APW Wyott HFW-1DS Скачать руководство пользователя страница 23

2M-Z24235 Owners Manual for Built-In  Hot Food W

ell W

armers 

PARTS LIST: HFW-4S, HFW-4DS

21

Model: Hot Food Wells  HFW-4S, HFW-4DS

Fig No

Part No

Description

Qty

Application

1

P2-31869

SCREEN DRAIN ASSY WARMER

4

DRAIN UNITS

2

WS-503893

PAN ASSY

1

HFW-4S T-STAT & INFINITE

3

WS-55741

PAN W/O DRAIN

4

HFW-4S T-STAT & INFINITE

WS-53201

PAN W/DRAIN

HFW-4S T-STAT & INFINITE, DRAIN

WS-55742

PAN W/DRAIN

HFW-4S T-STAT & INFINITE, DRAIN, MANIFOLD

3

HFW-4S T-STAT & INFINITE, DRAIN, MANIFOLD, AF

4

2V-35609

VALVE 1 IN GATE BRONZE

1

MANIFOLD UNITS

5

WS-503713

PROBE ASSY, SS AUTOFILL WRMR

1

AUTOFILL UNITS

6

2K-48198

ELBOW 3/8 X 90DEG BRASS

1

AUTOFILL UNITS

7

2K-48197

NIPPLE 3/8 NPT X 2 BRASS

1

AUTOFILL UNITS

8

2V-47650

VALVE ANTISYPHON 3/8

1

AUTOFILL UNITS

9

2K-47662

FTG STR BRS 3/8NPT X3/8IN

1

AUTOFILL UNITS

10

2C-46591

CLAMP HOSE 5/8

2

AUTOFILL UNITS

11

2K-31040

BUSHING HEYCO 7/8 OD

1

THERMOSTAT UNITS

12

WS-50131

TERM BLOCK KIT (RETRO 30131)

1

INFINITE & AUTOFILL UNITS

13

2C-41974

NUT 8-32 HEX 7/8 LONG ALU

2

AUTOFILL UNITS

14

2J-30385

LIGHT SIGNAL GLO DOT RED

2

INFINITE UNITS

2J-35687

LIGHT SIGNAL GLO DOT

T-STAT UNITS

15

P2-Z12591

PANEL, CONTROL

1

INFINITE UNITS NON-AF

P2-Z12584

PANEL, CONTROL

HFW-4S, T-STAT, DRAIN, MANIFOLD, AUTOFILL

16

P2-48290

BOX OUTLET

1

HFW-4S, T-STAT, DRAIN, MANIFOLD

P2-46685

BOX OUTLET

HFW-4S INFINITE, DRAIN, MANIFOLD

17

2T-38968

THERMO K TYPE

4

T-STAT UNITS

2T-46551

THERMO CTRL 96IN CAP

T-STAT UNITS w/ 96IN CAPILLARY

2T-45917

THERMO CTRL W/AUX WARMERS

T-STAT UNITS, AUTOFILL

2T-46551

THERMO CTRL 96IN CAP

T-STAT UNITS, AUTOFILL 96IN CAPILLARY

2E-30570

SWITCH INFINITE, 120V

4

INFINITE UNITS, 120V

2E-30562

SWITCH INFINITE, 240V

INFINITE UNITS, 240V

18

2R-Z24182

KNOB CONTROL ASSY WARMERS

4

INFINITE UNITS

2R-Z24181

KNOB ASSY

T-STAT UNITS

20

2E-46529

SOLENOID VALVE 1/4NPT 240

1

AUTOFILL UNITS

21

P2-40843

BRKT MTG THERMO INFINITE

2

T-STAT (SPLIT CONTROL)

P2-48285

BRKT THERMO

1

HFW-4S T-STAT, DRAIN, MANIFOLD, AUTOFILL

22

2E-306865

CONTROL LIQ LEVEL 208/240

1

AUTOFILL UNITS

23

2I-40034

GROMMET SCREW T4

4

AUTOFILL UNITS

24

2K-33996X

FTG FLEX CONDUIT 90X3/8

2

25

2I-Z12311

GASKET-FIBER WASHER

2

26

P2-35004

COVER BOTTOM

2

HFW-4S

27

P2-303359

SHROUD SIDE

2

HFW-4S

28

P2-48192

SHROUD REAR

1

HFW-4S

P2-303358

SHROUD FRONT

HFW-4S INFINITE & T-STAT

Содержание HFW-1DS

Страница 1: ...his manual includes material related to installation use cleaning and care Exploded view s as well as any available parts list s and wiring diagram s pertaining to the unit s covered by this manual ar...

Страница 2: ...oltage or gas type Normal Business Hours 8 00 a m to 4 30 p m Central Telephone 800 264 7827 Tech Service Option 2 Email TechService partstown com www apwwyott com WARRANTY EXCLUSIONS THE FOLLOWING WI...

Страница 3: ...his manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS INTRODUCTION...

Страница 4: ...is the lowest temperature setting PREHEAT is a continuous on setting Infinite switch controlled warmers are equipped with a hi limit device to prevent overheating The hi limit will self reset after th...

Страница 5: ...e use limitations and associated restrictions Operating instructions must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sa...

Страница 6: ...d start up of built in warmers MUST be performed by an authorized installation company 2 It is the responsibility of the installer to verify that this warmer installation is in compliance with the spe...

Страница 7: ...me jurisdictions may require an approved air gap or other back flow prevention device in the drain It is the responsibility of the plumber to determine such requirement to provide and properly install...

Страница 8: ...tely 30 minutes then set the control for the desired temperature Be sure to keep the warmer covered during preheat and operation AUTOFILL WARMERS 1 Autofill warmers sense water level by a sensor place...

Страница 9: ...NOT place food directly into the warmer 2 Check water level in wet operation warmer frequently during use Running warmers dry will lower the temperature of the food in the insert pan and may damage t...

Страница 10: ...r 2 Check water level in wet operation warmer frequently during use Running warmers dry will lower the temperature of the food in the insert pan and may damage the warmer 3 Alternating between wet and...

Страница 11: ...ans insets and other vessels are subject to a harsher environment APW Wyott Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless s...

Страница 12: ...rgent cleanser residue 4 Inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating elem...

Страница 13: ...overs accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control...

Страница 14: ...yott Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supply voltage must match voltage on war...

Страница 15: ...ns insets and other vessels are subject to a harsher environment APW Wyott Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless st...

Страница 16: ...2M Z24235 Owners Manual for Built In Hot Food Well Warmers EXPLODED VIEW HFW 1S HFW 1DS IL1905e 05 21 1 THERMOBULB 5 21 6 7 8 9 11 11 10 18 19 17 16 15 14 13 20 12 13 22 12 3 2 14...

Страница 17: ...5066 1 SHROUD WRAP ROHS HFW 1S 8 P2 45067 1 SHROUD FR ROHS HFW 1S 9 P2 45186 1 SHROUD BOT ROHS 10 5P 21709 1 SCREEN DRAIN WARMERS ALL 11 P2 30401 1 PAN W O DRAIN HFW 1S P2 30402 PAN W DRAIN HFW 1DS HF...

Страница 18: ...or Built In Hot Food Well Warmers EXPLODED VIEW PARTS LIST 16 3 6 7 8 9 10 5 1 37 3 2 4 16 15 21 24 25 17 25 24 23 22 11 12 13 14 18 20 10 19 AutoFill Units Only 26 29 27 28 30 34 36 35 T units only 3...

Страница 19: ...2J 30385 LIGHT SIGNAL GLO DOT RED 2 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS 15 P2 Z12288 PANEL CONTROL 1 T STAT INFINITE UNITS NON AF P2 Z12589 PANEL CONTROL 1 AUTOFILL UNITS 16 E7 4...

Страница 20: ...EMENT M227 T STAT 32 WS 50396 ELEM 120V 1200W 2 HFW 2S INFINITE 120V WS 50398 ELEM 240V 1200W M P HFW 2S INFINITE 240V 2N 46681UL ELEM 120V 1650W HFW 2S T STAT 120V 2N 303375UL ELEM HEATING 240V 1650W...

Страница 21: ...BLOCK KIT RETRO 30131 1 INFINITE AUTOFILL UNITS 13 2C 41974 NUT 8 32 HEX 7 8 LONG ALU 2 AUTOFILL UNITS 14 2J 30385 LIGHT SIGNAL GLO DOT RED 3 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS...

