![AQESO U62GH Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/aqeso/u62gh/u62gh_manual_2957896004.webp)
1).Press the START/STOP button, all symbols appear on
the display. then 0 flash for 2 seconds, the pump begins to
inflate the cuff, the rising pressure in the cuff is shown on
the display.
2).After the suitable pressure has been reached, the pump
stops and the pressure gradually falls, The cuff pressure is
displayed, In case that the inflation is not sufficient, the
device automatically re-inflates to a higher pressure.
3).When the device detects a pulse, the heart symbol
on the display starts to flash.
4).When the measurement has been completed, the
systolic, diastolic and pulse rate will appear on the display
.
Wrist Electronic
Blood Pressure Monitor
Model:U62GH
Table of Contents
Introduction
Safety Information
Safety Information
Safety Information
Safety Information
Introduction- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
Safety Information- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Product Structure- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9
Each Of Component- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Battery Installation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
Setting Mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
Proper Use Of The Unit- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 6
About Blood Pressurp- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 23
Exceptional Situations- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Care And Maintenance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 28
Specification- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 31
Warranty Information- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 33
Emc Declaration- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 35
Thank you for purchasing the Wrist Blood PressureMonitor. Please
read the manual carefully before you use the unit, and keep the manual
well after using.
The unit is compact and easy to use, adopts the oscillometric principle.
It measures your blood pressure advanced " Intellisense" for comfortable
controlled inflation without the need of pressure presetting or reinflation.
This unit is only applied for the adult reinflation. This unit is only applied for
the adult
2x199 sets memory function, each measurement result will be
displayed on the screen, and automatically stored.This unit has blood
classification index, could easy to check your classification index, could
easy to check your blood pressure.
INTENDED USE
This automatic blood pressure monitor intends to measure the systolic
pressure, diastolic pressure and pulse rate through wrist. It's expected to
be used at home or in the hospital, intended for people over 12 years old.
Contraindication
:
This product can't be used in patients who is with severe heart insufficien-
cy to avoid suffocation and death. This product is not suitable for infants
and children.
To assure the correct use of the product, basic safety measures should
always be followed including the warning and the caution listed in the
instruction manual :
Safety Information
Each Of Component
Battery installation
Battery installation
Product Structure
Setting Mode
Setting Mode
Properuse Of The Unit
Setting Mode
Properuse Of The Unit
Properuse Of The Unit
Properuse Of The Unit
Properuse Of The Unit
Properuse Of The Unit
About Blood Pressure
About Blood Pressure
Properuse Of The Unit
Symbol descriptions
The following symbols may appear in this manual, on the label,on the
device, or on it's accessories. Some of the symbols represent standards
and compliances associated with the device and its use.
WARNING: This alert identifies hazards that may cause serious
personal injury or death.
CAUTION: This alert identifies hazards that may cause
minor personal injury, product damage, or property damage.
Type BF applied part
Manufacturer
Authorized Representative in the European Community
CE Mark: conforms to essential requirements of the Medical
Device Directive 93/42/EEC.
DISPOSAL: Do not dispose this product as unsorted municipal
waste. Collection of such waste separately for special treatment
is necessary.
Direct current
Follow instructions for use
CAUTION: Consult accompanying documents
Specifies serial number
SN
Those who have arrhythmia, diabetes, blood circulation or apoplexy
problem, please use under the physician' s instruction.
Contact your physician for specific information about your blood
pressure. Self diagnosis and treatment which use measured results
may be dangerous. Follow the instructions of your physician or licensed
healthcare provider.
Please placeon a high place where children can't be touched.
No modification of this equipment is allowed.
Do not modify this equipment without authorization of the manufac-
turer.
If this equipment is modified, appropriate inspection and testing
must be conducted to ensure continued safe use of equipment.
The cuff hose around neck may cause the suffocation.
The swallowing of small part like packaging bag, battery,battery
cover and so on may cause the suffocation.
Please don't use a dilution agent, alcohol or petrol to clean from a high
place. Use the right cuff, otherwise it can not Never leave any low battery
in the battery compartment work.
Never leave any low battery in the battery compartment since they
may leak and cause damage to the unit.
Please take off the battery if you won't use in 3 months
Replace the new batteries if the unit display a low battery symbol.
Do not mix the old and new batteries.
Do not use a cellular phone near the unit. It may result in operational
failure.
Please avoid using in high radiant area in order to make your measur-
ing data correctly.
Do not use the equipment where flammable gas (such as anesthetic
gas, oxygen or hydrogen) or flammable liquid (such as alcohol) are
present.
Classification
WARNING:
1. Internally powered equipment;
2. Type BF applied part; .
3. Protection against ingress of water or Particulate matter: IP21;
4. Not category AP /APG equipment;
5. Mode of operation:intermittent operation.
The user must check that the equipment functions safely and see that
it is in proper working condition before being used.
Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facillities.Contact you local
government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the groundwater and
get into the food chain, damaging your health and well-being.
1.5X2AAA
alkaline batteries
NOTE:
Please read the warranty information in the end of the manual carefully.
BATTERY
STORAGE BOX
Battery Installation And Replacement
Low battery and replacement
When power on, the low battery symbol will display once the unit start
to work, and you must replace with new batteries, otherwise the unit can' t
work.
Battery type and replacement
Please use 2pcs AAA identical 1. 5V alkaline batteries.
Do not use the batteries beyond their expiry date.
Please remove the batteries if you do not need to use for long time.
Dispose of the battery in accordance with all federal, state and local laws.
To avoid fire and explosion hazard, do not burn or incinerate the battery.
WARNING
1. Push the hook on the bottom of the battery cover
as picture.
2. Insert two 1.5V "AAA" batteries in the battery
compartment.
Place the batteries "+" and "-" in the right in the right.
3. Pull the battery cover to the main unit.
When the battery cover close tightly, could hear
"Ka-ka".
Press button MEM when power off, the
screen will display or , press
button MEM , it will be changed between
and , press button SET when you
confirm the user, then it will enter into the
Year Setting mode.
HOW TO SET USER
Continue to above step, the screen will display
and flash 20XX
,
the last digit of the year will
increase 1 when press button MEM each time,
you could choose from 2020 to 2099.Press
button SET when you confirm the year, then it
will enter into the Month and Date Setting mode.
YEAR SETTING
Continue to above step, the screen will display
xMxxD and XX-XX,and keep flashing on
month ,the digit will increase 1 when press
button MEM each time
,
you could choose
from 1 to 12.Press button SET when you
confirm the month, then it will set the date.
Same as the month setting ,each time you
press button MEM ,the digit will keep changing
from 01 to 31.Press button SET when you
confirm the date, then it will enter into the Time
Setting mode.
MONTH AND DATE SETTING
User 1
Year Setting
Month Setting
Date Setting
User 2
Continue to above step, the screen will display
xMxxD and XX:XX
,
and keep flashing on the
digits of hour
,
the digit will increase 1 when
press button MEM each time
,
you could
choose from 0 to 23.Press button SET when
you confirm the hour, then the digits of minute
start to flash ,same as the hour setting ,each
time you press button MEM ,the digits will keep
changing from 00 to 59.Press button SET when
you confirm the minute, then the total setting is
completed.
Note:
If the battery has been retracted for 30s and
continues to extend, you need to set the date
and time
TIME SETTING
Hour Setting
Minute Setting
Pre-measurement
Relax for about five to ten minutes prior to the measurement Avoid eating,
drinking alcohol, smoking, exercising and bathing for 30 minutes before
taking a measurement. AIll these factors will influence the measurement
result.
Remove any garment that fits closely to your wrist.
Always measure on the same wrist(normally left).
Take measurement regularly at the same time of every day, as blood
pressure changes even during the day.
Common factors of wrong
All efforts by the patient to support their arm can increase All efforts by the
patient to support their arm can increase.
Make sure you are in a comfortable ,relax position and do not activate any
of the muscles in the measurement arm during measurement.Use a
cushion for support if necessary.
If put the wrist lower or higher than the heart, a false reading will be
obtained.
Note:
Only use clinically approved cuffs!
A loose cuff or a exposed bladder causes false reading.
With repeated measurements , blood accumulates in the arm which can
lead to false reading.
Consecutive blood pressure measurements should be repeated after 1
minute pause or after the arm has been held up in order to allow the
accumulated blood to flow away.
1. Roll up sleeve. Make sure your sleeve is not rolled
up too tightly on your arm. This may constrict the flow
of blood in your arm.
2. Wrap the cuff directly against your skin,hold the
bottom part of the cuff and wrap it around the wrist so
it fits comfortably and securely around your wrist as
picture show.
3. Sit in a chair and take an erect body posture, make
the erect body posture, make the monitor at the same
level as your heart.
4. Press the START/ STOP button, the monitor will
measure your blood pressure automatically, Please
keep still when the monitor works.
Measurement
Measuring Procedure
About Blood Pressure
1cm
5).The measurement readings remain on the display until you switch off
the device. If no button is pressed for a period of 3 minutes, the device
switches off itself in order to save the power.
NOTE:
The symbol will be displayed along with the reading if the irregular heartbeat
is detected during the measurement.
Note:
If it is not possible to fit the cuff to your left wrist, it can also be placed on
the right. However, all measurements should be made using the same
wrist.
Discontinuing a measurement
If it is necessary to interrupt a blood pressure measurement for any reason
(eg.the patient feels unwell) the START/STOP button can be pressed at any
time. The device immediately decrease the cuff pressure automatically.
Memory-recall of measurements
This blood pressure monitor automatically stores 2x199 sets measurements
value, the oldest record will be replaced by the latest measurement value when
more than 199 sets each user.
Read memory record
Press the MEM button when power off, the latest 3 times average value will be
shown, press the MEM button again, the last measurement value will be shown,
as well as subsequent measurements can be display one after the other by
pressing the MEM button each time.
Memory -clear of measurements
If you are sure that you want to permanently
remove all stored memories. Press the SET button
for 7 times until CL appears when power off, press
the START/STOP button, CL will flash for 3 times
to clear all the memories. After this press the MEM
button again, M and “no” will be shown on the
display which mean that no memory in store.
Blood pressure is the pressure exerted the arteries.
The systolic blood pressure value represents the blood pressure produced
by contraction of the heart muscle.
The diastolic blood pressure value represents the blood pressure
produced by relaxation of the heart muscle.
Systolic blood pressure
Diastolic blood pressure
Contraction of the
heart muscle
Extrude blood
Pressure increased
to the blood vessel
Hight pressure
Relaxation of the
heart muscle
Blood return heart
Pressure decreased
to the blood vessel
Lower pressure
Optimal blood
pressure (target value)
Normal blood pressure
High normal value
Mild hypertension
Moderate hypertension
Severe hypertension
Diastolic blood
pressure
(mmHg)
Systolic blood
pressure
(mmHg)
According to the blood pressure classification by the WHO/ISH.
SYS lower than 100mmHg is considered as hypotension.
Too low
Too hight
Correct position
MEM
SET
START
STOP
10 Pulse Rate
11 Blood Pressure Classification
5
1 User
2 Year/month/date/time
3 Systolic Blood Pressure
4 Irreqular Heart Beat
5 Diastolic Blood Pressure
6 Memory Times
7 Pulse
8 Memory Symbol
9 Low Battery
1
2
3
4
6
UNIT
DISPLAY
3
4
5
8
9
10
11
1
2
7
MEM
SET
START
STOP
SET
START
STOP
MEM
6
2/41
3/41
4/41
6/41
5/41
7/41
8/41
10/41
9/41
11/41
12/41
14/41
13/41
15/41
16/41
18/41
17/41
19/41
20/41
22/41
21/41
23/41
24/41
1
LCD
Display
2
Start/Stop
Button
3
SET
Button
4
Memory
Button
5
Battery
Cover
6