Apxalarm 6150RFAPX2 Скачать руководство пользователя страница 3

 

-

 3

 

-

 

An example of an installation using two 6150RFAPX2 
Keypad/Transceivers with 2-Way Wireless Devices (e.g., 
5828V) on Two Partitions is shown below: 

 

 
 
 
 

 

 
 
 
 

 

Settings

 

6150RFAPX2 #1

 

6150RFAPX2 #2

 

Keypad:

 

Must be assigned to 

Partition 1 in the 

control panel

 

Must be assigned to 

Partition 2 in the 

control panel 

House ID:

 

Match Partition 1 

House ID in the 

control panel and 

House ID in Wireless 

Device

 

Match House ID in 

Wireless Device

 

House ID 

Source:

 

System

 

Local

 

Receiver 

Enable:

 

On

 

Off

 

Transmitter 

Enable:

 

On

 

On

 

PROGRAMMING THE 6150RFAPX2 

The 6150RFAPX2 is shipped with pre-programmed default 
values. Later in these instructions are diagrams showing the 
wireless keys' loops and their default functions.  Regardless of 
which wireless key you use (even if it is one not shown), loops 
1-4 are defaulted for all eight devices as 

shown.  These values may be changed to suit the installation. 

Entering Program Mode 

Press the [1] and [3] keys simultaneously for a few seconds, 
within 30 seconds after applying power.  The keypad beeps 
three (3) times, and two dashes and two zeroes flash 
alternately in the upper left-hand corner of the display.  If 
any other numbers or letters flash in the display, press the 
[

] key. 

Note: 

The keypad will not enter programming mode if the 

system has been armed before the 6150RFAPX2 was 
powered up or down. 

 

 

Pressing the [1] and [3] keys 30 seconds or more after 

applying power allows you to enter the User mode. This 

mode allows you to enable and disable individual local 

wireless keys (useful if, e.g., a user accidentally loses a 
wireless key).  Refer to the User Guide for instructions.  

Programming Operations 

Once you have entered the Program mode, you may move to 
any program address simply by entering the program address 
number. The 6150RFAPX2 will automatically exit the 
Program mode if no keys are pressed for 90 seconds. While in 
the Program mode: 

 

Pressing the [

] key stores the information displayed, then 

moves you to the next prompt, and the keypad beeps twice. 

 

Pressing the 

[#

] key erases the current information and 

moves you back so you may enter the correct information. 

Enter a program address (e.g., press 

[1]

 for Keypad Address; 

[2]

 for Receiver Address) to set the parameters in the 

6150RFAPX2.The following chart lists the program 
addresses, the keypad display, and the choices.

Program 

Address

 

Description

 

Display

 

Choices

 

Default 

1

 

Keypad Address

 

cA

 

01-31

 

31 

2

 

Receiver Address

 

rA

 

00-30

 

00 

3

 

House ID

 

HI

 

01-31

 

10 

4

 

House ID Source

 

hS

 

1 = System   
0 = Local

 

1 System 

5

 

Wireless Key Editing

 

d-

 

Enter Existing Device Number

 

 

6

 

Receiver Enable

 

rE

 

1 = On  0 = Off

 

1 Enable 

7

 

Transmitter Module Enable

 

tE

 

1 = On  0 = Off

 

1 Enable 

8

 

Wireless Key Auto Enroll

 

d*

 

Enter Serial Number

 

 

8 then 2

 

Wireless Key User Code

 

u4

 

Enter 4-Digit User Code

 

 

8 then 4

 

Wireless Key Loop Function

 

Ln

 

Enter Loop Number then Function 
(See 

Wireless Key Function Chart

)

 

Loop 2  1 (Disarm) 
Loop 3  2 (Arm Away) 
Loop 4  3 (Arm Stay) 

8 then 5

 

Wireless Key On-Board Relay 
Assignment

 

o-

 

Enter Loop Number then Relay 
Action

 

Loop 1  Close for 2 Seconds 

9

 

Restore Defaults

 

EE

 

1 = Restores Defaults 
Any Other Key = Does Not 
Restore Defaults

 

 

0

 

High Security Mode

 

En

 

1 = Enable; 0 = Disable

 

0 Disable 

* The keypad will display the next number that can be enrolled (i.e., “d3”) 

 

 When operating the system in High-Security mode, non-encrypted wireless keys will 

not

 function.  

 

CONTROL 

PANEL 

6150RFAPX2 

#1 

6150RFAPX2

#2 

Содержание 6150RFAPX2

Страница 1: ...to trip a garage door opener U U U UL L L L This feature is not intended for UL installations Activates relays programmed into the control panel Provides an End User mode to enable disable local wire...

Страница 2: ...ocal 6150RFAPX2 Application Guide The following guide outlines how to program the wireless keys RF receiver and the House ID in the 6150RFAPX2 for your installation Two 6150RFAPX2s are needed for this...

Страница 3: ...for instructions Programming Operations Once you have entered the Program mode you may move to any program address simply by entering the program address number The 6150RFAPX2 will automatically exit...

Страница 4: ...ng steps Step Action Display 1 Enter the Program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after removing the case...

Страница 5: ...rial number The keypad will beep three times Note If enrolling a wireless key 5804E in high security mode press all four buttons on the wireless key simultaneously Alternately flashes d with the devic...

Страница 6: ...alternately flashes the loop number and the relay action 10 Repeat step 9 for the rest of the loops 11 When all loops have been programmed for the wireless key press the key Flashes d followed by the...

Страница 7: ...key 1 Replace the battery in the wireless key 2 Replace the transmitter if the wireless key does not have a replaceable battery OC Open circuit Verify that the Data Out wire is connected properly 1C...

Страница 8: ...urning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed R...

Отзывы: