existing audio filters and define custom audio filters 10 7 10 7 10 7 10 7 AMBIENTpx effect AMBIENTpx effect AMBIENTpx effect AMBIENTpx effect The AMBIENTpx...

Страница 18: ...be raised While an alarm condition is detected the device display will permanently show a corresponding information screen Additionally the RGBpx illumination can be configured to flash red On the al...

Страница 19: ...n In default configuration power consumption is limited to a maximum current of 0 5 Amps This value complies with the maximum allowed current according to the USB spec ification If a large number of L...

Страница 20: ...utomatically closed 14 14 14 14 Playground aquasuite Playground aquasuite Playground aquasuite Playground aquasuite Click the entry Playground to configure Virtual Software Sensors global profile mana...

Страница 21: ...ending on running applications During configura tion of the respective rule in the aquasuite the application to be configured must already be running The application selection within the aquasuite wil...

Страница 22: ...cording through third parties is possible Use the data export feature for data that you want to publish publicly and are allowed to do so only 15 2 15 2 15 2 15 2 Data access Data access Data access D...

Страница 23: ...hen done 16 3 16 3 16 3 16 3 Units Units Units Units Select the units to be used for temperature and flow values from the drop down menus After changing these settings the software will have to be res...

Страница 24: ...ersion It is not mandatory that each device has a corresponding update service period For update service validation the aquasuite requires an in ternet connection After successful validation a file co...

Страница 25: ...tact with coolant or water 17 3 17 3 17 3 17 3 Waste disposal Waste disposal Waste disposal Waste disposal This device has to be disposed of as electronic waste Please check your local regulations for...

Отзывы: