![Apxalarm 6150RFAPX2 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/apxalarm/6150rfapx2/6150rfapx2_installation-and-setup-manual_2957789003.webp)
-
3
-
An example of an installation using two 6150RFAPX2
Keypad/Transceivers with 2-Way Wireless Devices (e.g.,
5828V) on Two Partitions is shown below:
Settings
6150RFAPX2 #1
6150RFAPX2 #2
Keypad:
Must be assigned to
Partition 1 in the
control panel
Must be assigned to
Partition 2 in the
control panel
House ID:
Match Partition 1
House ID in the
control panel and
House ID in Wireless
Device
Match House ID in
Wireless Device
House ID
Source:
System
Local
Receiver
Enable:
On
Off
Transmitter
Enable:
On
On
PROGRAMMING THE 6150RFAPX2
The 6150RFAPX2 is shipped with pre-programmed default
values. Later in these instructions are diagrams showing the
wireless keys' loops and their default functions. Regardless of
which wireless key you use (even if it is one not shown), loops
1-4 are defaulted for all eight devices as
shown. These values may be changed to suit the installation.
Entering Program Mode
Press the [1] and [3] keys simultaneously for a few seconds,
within 30 seconds after applying power. The keypad beeps
three (3) times, and two dashes and two zeroes flash
alternately in the upper left-hand corner of the display. If
any other numbers or letters flash in the display, press the
[
✻
] key.
Note:
The keypad will not enter programming mode if the
system has been armed before the 6150RFAPX2 was
powered up or down.
Pressing the [1] and [3] keys 30 seconds or more after
applying power allows you to enter the User mode. This
mode allows you to enable and disable individual local
wireless keys (useful if, e.g., a user accidentally loses a
wireless key). Refer to the User Guide for instructions.
Programming Operations
Once you have entered the Program mode, you may move to
any program address simply by entering the program address
number. The 6150RFAPX2 will automatically exit the
Program mode if no keys are pressed for 90 seconds. While in
the Program mode:
•
Pressing the [
✻
] key stores the information displayed, then
moves you to the next prompt, and the keypad beeps twice.
•
Pressing the
[#
] key erases the current information and
moves you back so you may enter the correct information.
Enter a program address (e.g., press
[1]
for Keypad Address;
[2]
for Receiver Address) to set the parameters in the
6150RFAPX2.The following chart lists the program
addresses, the keypad display, and the choices.
Program
Address
Description
Display
Choices
Default
1
Keypad Address
cA
01-31
31
2
Receiver Address
rA
00-30
00
3
House ID
HI
01-31
10
4
House ID Source
hS
1 = System
0 = Local
1 System
5
Wireless Key Editing
d-
Enter Existing Device Number
6
Receiver Enable
rE
1 = On 0 = Off
1 Enable
7
Transmitter Module Enable
tE
1 = On 0 = Off
1 Enable
8
Wireless Key Auto Enroll
d*
Enter Serial Number
8 then 2
Wireless Key User Code
u4
Enter 4-Digit User Code
8 then 4
Wireless Key Loop Function
Ln
Enter Loop Number then Function
(See
Wireless Key Function Chart
)
Loop 2 1 (Disarm)
Loop 3 2 (Arm Away)
Loop 4 3 (Arm Stay)
8 then 5
Wireless Key On-Board Relay
Assignment
o-
Enter Loop Number then Relay
Action
Loop 1 Close for 2 Seconds
9
Restore Defaults
EE
1 = Restores Defaults
Any Other Key = Does Not
Restore Defaults
0
High Security Mode
✝
En
1 = Enable; 0 = Disable
0 Disable
* The keypad will display the next number that can be enrolled (i.e., “d3”)
✝
When operating the system in High-Security mode, non-encrypted wireless keys will
not
function.
CONTROL
PANEL
6150RFAPX2
#1
6150RFAPX2
#2