Страница 22: ...1 KIT ELEM PAN W ELEMENT 2 HFW 3S T STAT NARROW P2 WL0072 PAN ELEM ASSY MID 1 32 WS 50396 ELEM 120V 1200W 3 HFW 3S INFINITE 120V 2N 46681UL ELEM 120V 1650W HFW 3S T STAT 120V 33 WS 55707 COVER ELEM WA...

Страница 23: ...T SIGNAL GLO DOT RED 2 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS 15 P2 Z12591 PANEL CONTROL 1 INFINITE UNITS NON AF P2 Z12584 PANEL CONTROL HFW 4S T STAT DRAIN MANIFOLD AUTOFILL 16 P2...

Страница 24: ...NT 208 240 4 HFW 4S T STAT 32 WS 50398 ELEM 240V 1200W M P 4 HFW 4S INFINITE 240V 2N 303375UL ELEM HEATING 240V 1650W HFW 4S T STAT 240V 33 WS 55707 COVER ELEM WARMER 4 HFW 4S INFINITE UNITS WS 503842...

Страница 25: ...ITE AUTOFILL UNITS 13 2C 41974 NUT 8 32 HEX 7 8 LONG ALU 2 AUTOFILL UNITS 14 2J 30385 LIGHT SIGNAL GLO DOT RED 2 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS 15 P2 Z12594 PANEL CONTROL 1...

Страница 26: ...LEM 240V 1200W M P 5 HFW 5S INFINITE 240V 2N 303375UL ELEM HEATING 240V 1650W HFW 5S T STAT 240V 33 WS 55707 COVER ELEM WARMER 5 HFW 5S INFINITE UNITS WS 503842 KIT ELEM PAN W O ELEMENT HFW 5S T STAT...

Страница 27: ...N 12847 0 030 MOD 300 DIAGRAM WIRIN ENG REL ECN 855 G UNLESS NOTED DEC TOL PART NAME USED ON DO NOT SCALE DWG ISSUE WAS Z H 60 50 SINGLE PHASE 15 0 13 0 8 7 7 5 8 7 7 5 4 2 1 3 1 16 14 15 13 12 11 TER...

Страница 28: ...ILOT LIGHT 4 11 7 8 12 14 2 H 2 1 L L P H1 H2 P L L 1 2 1 H H2 P 2 1 L L H1 H2 3 1 2 2 1 Z H 60 50 SINGLE PHASE 25 0 21 6 13 0 11 2 13 0 11 2 4 3 2 1 20 THREE PHASE 240 17 0 7 4 10 15 0 208 SK3024 WIR...

Страница 29: ...G ELEMENT 2 7 1 4 WIRE CONNECTOR 6 TERM BLOCK L1 L2 L3 OPTIONAL CORD WHITE FROM CORD BLACK FROM CORD GREEN FROM CORD PILOT LIGHT TERM BLOCK THERMOSTAT 3 PILOT LIGHT 3 L1 L2 L3 REV E P N 2M 48589 240 2...

Страница 30: ...L1 L2 L3 THREE PHASE PHASE SINGLE 50 60 HZ 14 5 14 5 9 8 17 8 17 8 11 3 23 8 27 5 WIRING DIAGRAM Thermostat Control Units TERM BLOCK THERMOSTAT 5 PILOT LIGHT 5 L1 L2 L3 REV D P N 2M 48604 HEATING ELEM...

Страница 31: ...CE DESCRIPTION PART NO ADAPTERS INSETS ADAPTER TOP convert 12 x 20 warmer to hold four 2 qt insets 21623 4 QT ROUND INSET w lid 20774 11 QT ROUND INSET w lid 20908 11 QT ROUND INSET w hinged lid 21057...

Страница 32: ...o wood counter up to 1 thick 22593 E Z Lock Extension Kits for UL Listed units approved for installation in wood counter tops One well units require one kit Two and three well units require two kits f...

Страница 33: ...2M Z24235 Owners Manual for Built In Hot Food Well Warmers NOTES...

Страница 34: ...265 Hobson St Smithville TN 37166 Telephone 800 527 2100 Printed in the U S A 2M Z24235 Rev 05 21 Specifications are subject to change without notice is a registered trademark of APW Wyott A Middleby...

Отзывы: